Decision No. 04/2003/QD-BXD of the Ministry of Construction on issuing the Vietnam Construction Standard TCXD VN 294: 2003 on electrochemical testing methods for reinforcement corrosion. This decision shall take effect fifteen days from the date of signature.
Key points
- The Vietnam Construction Standard TCXD VN 294: 2003 "Reinforced Concrete - Method for Electrochemical Testing of Reinforcement Corrosion" has been issued.
- This decision shall take effect fifteen days from the date of signature.
🌐 Social impact of this document
- Positive impact: This new standard helps to improve the quality of inspection and protection of reinforcement in concrete, reducing the risk of collapse of construction projects.
- Negative impact: Enterprises need to comply with the new regulations, which may increase costs for implementing inspection measures.
❓ Frequently asked questions
When does this standard apply?
This standard takes effect fifteen days from the date of issuance.
Who is responsible for enforcing this decision?
The Director of the Ministry's Office, the Department Heads of Science and Technology, the Institute Directors of Construction Science and Technology, and the Heads of related units are responsible for enforcing this decision.
What testing method does this standard specify?
This standard specifies the electrochemical testing method for assessing the corrosion potential of reinforcement in concrete.
When does this decision take effect?
This decision shall take effect fifteen days from the date of issuance.
Full text
Pursuant to …;
Regarding the issuance of the Vietnamese Construction Standard Male TCXD VN 294: 2003
''Reinforced Concrete - Method for Electrochemical Testing of Steel Corrosion Potential''
''Ability of Steel to be Corroded''
_________________
THE MINISTER OF CONSTRUCTION
||| On the basis of Decree No. 15/CP dated March 4, 1994 of the Government stipulating the functions, tasks, powers, and organizational structure of the Ministry of Construction.
Pursuant to the minutes of meeting number 139/BXD-KHCN dated October 10, 2002 of the Scientific and Technological Council for the acceptance of the standard ''Reinforced Concrete - Method for Electrochemical Determination of Steel Corrosion Activity in Concrete''.
Considering the proposal of the Director of the Science and Technology Department and the Director of the Institute of Science and Technology for Construction.
Pursuant to …;
Article 1 : Issued together with this Decision is 01 Construction Standard of Vietnam TCXD VN 294: 2003 ''Reinforced Concrete - Method for Electrochemical Testing of Steel Corrosion Potential''.
Article 2 ||| This Decision shall take effect fifteen days from the date of issuance.
Article 3 The Officials: Director of the Ministry's Office, Head of the Science and Technology Department, Director of the Institute of Construction Science and Technology, and Heads of related units are responsible for implementing this Decision./.