Circular No. 24/2017/TT-BTTTT stipulates National Technical Regulations on E-UTRA Base Station Equipment - Radio Access Part

Circular No. 24/2017/TT-BTTTT stipulates National Technical Regulations on E-UTRA Base Station Equipment - Radio Access Part, applicable to organizations and individuals producing and trading such equipment. This Circular takes effect from July 1, 2018.

文号24/2017/TT-BTTTT
文件类型Circular
发布机关Ministry of Science and Technology
签署人Trương Minh Tuấn — Bộ trưởng
更新23/06/2026
行业Post and Telecommunications
领域Uncategorized
发布日期17/10/2017
生效日期01/07/2018
失效日期01/07/2024
状态Expired
✦ 智能摘要

Circular No. 24/2017/TT-BTTTT stipulates National Technical Regulations on E-UTRA Base Station Equipment - Radio Access Part, applicable to organizations and individuals producing and trading such equipment. This Circular takes effect from July 1, 2018.

适用范围

Organizations and individuals producing and trading E-UTRA Base Station Equipment - Radio Access Part.

要点

  • shall comply with technical requirements concerning operational environment, unwanted emissions, adjacent channel leakage ratio (ACLR), spurious transmitter and receiver emissions, maximum base station output power, modulation characteristics, blocking characteristics, adjacent channel selectivity, narrowband rejection, indoor output power for protection of related channels.
  • shall comply with regulations regarding measurement methods and management.
  • shall be responsible for implementing this Circular.
  • shall not violate technical requirements concerning unwanted emissions, adjacent channel leakage ratio (ACLR), spurious transmitter and receiver emissions, maximum base station output power, modulation characteristics, blocking characteristics, adjacent channel selectivity, narrowband rejection, indoor output power for protection of related channels.
  • shall not violate regulations concerning measurement methods and management.

🌐 本文件的社会影响

  • Positive impact: Ensuring mobile service quality, reducing interference

❓ 常见问题

To which base station equipment does this technical regulation apply?

This Circular stipulates National Technical Regulations on E-UTRA Base Station Equipment - Radio Access Part.

When does this Circular take effect?

This Circular takes effect from July 1, 2018.

What technical requirements must organizations and individuals producing base station equipment comply with?

Organizations and individuals producing base station equipment must comply with requirements concerning operational environment, unwanted emissions, adjacent channel leakage ratio (ACLR), spurious transmitter and receiver emissions, maximum base station output power, modulation characteristics, blocking characteristics, adjacent channel selectivity, narrowband rejection, indoor output power for protection of related channels.

Are there regulations regarding measurement methods and management?

Yes, this Circular stipulates measurement methods and management for E-UTRA Base Station Equipment - Radio Access Part.

Who is responsible for implementing this Circular?

The Director of the Office, Heads of Science and Technology Departments, Heads of agencies and units under the Ministry of Information and Communications, Directors of Provincial Information and Communications Departments under the Central Government, and relevant organizations and individuals are responsible for implementing this Circular.

全文

MINISTRY OF INFORMATION AND COMMUNICATIONS
-------

SOCIALIST REPUBLIC OF VIET NAM
Independence - Freedom - Happiness
---------------

Number: 24/2017/TT-BTTTT

Hanoion 17 the 10 Pursuant to Decree No. 32/2019/NĐ-CP dated April 10, 2019 of the Government on assigning tasks, procurement or tendering for the supply of products and services using state budget from regular operating expenses;17

 

CIRCULAR

ISSUING THE NATIONAL TECHNICAL REGULATION ON EVOLVED UNIVERSAL TERRESTRIAL RADIO ACCESS (E-UTRA) BASE STATIONS (BS) - WIRELESS ACCESS PART

Pursuant to Decree No. 85/2019/NĐ-CP dated November 14, 2019 of the Government detailing the implementation of administrative procedures under the national single window mechanism, the ASEAN Single Window mechanism, and specialized inspection of goods for export and import;rime Minister cand the Technical Regulation dated June 29, 2006;

Pursuant to the Law on Telecommunications dated November 23, 2009;

Pursuant to the Law on Radio Frequency Wavelengths dated November 23, 2009;No. Radio Regulations dated November 23, 2009;

WHEREAS, Decree No. 127/2007/NĐ-CP dated August 1, 2007 of the Government detailing and guiding the implementation of certain provisions of the Law on Technical Standards and Regulations;

Pursuant to Decree No. 17/2017/NĐ-CP dated February 17, 2017 of the GovernmentDeputy ministers of ministerial-level agencies, The Minister of Information and Communications issues this Circular detailing the implementation of certain provisions of the Law on Competition and Rewards in the Information and Communications Sector.

Pursuant to the proposal of the Director of the Science and Technology Department,

The Minister of Information and Communications issues this Circular stipulating the National Technical Regulation on Evolved Universal Terrestrial Radio Access (E-UTRA) Base Stations (BS) - Wireless Access Part. The National Technical Regulation on Evolved Universal Terrestrial Radio Access (E-UTRA) Base Stations (BS) - Wireless Access Part is hereby issued together with this Circular (QCVN 110:2017/BTTTT).ng The Heads of the Office, Department of Science and Technology, Heads of agencies and units under the Ministry of Information and Communications, Directors of Provincial Departments of Information and Communications, and organizations and individuals concerned are responsible for implementing this Circular./.

Article 1. NATIONAL TECHNICAL REGULATION ON EVOLVED UNIVERSAL TERRESTRIAL RADIO ACCESS (E-UTRA) BASE STATIONS (BS) - WIRELESS ACCESS PART

Article 2. This Circular takes effect from July 1, 2018.

Article 3. National technical regulation on Evolved Universal Terrestrial Radio Access (E-UTRA) Base Stations (BS)

 


Place of Receipt:
- Ministries, agencies equivalent to ministries, and government agencies;
- People's Committees and Provincial Information and Communications Departments of provinces and centrally governed cities;
- Legal Documents Supervision Bureau (Ministry of Justice);
- Official Gazette, Government Portal;
- MINISTRY OF INFORMATION AND COMMUNICATIONS: The Minister and Deputy Ministers, Agencies and Units under the Ministry, Electronic Portal of the Ministry;
- To be filed: VT, KHCN (250).

THE MINISTER
(Signed)



TRUONG MINH TUN

 

QCVN 110:2017/BTTTT

2.1. Environmental Conditions

2.2. Technical Requirements

 

2.4.4. Support for Multi PLP

Chapter 1. GENERAL PROVISIONS

1.1. Scope of Application

1.2. Applicability

1.3. Referenced Documents

1.4. Terms and Definitions

dBc

Bandwidth

Chapter 2. TECHNICAL PROVISIONS

2.2.1. General Requirements

2.2.2. Unwanted Emissions within the Operating Band

2.2.3. Adjacent Channel Leakage Ratio (ACLR)

2.2.4. Spurious Transmitter Emissions

2.2.5. Maximum Output Power of the Base Station

2.2.6. Transmitter Modulation Characteristics

2.2.7. Spurious Receiver Emissions

2.2.8. Blocking Characteristics

2.2.9. Receiver Modulation Characteristics

2.2.10. Adjacent Channel Selectivity (ACS) and Narrowband Blocking

2.2.11. Indoor Output Power of the Base Station for Protecting the Adjacent UTRA Channel

2.2.12. Indoor Output Power of the Base Station for Protecting the Adjacent E-UTRA Channel

2.2.13. Indoor Output Power of the Base Station for Protecting the Co-Channel E-UTRA

2.2.14. Standard Selectivity Level

2.2.15. Radiation Emissions

3.1. Measurement Conditions

3.2. Interpretation of Measurement Results

3. MEASUREMENT METHODS

3.3. Essential Parameters for the Wireless Part

3.3.1. Unwanted Emissions within the Operating Band

3.3.2. Adjacent Channel Leakage Ratio (ACLR)

3.3.3. Spurious Transmitter Emissions

3.3.4. Maximum Output Power of the Base Station

3.3.5. Transmitter Modulation Characteristics

3.3.6. Spurious Receiver Emissions

3.3.7. Blocking Characteristics

3.3.8. Receiver Modulation Characteristics

3.3.9. Adjacent Channel Selectivity (ACS) and Narrowband Blocking

3.3.10. Indoor Output Power of the Base Station for Protecting the Adjacent UTRA Channel

3.3.11. Indoor Output Power of the Base Station for Protecting the Adjacent E-UTRA Channel

3.3.12. Indoor Output Power of the Base Station for Protecting the Co-Channel E-UTRA

3.3.13. Standard Selectivity Level

3.3.14. Radiation Emissions

ANNEX A (Provisions) Base Station Configuration

ANNEX B (Reference) Environmental Considerations

5. RESPONSIBILITIES OF ORGANIZATIONS AND INDIVIDUALS

5. RESPONSIBILITIES OF ORGANIZATIONS AND INDIVIDUALS

6. IMPLEMENTATION ORGANIZATION

ANNEX C (Reference) Measurement Diagrams

LIST OF REFERENCED DOCUMENTS

QCVN 110:2017/BTTTT contains technical provisions and measurement methods consistent with European Telecommunications Standards Institute (ETSI) standards EN 301 908-1 V11.1.1 (July 2016) and EN 301 908-14 V11.1.1 (May 2016).

QCVN 110:2017/BTTTT was compiled by the Post and Telecommunications Science and Technology Institute, reviewed by the Department of Science and Technology, and promulgated along with Circular No. 24/2017/TT-BTTTT dated October 17, 2017.

 

Foreword

This standard sets out technical requirements for Evolved Universal Terrestrial Radio Access (E-UTRA) base stations operating in the entire or any part of the frequency bands specified in Table 1.

Table 1 - Frequency Bands of Evolved Universal Terrestrial Radio Access (E-UTRA) Base Stations

 

2.1. Environmental Conditions

2.2. Technical Requirements

Chapter 1. GENERAL PROVISIONS

1.1. Scope of Application

E-UTRA Frequency BandDirectionFrequency Band of E-UTRA Base Station1Transmit2 110 MHz to 2 170 MHzReceive1 920 MHz to 1 980 MHz3Transmit1 805 MHz to 1 880 MHzReceive1 710 MHz to 1 785 MHz7Transmit2 620 MHz to 2 690 MHzReceive2 500 MHz to 2 570 MHz8Transmit925 MHz to 960 MHzReceive880 MHz to 915 MHz38Transmit and Receive2 570 MHz to 2 620 MHz40Transmit and Receive2 300 MHz to 2 400 MHz

This technical regulation applies to domestic and foreign agencies, organizations, and individuals engaged in production, import, business operations, and exploitation of equipment within the scope of this regulation on the territory of Vietnam.

ETSI TS 136 141 (V11.14.0) (01-2016): "LTE; Evolved Universal Terrestrial Radio Access (E-UTRA); Base station (BS) conformance testing (3GPP TS 36.141 version 11.14.0 Release 11)".

1.2. Applicability

ETSI TS 125 104 (V11.12.0) (01-2016): "Universal Mobile Telecommunications System (UMTS); Base Station (BS) radio transmission and reception (FDD) (3GPP TS 25.104 version 11.12.0 Release 11)".

1.3. Referenced Documents

ETSI TS 125 105 (V11.9.0) (01-2016): "Universal Mobile Telecommunications System (UMTS); Base station (BS) radio transmission and reception (TDD) (3GPP TS 25.105 version 11.9.0 Release 11)".

ETSI TS 125 141 (V11.12.0) (01-2016): "Universal Mobile Telecommunications System (UMTS); Base station (BS) conformance testing (FDD) (3GPP TS 25.141 version 11.12.0 Release 11)".

ETSI TS 136 211 (V11.6.0) (10-2014): "LTE; Evolved Universal Terrestrial Radio Access (E-UTRA); Physical channels and modulation (3GPP TS 36.211 version 11.6.0 Release 11)".

ETSI TR 100 028 (all parts) (V1.4.1): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics".

ETSI TS 136 214 (V11.1.0) (02-2013): "LTE; Evolved Universal Terrestrial Radio Access (E-UTRA); Physical layer; Measurements (3GPP TS 36.214 version 11.1.0 Release 11)".

Recommendation ITU-R SM.329-12 (09-2012): "Unwanted emissions in the spurious domain".

IEC 60721-3-3 (2002): "Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 3: Stationary use at weather-protected locations".

IEC 60721-3-4 (1995): "Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 4: Stationary use at non-weather-protected locations".

1.4.1. Aggregated Channel Bandwidth

The radio frequency bandwidth in which a base station transmits and receives multiple carrier waves that are adjacent and combined.

1.4. Terms and Definitions

NOTE: The unit of measurement for aggregated channel bandwidth is MHz.

1.4.2. Base Station Class

NOTE: The unit of measurement for the aggregated channel bandwidth is MHz.

1.4.2. Base Station class

Wide-area base stations, medium-range base stations, local-area base stations, or indoor base stations as announced by the manufacturer.

1.4.3. Base station RF Bandwidth

The RF bandwidth within which the base station transmits and/or receives one or more carriers in an operational frequency band.

NOTE: In single-carrier operation, the base station RF bandwidth is equal to the channel bandwidth.

1.4.4. Base station RF Bandwidth edge

The frequency of one of the edges of the base station RF bandwidth.

NOTE: The base station RF bandwidth separates the base station RF bandwidth edges.

1.4.5. Carrier

A modulated waveform transmitted over physical channels E-UTRA or UTRA (WCDMA).

1.4.6. Carrier Aggregation

The combination of two or more component carriers to support wider transmission bandwidths.

1.4.7. Carrier Aggregation Band

A set of one or more operational frequency bands in which aggregated carriers share a common set of technical requirements.

NOTE: Tables 3 and 4 specify the carrier aggregation bands for an E-UTRA base station as announced by the manufacturer.

1.4.8. Channel Bandwidth

The RF bandwidth supporting a single RF E-UTRA carrier configured with uplink or downlink transmission bandwidth of a cell.

NOTE: The unit of measurement for channel bandwidth is MHz and it serves as a reference for the RF requirements of the transmitter and receiver.

1.4.9. Channel Edge

The lowest or highest frequency of an E-UTRA carrier.

NOTE: The channel bandwidth separates the channel edges.

1.4.10. Contiguous Carriers

Two or more carriers configured in a spectrum block without a set of RF coexistence requirements for uncoordinated operations within that spectrum block.

1.4.11. Contiguous Spectrum

A spectrum including a contiguous block of spectrum without guard bands between component blocks.

1.4.12. Downlink Operating Band

The portion of the operational frequency band used for downlink (BS transmit).

1.4.13. Downlink Reference Symbol Power

The resource element component power of the downlink reference symbol.

1.4.14. Home Base Station

A base station with characteristics meeting the requirements of a femtocell.

1.4.15. Inter RF Bandwidth Gap

The frequency guard band between two consecutive RF bandwidths of the base station placed in two supported operational frequency bands.

1.4.16. Inter-Band Carrier Aggregation

Carrier aggregation of component carriers in different operational frequency bands.

NOTE: The aggregated carriers in each band may be contiguous or non-contiguous.

1.4.17. Inter-Band Gap

The frequency guard band between two consecutive supported operational frequency bands.

1.4.18. Intra-Band Contiguous Carrier Aggregation

Contiguous carriers aggregated within the same operational frequency band.

1.4.19. Intra-Band Non-Contiguous Carrier Aggregation

Non-contiguous carriers aggregated within the same operational frequency band.

1.4.20. Local Area Base Station

A base station with characteristics meeting the requirements of a picocell with minimum coupling loss from a BS to UE of 45 dB.

1.4.21. Lower Sub-Block Edge

The frequency at the lower edge of a sub-block.

NOTE: It is used as a frequency reference point for both transmitter and receiver requirements.

1.4.22. Maximum Base Station RF Bandwidth

The maximum RF bandwidth supported by a BS in each supported operational frequency band.

1.4.23. Maximum Output Power

The average power level on a carrier of the base station measured at the antenna connector under specified standard conditions.

1.4.24. Maximum Radio Bandwidth

The maximum frequency difference between the upper edge of the highest used carrier and the lower edge of the lowest used carrier.

1.4.25. Maximum Throughput

The maximum throughput achievable for a standardized test channel.

1.4.26. Mean Power

The power measured over the channel bandwidth of a carrier during a measurement period of at least one time slot (1 ms), unless otherwise specified for E-UTRA transmission.

1.4.27. Medium Range Base Station

A base station with characteristics meeting the requirements of a microcell with minimum coupling loss from a BS to UE of 53 dB.

1.4.28. Multi-Band Base Station

A base station with a transmitter and/or receiver capable of processing simultaneously two or more carriers in activated RF components, where at least one carrier is configured differently from the others.

1.4.29. Multi-Band Receiver

A receiver capable of processing simultaneously two or more carriers in activated RF components, where at least one carrier is configured differently from the others.

1.4.30. Multi-Band Transmitter

A transmitter capable of processing simultaneously two or more carriers in activated RF components, where at least one carrier is configured differently from the others.

1.4.31. Multi-Carrier Transmission Configuration

A set of one or more contiguous carriers, which the base station can transmit simultaneously according to the manufacturer's technical specifications.

1.4.32. Non-Contiguous Spectrum

A spectrum including two or more blocks, these blocks being separated by guard bands.

1.4.33. Operational Band

A frequency range (paired or unpaired) defined by a set of technical requirements in which E-UTRA operates.

NOTE: The operating bands of an E-UTRA BS announced by the manufacturer according to Table 1 are numbered with Arabic numerals, while the corresponding operating bands of UTRA are numbered with Roman numerals.

1.4.34. Output power

The average power of a carrier wave from a base station, supplied to a load having an impedance equal to the rated load impedance of the transmitter.

1.4.35. Rated output power

The rated output power of a base station is the level of average power on a carrier wave published by the manufacturer as being available at the antenna connector.

1.4.36. Rated total output power

The level of average power published by the manufacturer as being available at the antenna connector.

1.4.37. Resource block

Physical resources consisting of a number of symbols in the time domain and a number of consecutive subcarriers spanning 180 kHz in the frequency domain.

1.4.38. Sub-block

A spectrum block allocated adjacent for transmission and reception within the same base station.

NOTE: There may be multiple sub-block patterns in a base station RF bandwidth.

1.4.39. Sub-block bandwidth

The bandwidth of a sub-block.

1.4.40. Sub-block gap

The frequency guardband between two consecutive sub-blocks within a base station RF bandwidth, wherein the RF requirements in the guardband are based on coexistence for non-coordinated operations.

1.4.41. Synchronized operation

Operation of TDD in two different systems where uplink and downlink do not occur simultaneously.

1.4.42. Throughput

The number of useful bits received per second on a standard measurement channel under specified standard conditions.

1.4.43. Total RF Bandwidth

The maximum total of the base station RF bandwidths in supported operating bands.

1.4.44. Transmission bandwidth

The instantaneous transmission bandwidth from a UE or BS, measured in resource blocks.

1.4.45. Transmission bandwidth configuration

The highest transmission bandwidth assigned to uplink or downlink within a defined channel bandwidth, measured in resource blocks.

1.4.46. Transmitter OFF period

The time period during which a BS transmitter is not allowed to transmit.

1.4.47. Transmitter ON period

The time period during which a BS transmitter transmits data and/or reference symbols, such as subframe data or DwPTS.

1.4.48. Transmitter transient period

The time period during which a transmitter transitions from the OFF period to the ON period or vice versa.

1.4.49. Unsynchronized operation

Operation of TDD in two different systems where the conditions for synchronized operation are not met.

1.4.50. Uplink operating band

The portion of the operating band designated for uplink (BS receives).

1.4.51. Upper sub-block edge

The frequency at the upper edge of a sub-block.

NOTE: This frequency is used as the reference frequency point for the transmitter and receiver requirements.

1.4.52. Wide area base station

A base station that meets the requirements of a macrocell with a minimum coupling loss from a BS to a UE of 70 dB.

Figure 1 - Channel bandwidth and transmission bandwidth configuration for an E-UTRA carrier.

Figure 2 illustrates the combined channel bandwidth for intra-band contiguous carrier aggregation.

For each carrier, the central subcarrier (corresponding to DC in the basic band) is not transmitted in downlink.

Figure 2 - Combined channel bandwidth for intra-band contiguous carrier aggregation.

The following definitions apply:

- The lower edge of the combined channel bandwidth BWchannel_CA is Fedge_low = FC_low - Foffset;

- The upper edge of the combined channel bandwidth BWChannel_CA is Fedge_high = FC_high + Foffset;

- The combined channel bandwidth BWChannel_CA = Fedge_high - Fedge_low (MHz).

Figure 3 illustrates the sub-block bandwidth for a BS operating in non-contiguous spectrum.

Figure 3 - Sub-block bandwidth for non-contiguous intra-band spectrum.

The following definitions also apply in this standard:

- The lower edge of the sub-block bandwidth Fedge,block,low = FC,block,low - Foffset;

- The upper edge of the sub-block bandwidth Fedge,block,high = FC,block,high + Foffset;

- The combined channel bandwidth BWChannel,block = Fedge,block,high - Fedge,block,low (MHz).

Table 2 defines Foffset, where BWChannel is specified in Table 5.6-1 of ETSI TS 136 141.

Table 2 - Definition of Foffset

Highest or lowest channel bandwidth BWChannel (MHz)Foffset (MHz)5, 10, 15, 20BWChannel/2NOTE 1: The Foffset of each edge of the base station RF bandwidth/sub-block is calculated separately.NOTE 2: The values of BWChannel_CA/BWChannel,block for UE and BS are the same if the bandwidths of the highest and lowest component carriers are identical.

Figure 4 - Maximum radio bandwidth BWmax and total RF bandwidth BWtot of multi-band base station

dBc

BRFBWBăng thông RF trạm gốc cực đại nằm ở cuối của dải tần số được hỗ trợ trong băng tần hoạt độngBWChannelBăng thông kênhBWChannel,blockBăng thông khối thành phần, đơn vị là Mhz. BWChannel,block = Fedge,block,high - Fedge,block,lowBWConfigCấu hình băng thông phát, đơn vị là Mhz, trong đó BWConfig = NRB x 180 kHz cho đường lên và, BWconfig = 15 kHz + NRB x 180 kHz cho đường xuốngBWmaxBăng thông vô tuyến cực đạiBWtotTổng băng thông RFCPICH ÊcCông suất mã hóa kênh hoa tiêu chung (trong kênh lân cận)CRS ÊcCông suất tín hiệu chuẩn nhận được trên phần tử tài nguyênfTần số∆fKhoảng cách giữa tần số biên kênh và điểm -3 dB danh định của bộ lọc đo gần nhất đến tần số sóng mang∆fmaxGiá trị lớn nhất của ∆f sử dụng để xác định yêu cầuFCTần số trung tâm sóng mangFC,block,highTần số trung tâm của sóng mang cao nhất được phát/thu trong một khối thành phầnFC,block, lowTần số trung tâm của sóng mang cao nhất được phát/thu trong một khối thành phầnFC_highTần số trung tâm sóng mang của sóng mang cao nhất, đơn vị là MHzFC_lowTần số trung tâm sóng mang của sóng mang thấp nhất, đơn vị là MHzFedge_lowBiên dưới của băng thông kênh cộng gộp, đơn vị là MHz, Fedge_low = FC_low - FoffsetFedge_highBiên trên của băng thông kênh cộng gộp, đơn vị là MHz, Fedge_high = FC_high - FoffsetFedge,block,lowBiên dưới khối thành phần, trong đó Fedge,block,low = FC,block,low - FoffsetFedge,block,highBiên trên khối thành phần, trong đó Fedge,block,high = FC,block,high - FoffsetFoffsetĐộ lệch tần số từ FC_high đến biên trên băng thông RF trạm gốc hoặc từ FC,block,high đến biên trên khối thành phần, FC_low đến biên dưới băng thông RF trạm gốc hoặc từ FC,block,low đến biên dưới khối thành phầnFfilterTần số trung tâm bộ lọcfinterfererTần số trung tâm của tín hiệu can nhiễurf_offsetKhoảng cách giữa tần số biên kênh và tần số trung tâm bộ lọc đof_offsetmaxGiá trị lớn nhất của f_offset được sử dụng xác định yêu cầuFUL_lowTần số thấp nhất của băng tần hoạt động đường lên (xem Bảng 1)FUL_highTần số cao nhất của băng tần hoạt động đường lên (xem Bảng 1)lohTổng mật độ công suất thu được không bao gồm tín hiệu của trạm gốc trong nhà của chính nóluantGiao diện logíc nội bộ E-Node B giữa chức năng O&M đặc trưng xử lý và các ăng ten RET và khối chức năng điều khiển TMAs của E-Node BNRBCấu hình băng thông phát, đơn vị là các thành phần của các khối tài nguyênpSố cổng ăng ten(Pi)Công suất của tín hiệu tại đầu nối ăng ten i(Ps)Tổng công suất cho tất cả các đầu nối ăng tenP10MHzCông suất đầu ra cực đại tại 10 MHzPEM,NMức phát xạ khai báo cho kênh NPEM,B32,indMức phát xạ khai báo tại băng tần 32, ind = a, b, c, d, ePmax,cCông suất ra sóng mang cực đạiPoutCông suất raPrated,cCông suất ra danh định (trên sóng mang)PREFSENSMức công suất độ nhạy chuẩnTRFBWBăng thông RF trạm gốc cực đại tại đầu của dải tần số được hỗ trợ trong băng tần hoạt độngWgapKhoảng bảo vệ khối thành phần hoặc kích thước khoảng bảo vệ băng thông liên quan

Số khối tài nguyên đường xuống

Số sóng mang con trong một khối tài nguyên, = 12

Bandwidth

ACLRAdjacent Channel Leakage RatioTỷ số công suất rò kênh lân cậnACSAdjacent Channel SelectivityĐộ chọn lọc kênh lân cậnATTAttenuatorBộ suy giảmAWGNAdditive White Gaussian NoiseNhiễu Gauss trắng cộng tínhBBottom RF channelKênh RF cuốiBRFBWBottom Radio Frequency channel Bandwidth BSBăng thông kênh tần số vô tuyến cuối trạm gốcBSBase StationTrạm gốcBTSBase Transceiver stationTrạm thu phát gốcBWBandwidthBăng thôngCContiguousLiền kềCACarrier AggregationCộng gộp sóng mangCACLRCumulative ACLRACLR lũy kếCSGClosed Subscriber GroupNhóm thuê bao đóngCWContinuous WaveSóng liên tụcDCDirect CurrentNguồn một chiềuDLDown LinkĐường xuốngDTTDigital Terrestrial TelevisionTruyền hình kỹ thuật số mặt đấtDwPTSDownlink part of the special subframePhần đường xuống của khung thành phần đặc biệtEARFCNE-UTRA Absolute Radio Frequency Channel NumberSố kênh tần số vô tuyến tuyệt đối E-UTRAERMEMC and Radio spectrum MattersTương thích điện từ trường và phổ tần sốE-TME-UTRA Test ModelMô hình đo kiểm E-UTRAEUTEquipment Under TestThiết bị được đo kiểmE-UTRAEvolved UMTS Terrestrial Radio AccessTruy nhập vô tuyến mặt đất UMTS tiến hóaFDDFrequency Division DuplexGhép song công phân chia theo tần sốFRCFixed Reference ChannelKênh chuẩn cố địnhGSMGeneral System for Mobile communicationsHệ thống thông tin di động toàn cầuIMTInternational Mobile TelecommunicationsMạng thông tin di động toàn cầuMMiddle RF channelKênh RF giữaMBTMulti-Band TestingĐo kiểm đa băng tầnMSMobile StationTrạm di độngMSGMobile Standards GroupNhóm các tiêu chuẩn di độngMSRMulti-Standard RadioVô tuyến đa tiêu chuẩnMUEMacro UEThiết bị người dùng macroRATRadio Access TechnologyCông nghệ truy nhập vô tuyếnRBResource BlockKhối tài nguyênRFRadio FrequencyTần số vô tuyếnRFBWRadio Frequency BandwidthBăng thông tần số vô tuyếnRMSRoot Mean SquareGiá trị hiệu dụngRRCRoot Raised CosineCosin nângRXReceiveThuSBTSingle Band TestingĐo kiểm băng tần đơnTTop RF channelKênh RF đầuTDDTime Division DuplexGhép song công phân chia theo thời gianTFESTask Force for European Standards for IMTNhóm các tiêu chuẩn Châu Âu cho IMTTRFBWTop Radio Frequency channel BandwidthBăng thông kênh tần số vô tuyến đầuTXTransmitPhátUEUser EquipmentThiết bị người dùngULUpLinkĐường lênUMTSUniversal Mobile Telecommunications SystemHệ thống viễn thông di động toàn cầuUTRAUMTS Terrestrial Radio AccessTruy nhập vô tuyến mặt đất UMTS

Chapter 2. TECHNICAL PROVISIONS

2.2.1. General Requirements

Các yêu cầu kỹ thuật của quy chuẩn này áp dụng trong điều kiện môi trường hoạt động của thiết bị do nhà cung cấp khai báo. Thiết bị phải hoàn toàn tuân thủ mọi yêu cầu kỹ thuật của quy chuẩn này khi hoạt động trong các giới hạn biên của điều kiện môi trường hoạt động được khai báo.

Phụ lục B hướng dẫn nhà cung cấp cách khai báo điều kiện môi trường.

2.2.2. Unwanted Emissions within the Operating Band

2.2.3. Adjacent Channel Leakage Ratio (ACLR)

Nhà sản xuất thiết bị phải công bố:

- Các băng tần hoạt động của trạm gốc;

- Các băng tần hoạt động của trạm gốc hỗ trợ cộng gộp sóng;

- Các cấu hình RF được hỗ trợ theo quy định trong điều 4.6.8 của ETSI TS 136 141.

For base stations supporting multiple frequency bands, the measurements prescribed in Article 3 must be conducted for each individual frequency band.

For base stations configured to receive multiple carrier waves, all throughput requirements must apply to each received carrier wave. As for the ACS characteristics, blocking, and modulation penetration, the signal-to-noise ratios must be measured relative to the upper edge of the RF bandwidth of the base station.

For base stations capable of operating across multiple frequency bands, the requirements set forth in this standard apply to each operational frequency band unless otherwise specified. In certain cases, specific additional or removed requirements may be stipulated for such base stations.

For base stations capable of operating across multiple frequency bands that are a combination of different multi-band or single-band devices mapped to one or more antenna ports in various ways, if the frequency bands are transmitted on separate antennas then:

- Single-band ACLR measurement, unwanted emissions within the operational frequency band, spurious transmitter emissions, transmitter modulation penetration, and spurious receiver emissions shall be applied to each antenna port connection;

- If the base station configuration operates in a single frequency band, the single-band requirements apply to the antenna port configured for single-band operation and apply to both single-band and multi-band capable base stations. The single-band requirements are independently tested at the antenna port configured for single-band operation while all other antenna ports remain terminated.

For multi-band capable base stations supporting frequency bands for Time Division Duplexing (TDD), the RF requirements in this standard assume synchronous operation, where the uplink and downlink do not occur simultaneously across supported operational frequency bands.

Technical requirements applicable to base station configurations are specified in Appendix A.

The E-UTRA base station operates in aggregated carrier frequency bands as defined in Tables 3 through Table 6.

Table 3 - Aggregated Carrier Frequency Bands Within Band

Frequency BandCABand Operating FrequencyCA_11CA_33CA_77CA_3838CA_4040

Table 4 - Aggregated Carrier Frequency Bands Across Bands (Two Bands)

Frequency BandCACarrier Frequencies OperatingCA_1-313CA_1-717CA_3-818CA_3-737CA_3-838CA_7-878CA_8-40840

Table 5 - Aggregated Carrier Frequency Bands Across Bands (Three Bands)

Frequency BandCACarrier Frequencies OperatingCA_1-3-8138

Table 6 - Non-adjacent Aggregated Carrier Frequency Bands Within Band (Two Component Blocks)

Frequency BandCACarrier Frequencies OperatingCA_3-33CA_7-77

2.2.4. Spurious Transmitter Emissions

2.2.2.1. Definition

Unwanted emissions include out-of-band emissions and spurious emissions. Out-of-band emissions are unwanted emissions (excluding spurious emissions) occurring immediately outside the channel bandwidth during modulation and due to non-linear effects in the transmitter. The limits of out-of-band emissions from the base station transmitter are determined based on unwanted emissions within the operational frequency band and adjacent channel leakage ratio (ACLR).

Limits for unwanted spurious emissions within the operational frequency band are defined from 10 MHz below the lowest frequency of each supported downlink operational frequency band to 10 MHz above the highest frequency of each supported downlink operational frequency band (see Table 1).

These requirements apply to all types of transmitters (single-carrier or multi-carrier) and all selected transmission modes consistent with the manufacturer's technical specifications. Additionally, for base stations operating across multiple frequency bands, these requirements apply within the guard band RF bandwidth.

For base stations supporting multiple carriers, the unwanted emission requirements apply to channel bandwidths greater than or equal to 5 MHz.

For multi-carrier E-UTRA base stations configured for adjacent and non-adjacent intra-band carrier aggregation, the definitions above apply to the lower edge of the transmitting carrier at the lowest carrier frequency and the upper edge of the transmitting carrier at the highest carrier frequency within the defined operational frequency band.

For multi-band capable base stations where multiple frequency bands are mapped to separate antenna ports, single-band requirements apply and cumulative limit estimation within the guard band RF bandwidth is not applied.

2.2.2.2. Limits

For wide-area base stations, this requirement applies outside the RF bandwidth of the base station. Additionally, this requirement also applies within the guard band of any component block for wide-area base stations operating in non-contiguous spectrum and within the guard band RF bandwidth of any contiguous frequency band for wide-area base stations operating across multiple frequency bands.

For base stations with medium coverage areas, this requirement applies outside the RF bandwidth of the base station. Additionally, this requirement applies within the guard band of any component block for base stations with medium coverage areas operating in non-contiguous spectrum and within the guard band RF bandwidth of any contiguous frequency band for base stations with medium coverage areas operating across multiple frequency bands.

For local base stations, this requirement applies outside the RF bandwidth of the base station. Additionally, this requirement applies within the guard band of any component block for local base stations operating in non-contiguous spectrum and within the guard band RF bandwidth of any contiguous frequency band for local base stations operating across multiple frequency bands.

Outside the RF bandwidth of the base station, emissions do not exceed the maximum levels specified in Tables 7, 8, 11, and 12, wherein:

- ∆f is the distance between the channel edge frequency and the -3 dB reference point of the closest measurement filter near the carrier frequency;

- f_offset is the distance between the channel edge frequency and the center frequency of the measurement filter;

- f_offsetmax is the deviation from the 10 MHz outside the downlink operational frequency band;

- ∆fmax equals f_offsetmax minus half the bandwidth of the measurement filter.

For base stations operating across multiple frequency bands, within any guard band RF bandwidth with Wgap < 20 MHz, emissions do not exceed the cumulative total of the limits specified at the edges of the base station RF bandwidth on each side of the guard band RF bandwidth. The limits for the base station RF bandwidth edges are specified in Tables 7, 8, 11, and 12, wherein:

- ∆f is the distance between the base station RF bandwidth edge frequency and the -3 dB reference point of the closest measurement filter near the base station RF bandwidth edge.

- f_offset is the distance between the edge frequency of the RF bandwidth of the base station and the center frequency of the measurement filter;

- f_offsetmax equals the inter-band RF protection band width minus half the bandwidth of the measurement filter;

- ∆fmax equals f_offsetmax minus half the bandwidth of the measurement filter.

For wide-area BSs capable of multi-carrier operation, where multiple bands are mapped onto the same antenna port, the limits on unwanted emissions in the operating band also apply within any supported downlink band inside any transmitted carrier, in cases where there are (any) transmitted carriers in other supported operating bands. In this case, the non-cumulative limits apply within the inter-band protection band between a supported downlink band and (any) transmitted carriers and another supported downlink band outside any transmitted carrier, and:

- In the case where the inter-band protection band between a supported downlink band and (any) transmitted carriers and another supported downlink band outside any transmitted carrier is less than 20 MHz, f_offsetmax is the deviation from the 10 MHz frequency outside the outermost edges of the supported downlink bands and the limits on unwanted emissions in the operating band, where there are transmitted carriers, specified in the tables of this Article, apply to both downlink bands.

- In the case, the limits on unwanted emissions in the operating band of the band, where there are transmitted carriers, specified in the tables of this Article for the widest frequency deviation (∆fmax), apply from 10 MHz below the lowest frequency up to 10 MHz above the highest frequency of the supported downlink band outside any transmitted carrier.

Additionally, within any component block protection band with a wide-area BS operating in non-contiguous spectrum, the measurement results do not exceed the cumulative total of the limits prescribed for adjacent component blocks on each side of the component block protection band. The limit for each component block is specified in Tables 7, 8, 11, and 12, in this case:

- ∆f is the distance between the edge frequency of the component block and the -3 dB nominal point of the measurement filter closest to the edge of the component block;

- f_offset is the distance between the edge frequency of the component block and the center frequency of the measurement filter;

- f_offsetmax equals the component block protection band bandwidth minus half the bandwidth of the measurement filter;

- ∆fmax equals f_offsetmax minus half the bandwidth of the measurement filter.

2.2.2.2.1. Limits for Wide-Area BSs (Bands 1, 3, and 8)

For wide-area E-UTRA BSs operating in Bands 1, 3, and 8, emissions do not exceed the maximum levels specified in Table 7.

Table 7 - Limits on unwanted emissions in the operating band of wide-area BSs for channel bandwidths of 5, 10, 15, and 20 MHz (Bands 1, 3, and 8)

Frequency deviation of the -3 dB point of the measurement filter, ∆fFrequency deviation of the center frequency of the measurement filter, f_offsetLimit(Notes 1, 2, and 3)Measurement bandwidth0 MHz ≤ ∆f < 0.2 MHz0.165 MHz ≤ f_offset < 0.215 MHz-12.5 dBm30 kHz1.015 MHz ≤ f_offset < 1.5 MHz-24.5 dBm30 kHz1 MHz ≤ ∆f ≤ minimum (10 MHz, ∆fmax)1.5 MHz ≤ f_offset < minimum (10.5 MHz, ∆f_offsetmax)-11.5 dBm1 MHz10 MHz ≤ ∆f ≤ ∆fmax10.5 MHz ≤ f_offset < f_offsetmax-15 dBm1 MHzNOTE 1: Requirements do not apply when ∆fmax < 10 MHz.NOTE 2: For BSs supporting non-contiguous spectrum operation in any band, the limits within the component block protection band are calculated as the cumulative total of the portions from adjacent component blocks on each side of the component block protection band, where the portion from the farthest component block is proportioned according to the measurement bandwidth of the nearest component block. Except in the case where ∆f ≥ 10 MHz from both adjacent component blocks on each side of the component block protection band, where the limit within the component block protection band is -13 dBm/100 kHz.NOTE 3: For BSs supporting multi-band operation with an RF inter-band protection band < 20 MHz, the limit within the RF inter-band protection band is calculated as the cumulative total of the portions from adjacent component blocks or the RF bandwidth of the base station on each side of the RF inter-band protection band, where the elements of the farthest component block or the RF bandwidth of the base station are proportioned according to the measurement bandwidth of the nearest component block or the RF bandwidth of the base station.

0.2 MHz ≤ ∆f < 1 MHz 0.215 MHz ≤ f_offset < 1.015 MHz

30 kHz

2.2.2.2.2. Limits for Wide-Area BSs (Bands 7, 38, and 40)

For wide-area E-UTRA BSs operating in Bands 7, 38, and 40, emissions do not exceed the maximum levels specified in Table 8.

Table 8 - Limits on unwanted emissions in the operating band of wide-area BSs for channel bandwidths of 5, 10, 15, and 20 MHz (Bands 7, 38, and 40)

Frequency deviation at the -3 dB point of the measurement filter, ∆fFrequency deviation from the center frequency of the measurement filter, f_offsetLimitations (notes 1, 2, and 3)Measurement bandwidth5 MHz ≤ ∆f < minimum (10 MHz, ∆fmax)5,05 MHz ≤ f_offset < minimum (10,05 MHz, f_offsetmax)-12,5 dBm100 kHz10 MHz ≤ ∆fmax10,5 MHz ≤ f_offset < f_offsetmax-15 dBm1 MHzNOTE 1: The requirement does not apply when ∆fmax < 10 MHz.NOTE 2: For BS supporting non-contiguous spectrum operation in any band, the limits within the component block protection bands are calculated as the cumulative sum of the elements of adjacent component blocks on each side of the protection band, where the farthest component block elements are scaled according to the measurement bandwidth of the nearest component block. Except if ∆f ≥ 10 MHz from both adjacent component blocks on each side of the protection band, in which case the limit within the component block protection bands is -13 dBm/100 kHz.NOTE 3: For BS supporting multi-band operation with inter-RF bandwidth protection band < 20 MHz, the limit within the inter-RF bandwidth protection band is calculated as the cumulative sum of the elements of adjacent component blocks or the RF bandwidth of the base station on each side of the inter-RF bandwidth protection band, where the farthest component block elements or the RF bandwidth of the base station are scaled according to the measurement bandwidth of the nearest component block or the RF bandwidth of the base station.

0 MHz ≤ ∆f < 5 MHz 0,05 MHz ≤ f_offset < 5,05 MHz

-54 dBm

2.2.2.2.3. Limits for Internal Base Stations

For internal base stations, emissions do not exceed the maximum levels specified in Table 9.

Table 9 - Unwanted emission limits in the operating band of internal base stations for channel bandwidths of 5, 10, 15, and 20 MHz

Frequency deviation at the 3 dB point of the measurement filter, ∆fFrequency deviation from the center frequency of the measurement filter, f_offsetLimitMeasurement bandwidth5 MHz ≤ ∆f < minimum (10 MHz, ∆fmax)5,05 MHz ≤ f_offset < minimum (10,05 MHz, f_offsetmax)-35,5 dBm100 kHz10 MHz ≤ ∆f ≤ ∆fmax10,5 MHz ≤ f_offset < f_offsetmax-37 dBm (see note)100 MHzNOTE 1: The requirement does not apply when ∆fmax < 10 MHz.

0 MHz ≤ ∆f < 5 MHz 0,05 MHz ≤ f_offset < 5,05 MHz

-54 dBm

2.2.2.2.4. Limits for Indoor Base Stations

For indoor base stations, emissions do not exceed the maximum levels specified in Table 10.

Table 10 - Unwanted emission limits in the operating band of indoor base stations for channel bandwidths of 5, 10, 15, and 20 MHz

Frequency deviation at the -3 dB point of the measurement filter, ∆fFrequency deviation from the center frequency of the measurement filter, f_offsetLimitMeasurement bandwidth5 MHz ≤ ∆f < minimum (10 MHz, ∆fmax)5,05 MHz ≤ f_offset < minimum (10,05 MHz, f_offsetmax)-40,5 dBm100 kHz10 MHz ≤ ∆f ≤ ∆fmax10,5 MHz ≤ f_offset < f_offsetmaxP-52 dB, 2dBm ≤ P ≤ 20 dBm-50 dBm, P < 2 dBm (see notes 1 and 2)1 MHzNOTE 1: For indoor base stations, parameter P is the maximum combined power of all antenna ports of the indoor base station.NOTE 2: The requirement does not apply when ∆fmax < 10 MHz.

0 MHz ≤ ∆f < 5 MHz 0,05 MHz ≤ f_offset < 5,05 MHz

-54 dBm

2.2.2.2.5. Limits for Base Stations with Medium Coverage Areas

For base stations with medium coverage areas E-UTRA, emissions do not exceed the maximum levels specified in Tables 11 and 12.

Table 11 - Unwanted emission limits in the operating band of base stations with medium coverage areas for channel bandwidths of 5, 10, 15, and 20 MHz, 31 < Pmax,c ≤ 38 dBm

Frequency deviation at the -3 dB point of the measurement filter, ∆fFrequency deviation from the center frequency of the measurement filter, f_offsetLimit (notes 1 and 3)Measurement bandwidth5 MHz ≤ ∆f < minimum (10 MHz, ∆fmax)5,05 MHz ≤ f_offset < minimum (10,05 MHz, f_offsetmax)Pmax,c - 58,5 dBm100 kHz10 MHz ≤ ∆f ≤ ∆fmax10,05 MHz ≤ f_offset < f_offsetmaxminimum (Pmax,c - 60 dB, -25 dBm) (see note 2)100 kHzNOTE 1: For base stations supporting non-contiguous spectrum operation in any band, the limits within the component block protection bands are calculated as the cumulative sum of the elements of adjacent component blocks on each side of the protection band. Except if ∆f ≥ 10 MHz from both adjacent component blocks on each side of the protection band, in which case the limit within the component block protection bands is minimum (Pmax,c - 60 dB, -25 dBm)/100 kHz.NOTE 2: The requirement does not apply when ∆Fmax < 10 MHz.NOTE 3: For base stations supporting multi-band operation with inter-RF bandwidth protection band < 20 MHz, the limit within the inter-RF bandwidth protection band is calculated as the cumulative sum of the elements of adjacent component blocks or the RF bandwidth of the base station on each side of the inter-RF bandwidth protection band.

0 MHz ≤ ∆f < 5 MHz 0,05 MHz < f_offset < 5,05 MHz

-54 dBm

Table 12 - Unwanted emission limits in the operating band of base stations with medium coverage areas for channel bandwidths of 5, 10, 15, and 20 MHz, Pmax,c ≤ 31 dBm

Frequency deviation at the -3 dB point of the measurement filter, ∆fFrequency deviation from the center frequency of the measurement filter, f_offsetLimit (notes 1 and 3)Measurement bandwidth5 MHz ≤ ∆f < minimum (10 MHz, ∆fmax)5,05 MHz ≤ f_offset < minimum (10,05 MHz, f_offsetmax)-27,5 dBm100 kHz10 MHz ≤ ∆f ≤ ∆fmax10,05 MHz ≤ f_offset < f_offsetmax-29 dBm (see note 2)100 kHzNOTE 1: For base stations supporting non-contiguous spectrum operation in any band, the limits within the component block protection bands are calculated as the cumulative sum of the elements of adjacent component blocks on each side of the protection band. Except if ∆f ≥ 10 MHz from both adjacent component blocks on each side of the protection band, in which case the limit within the component block protection bands is -29 dBm/100 kHz.NOTE 2: The requirement does not apply when ∆fmax < 10 MHz.NOTE 3: For base stations supporting multi-band operation with inter-RF bandwidth protection band < 20 MHz, the limit within the inter-RF bandwidth protection band is calculated as the cumulative sum of the elements of adjacent component blocks or the RF bandwidth of the base station on each side of the inter-RF bandwidth protection band.

0 MHz ≤ ∆f < 3 MHz 0,05 MHz ≤ f_offset < 5,05 MHz

-54 dBm

2.2.2.3. Measurement Methods

Use the measurements specified in Article 3.3.1

2.2.5. Maximum Output Power of the Base Station

2.2.3.1. Definition

Unwanted emissions include out-of-band emissions and spurious emissions. Out-of-band emissions are emissions lying just outside the bandwidth of the channel, generated during modulation and due to the influence of nonlinearity in the transmitter. The limits of the out-of-band emissions of the base station (BS) transmitter are determined according to the unwanted emissions within the operating frequency band and the adjacent channel leakage ratio (ACLR).

The adjacent channel leakage ratio (ACLR) is the ratio between the average power of the root-raised cosine (RRC) filtered carrier centered on the assigned channel frequency and the average power of the RRC filtered carrier centered on the adjacent channel frequency.

This requirement applies outside the base station's radio frequency (RF) bandwidth or the maximum radio bandwidth for any type of transmitter (single-carrier or multi-carrier) and for any selected transmission mode that complies with the manufacturer's technical specifications. The signal-to-interference deviation is determined relative to the base station's RF bandwidth edges.

For a BS operating in non-contiguous spectrum, the ACLR applies to the first adjacent channel within the guard band of any component block having a guard band width Wgap ≥ 15 MHz. The ACLR requirement applies to the second adjacent channel within the guard band of any component block having a guard band width Wgap ≥ 20 MHz. The CACLR requirements specified in Article 2.2.3.2.2 apply within the guard bands for the specified frequency ranges in Table 13 for contiguous spectrum and Table 14 for non-contiguous spectrum.

For BS operating across multiple bands, these bands are mapped to the same antenna port, the ACLR applies to the first adjacent channel within the inter-band RF guard band with a guard band width Wgap ≥ 15 MHz. The ACLR requirement for the second adjacent channel applies within any inter-band RF guard band with any guard band width Wgap ≥ 20 MHz. The CACLR requirements in Article 2.2.3.2.2 apply within the inter-band RF guard bands for the specified frequency ranges in Table 13 for contiguous spectrum and Table 14 for non-contiguous spectrum.

These requirements apply throughout the transmitter's ON cycle.

2.2.3.2. Limits

2.2.3.2.1. ACLR Limits

ACLR with a square pulse filter of bandwidth equal to the configured transmission bandwidth (BWConfig) centered on the calculated channel frequency and a filter centered on the adjacent channel frequency as specified in Tables 13 and 14.

For wide-area BS, the ACLR limit is the limit specified in Tables 13 and 14 or the absolute limit of -15 dBm/MHz, whichever is less stringent.

For BS with medium coverage area, the ACLR limit is the limit specified in Tables 13 and 14 or the absolute limit of -25 dBm/MHz, whichever is less stringent.

For indoor BS, the ACLR limit is the limit specified in Tables 13 and 14 or the absolute limit of -50 dBm/MHz, whichever is less stringent.

For operation in contiguous spectrum, the ACLR must be greater than the value specified in Table 13.

Table 13 - ACLR of the base station in contiguous spectrum

Channel bandwidth of the lowest/highest allocated carrier E-UTRA BWChannel (MHz)Frequency offset of the center frequency of the adjacent channel BS below the lowest center frequency or above the highest center frequency of the allocated carrier Carrier of the adjacent channel assumed (Reference)Adjacent channel filter frequency and corresponding filter bandwidth ACLR Limit5, 10, 15, 20BWChannelE-UTRA same BWSquare (BWconfig)44.2 dB2 x BWChannelE-UTRA same BWSquare (BWconfig)44.2 dBBWChannel/2 + 2.5 MHzUTRA 3.84 McpsRRC (3.84 Mcps)44.2 dBBWChannel/2 + 7.5 MHzUTRA 3.84 McpsRRC (3.84 Mcps)44.2 dBNOTES 1: BWChannel and BWconfig are the transmission bandwidth configuration and the channel bandwidth of the lowest/highest allocated carrier E-UTRA on the calculated channel frequency. NOTE 2: The RRC filter corresponds to the pulse-shaped filter defined in ETSI 125 104, with the chip rate as specified in this table.

For operation in non-contiguous spectrum, the ACLR must be greater than the value specified in Table 14.

Table 14 - ACLR of the base station in non-contiguous spectrum with synchronous operation

Channel bandwidth of the lowest/highest allocated carrier E-UTRA BWChannel (MHz)Frequency offset of the center frequency of the adjacent channel BS below the lowest center frequency or above the highest center frequency of the allocated carrier Carrier of the adjacent channel assumed (Reference)Adjacent channel filter frequency and corresponding filter bandwidth ACLR Limit5, 10, 15, 20BWChannelE-UTRA same BWSquare (BWconfig)44.2 dB2 x BWChannelE-UTRA same BWSquare (BWconfig)44.2 dBBWChannel/2 + 0.8 MHzUTRA 1.28 McpsRRC (1.28 Mcps)44.2 dBBWChannel/2 + 2.4 MHzUTRA 1.28 McpsRRC (1.28 Mcps)44.2 dBBWChannel/2 + 2.5 MHzUTRA 3.84 McpsRRC (3.84 Mcps)44.2 dBBWChannel/2 + 7.5 MHzUTRA 3.84 McpsRRC (3.84 Mcps)44.2 dBBWChannel/2 + 5 MHzUTRA 7.68 McpsRRC (7.68 Mcps)44.2 dBBWChannel/2 + 15 MHzUTRA 7.68 McpsRRC (7.68 Mcps)44.2 dBNOTES 1: BWChannel and BWconfig are the transmission bandwidth configuration and the channel bandwidth of the lowest/highest allocated carrier E-UTRA on the calculated channel frequency. NOTE 2: The RRC filter corresponds to the pulse-shaped filter defined in ETSI 125 105, with the chip rate as specified in this table.

Table 15 - ACLR of the base station in non-contiguous spectrum

Guard band width (Wgap) when the limit appliesFrequency offset of the center frequency of the adjacent channel BS below or above the edge of the component block (within the guard band) Carrier of the adjacent channel assumed (Reference)Adjacent channel filter frequency and corresponding filter bandwidth ACLR LimitWgap ≥ 15 MHz2.5 MHzUTRA 3.84 McpsRRC (3.84 Mcps)44.2 dBWgap ≥ 20 MHz7.5 MHzUTRA 3.84 McpsRRC (3.84 Mcps)44.2 dBNOTE: The RRC filter corresponds to the pulse-shaped filter defined in ETSI 125 104, with the chip rate as specified in this table.

For operation in non-contiguous spectrum, the ACLR must be greater than the value specified in Table 16.

Table 16 - ACLR of the base station in non-contiguous spectrum

The size of the component block protection gap (Wgap) when applying the frequency deviation limit of the adjacent channel BS below or above the edge of the component block (within the protection band)Filter bandwidth of the adjacent channel and corresponding filter bandwidthFrequency deviation limit ACLRWgap ≥ 15 MHz2,5 MHzRectangular (BWconfig)44,2 dBWgap ≥ 20 MHz7,5 MHzRectangular (BWconfig)44,2 dB

2.2.3.2.2. Cumulative ACLR limits within non-contiguous spectrum bands

Requirements apply to the size of the component block protection gap or the inter-RF band protection gap listed in Table 17:

- Within a component block protection gap in the operating band for BS operating in non-contiguous spectrum bands;

- Within an inter-RF band protection gap for BS operating across multiple bands, where these bands are mapped onto the same antenna port.

The cumulative adjacent channel leakage ratio (ACLR) power ratio within a component block protection gap or an inter-RF band protection gap is the ratio of:

a) The total average filtered carrier power on the assigned channel frequencies for both adjacent carriers to each side of the component block protection gap or inter-RF band protection gap; and

b) The average filtered carrier power on an adjacent channel frequency to one of the edges of the component block or inter-RF band at the base station.

The assumed filters for the adjacent channel frequencies are specified in Table 17 for paired spectrum and Table 18 for unpaired spectrum. The filters on the assigned channels are specified in Table 19.

For wide-area BS, the CACLR limit is the limit specified in Table 17 for paired spectrum and Table 18 for unpaired spectrum or the absolute limit of -15 dBm/MHz, whichever is less stringent.

For medium-area BS, the CACLR limit is the limit specified in Table 17 for paired spectrum and Table 18 for unpaired spectrum or the absolute limit of -32 dBm/MHz, whichever is less stringent.

For local-area BS, the CACLR limit is the limit specified in Table 17 for paired spectrum and Table 18 for unpaired spectrum or the absolute limit of -50 dBm/MHz, whichever is less stringent.

For operation in non-contiguous spectrum or multiple carriers, the CACRL for the E-UTRA carriers on each side of the component block protection gap or inter-RF band protection gap must be greater than the value specified in Table 17 for paired spectrum and Table 18 for unpaired spectrum.

Table 17 - CACLR of the base station in non-contiguous paired spectrum

The size of the component block protection gap or inter-RF band protection gap (Wgap) when applying the frequency deviation limit of the adjacent channel BS below or above the edge of the component block or inter-RF band (within the protection band)Assumed adjacent channel carrier (Reference)Filter bandwidth of the adjacent channel and corresponding filter bandwidthFrequency deviation limit ACLR5 MHz ≤ Wgap < 15 MHz2,5 MHzUTRA 3,84 McpsRRC (3,84 Mcps)44,2 dB10 MHz ≤ Wgap < 20 MHz7,5 MHzUTRA 3,84 McpsRRC (3,84 Mcps)44,2 dBNOTES: The RRC filter corresponds to the pulse-shaped filter defined in ETSI 125 104, with the chip rate as specified in this table.

Table 18 - CACLR of the base station in non-contiguous unpaired spectrum

The size of the component block protection gap or inter-RF band protection gap (Wgap) when applying the frequency deviation limit of the adjacent channel BS below or above the edge of the component block or inter-RF band (within the protection band)Filter bandwidth of the adjacent channel and corresponding filter bandwidthFrequency deviation limit ACLR5 MHz ≤ Wgap < 15 MHz2,5 MHzRectangular (BWconfig)44,2 dB10 MHz ≤ Wgap < 20 MHz7,5 MHzRectangular (BWconfig)44,2 dB

Table 19 - Filter parameters for the assigned channel

RAT of the adjacent network carrier to the component block protection gap or inter-RF bandBPF bandwidth of the assigned channel and corresponding filter bandwidthE-UTRAE-UTRA same BWNOTES: The RRC filter corresponds to the pulse-shaped filter defined in ETSI 125 104, with the chip rate as specified in this table.

2.2.3.3. Measurement methods

Use the measurements described in Article 3.3.2.

2.2.6. Transmitter Modulation Characteristics

2.2.4.1. Definition

Unwanted emissions include out-of-band emissions and spurious emissions. Spurious emissions are emissions generated due to unwanted effects of the transmitter such as harmonic emissions, parasitic emissions, modulation products, and frequency conversion products, excluding out-of-band emissions. This value is measured at the base station's antenna port.

Spurious emission limits of the transmitter from 9 kHz to 12.75 GHz, excluding the frequency range from 10 MHz below the lowest downlink operating band frequency to 10 MHz above the highest downlink operating band frequency (see Table 1). Exclusions must be applied for each supported operating band with BS capable of multi-band operation, where multiple bands are mapped onto the same antenna port. Single-band requirements must be applied and multi-band exclusion and protection must not be applied for BS capable of multi-band operation, where multiple bands are mapped into separate antenna ports. Upper frequency limits above 12.75 GHz for operating bands.

For a BS supporting multiple carriers, unwanted emissions apply to channel bandwidths of carriers outside the main carrier larger than or equal to 5 MHz.

Requirements must be applied to all types of transmitters (single-carrier or multi-carrier). These requirements apply to all selected transmission modes compatible with the manufacturer's technical specifications. All requirements are measured as average power (RMS), unless otherwise specified.

2.2.4.2. Limits

2.2.4.2.1. Spurious emissions

The power of any spurious emission must not exceed the limits in Table 20.

Table 20 - Mandatory spurious emission limits of BS

Frequency BandMaximum ValueBandwidth MeasurementNotes9 kHz to 150 kHz-36 dBm1 kHzNote 1150 kHz to 30 MHz-36 dBm10 kHzNote 130 MHz to 1 GHz-36 dBm100 kHzNote 11 GHz to 12.75 GHz-30 dBm1 MHzNote 2NOTE 1: The bandwidth as defined in Recommendation ITU-R SM.329-12, Article 4.1.NOTE 2: The bandwidth as defined in Recommendation ITU-R SM.329-12, Article 4.1. Frequencies higher than those listed are as specified in Recommendation ITU-R SM.329-12, Article 2.5 Table 1-1.

2.2.4.2.2. Operation with Other Systems

This requirement must be applied to protect the UE/MS and the receivers of other systems' BS/BTS.

The power of any spurious emission must not exceed the limits set out in Table 21. The conditions and exclusions noted in the Notes to Table 21 must be applied for each frequency band for multi-band capable BSs. For multi-band capable BSs, the conditions and exclusions noted in the Notes to Table 21 must be applied for the frequency bands supported at separate antenna ports.

Table 21 - Spurious Emission Limits for Protection of Other Systems

Protected SystemFrequency BandMaximum ValueBandwidth MeasurementNotesGSM 900925 MHz to 960 MHz-57 dBm100 kHzThis requirement does not apply to E-UTRA BS operating in the 880 MHz to 915 MHz band.-61 dBm100 kHzFor the 880 MHz to 915 MHz band, this requirement does not apply to E-UTRA BS operating in band 8 as 2.2.4.2.3 specifies these requirements.GSM 18001805 MHz to 1880 MHz-47 dBm100 kHzThis requirement does not apply to E-UTRA BS operating in band 31710 MHz to 1785 MHz-61 dBm100 kHzThis requirement does not apply to E-UTRA BS operating in band 3 as 2.2.4.2.3 specifies these requirements.W-CDMA FDD 2100, E-UTRA band 12110 MHz to 2170 MHz-52 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 11920 MHz to 1980 MHz-49 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 1 as 2.2.4.2.3 specifies these requirements.W-CDMA FDD 1800, E-UTRA band 31805 MHz to 1880 MHz-52 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 31710 MHz to 1785 MHz-49 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 3 as 2.2.4.2.3 specifies these requirements.W-CDMA FDD 850869 MHz to 880 MHz-52 dBm1 MHz824 MHz to 835 MHz-49 dBm1 MHzE-UTRA band 72620 MHz to 2690 MHz-52 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 72500 MHz to 2570 MHz-49 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 7 as 2.2.4.2.3 specifies these requirements.W-CDMA FDD 900, E-UTRA band 8925 MHz to 960 MHz-52 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 8880 MHz to 915 MHz-49 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 8 as 2.2.4.2.3 specifies these requirements.E-UTRA band 382570 MHz to 2620 MHz-52 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 38. See Note 2 for operation in band 7.E-UTRA band 402300 MHz to 2400 MHz-52 dBm1 MHzThis requirement does not apply to E-UTRA BS operating in band 40.NOTE 1: Where there are two provisions for overlapping or adjacent frequency ranges, both limits shall be applied simultaneously.NOTE 2: Requirements for bands in 2.2.4.1 apply. Simultaneous requirements in the table do not apply to the 10 MHz immediately outside the downlink operating band (see Table 1) or the downlink operating band adjacent to the protected system's band in this table.

2.2.4.2.3. Protection of the BS Receiver of the Same BS or Another BS

This requirement must be applied to prevent the BS receivers from being desensitized by emissions from a BS transmitter.

The power of any spurious emission must not exceed the limit in Table 22, depending on the eNodeB class declared.

Table 22 - Spurious Emission Limits for Protection of the BS Receiver

eNodeB ClassFrequency BandMaximum ValueBandwidth MeasurementNotesWide Area BSFUL_low to FUL_high-96 dBm100 kHzMedium Coverage BSFUL_low to FUL_high-91 dBm100 kHzLocal BSFUL_low to FUL_high-88 dBm100 kHzIn-Building BSFUL_low to FUL_high-88 dBm100 kHzNOTE: FUL_low and FUL_high are the lowest and highest frequencies of the uplink operating band for the E-UTRA BS respectively.

2.2.4.2.4. Operation with In-Building BS in Different Bands

This requirement must be applied to protect the in-building BS receivers operating in different bands. This requirement applies only to in-building BS.

The power of any spurious emission must not exceed the limit in Table 23 for an in-building BS.

Table 23 - Spurious Emission Limits for Protection of an In-Building BS Receiver

Protected SystemFrequency BandMaximum ValueBandwidth MeasurementNotesW-CDMA FDD 2100, E-UTRA band 11920 MHz to 1980 MHz-71 dBm100 kHzThis requirement does not apply to in-building BS operating in band 1 as 2.2.4.2.3 specifies these requirements.W-CDMA FDD 1800, E-UTRA band 31710 MHz to 1785 MHz-71 dBm100 kHzThis requirement does not apply to in-building BS operating in band 3 as 2.2.4.2.3 specifies these requirements.W-CDMA FDD 850824 MHz to 835 MHz-71 dBm100 kHzE-UTRA band 72500 MHz to 2570 MHz-71 dBm100 kHzThis requirement does not apply to in-building BS operating in band 7 as 2.2.4.2.3 specifies these requirements.W-CDMA FDD 900, E-UTRA band 8880 MHz to 915 MHz-71 dBm100 kHzThis requirement does not apply to in-building BS operating in band 8 as 2.2.4.2.3 specifies these requirements.E-UTRA band 382570 MHz to 2620 MHz-71 dBm100 kHzThis requirement does not apply to in-building BS operating in band 38 as 2.2.4.2.3 specifies these requirements.E-UTRA band 402300 MHz to 2400 MHz-71 dBm100 kHzThis requirement does not apply to in-building BS operating in band 40 as 2.2.4.2.3 specifies these requirements.

2.2.4.3. Measurement Method

Use the measurements specified in Article 3.3.3.

2.2.7. Spurious Receiver Emissions

2.2.5.1. Definitions

The maximum output power Pmax,c of the base station is the average power on a carrier frequency measured at the antenna connector throughout the ON cycle of the transmitter under specified standard conditions.

2.2.5.2. Limitations

- Under normal conditions: Prated,c - 2.7 ≤ Pmax,c ≤ Prated,c + 2.7;

- Under threshold conditions: Prated,c - 3.2 ≤ Pmax,c ≤ Prated,c + 3.2.

2.2.5.3. Measurement Method

Use the measurement methods prescribed in Article 3.3.4.

2.2.8. Blocking Characteristics

Customer assistance service is a service that provides answers to inquiries, advice, guidance on using the service, accepts requests, and provides information to customers about IPTV services on the fixed terrestrial telecommunications network.

The modulation transmission index is a measure of the transmitter's ability to eliminate signal formation in the nonlinear elements of the transmitter due to the appearance of the desired signal and interfering signals through the transmitter antenna. This index applies throughout the ON cycle of the transmitter and the transition cycle of the transmitter.

The modulation transmission level is the power of the modulation products when a modulated E-UTRA interference signal of 5 MHz channel bandwidth appears at the antenna connector with an average power level less than 30 dB below the average power level of the desired signal.

For BS capable of multi-band operation, where multiple bands are mapped onto separate antenna connectors, the single-band requirements apply independently of the relative positions of the interfering signals compared to the RF band protection spacing.

The desired signal is a single carrier, multi-carrier, or adjacent multi-carrier E-UTRA signal, for both contiguous and non-contiguous spectrum operations.

This requirement applies to all types of transmitters (single carrier or multi-carrier) and all transmission modes announced by the manufacturer.

2.2.6.2. Limitations

The channel bandwidth of the desired signal BWChannel is the maximum channel bandwidth.

Within the frequency range relevant to this requirement, the modulation transmission level does not exceed the unwanted emission limit specified in Articles 2.2.2.2, 2.2.3.2, and 2.2.4.2 when there is an interfering signal as defined in Table 24.

For BS operating in discontinuous spectrum, this requirement applies to the offset of interfering signals within the component block protection spacing, when the interfering signal lies entirely within the component block. The offset of the interfering signal is specified relative to the edges of the component block.

For BS capable of multi-band operation, this requirement applies to the edge of the RF band of each supported operating band of the base station. In cases where the inter-band RF protection spacing is less than 15 MHz, this requirement only applies to offsets of interfering signals within the protection spacing, when the interfering signal lies entirely within the inter-band RF protection spacing.

This requirement applies outside the base station RF band or the maximum radio band. The offset of the interfering signal is specified relative to the edges of the base station RF band or the maximum radio band.

Table 24 - Interfering and Desired Signals for Modulation Transmission Transmitter Equipment

ParameterValueOffset of the center frequency of the interfering signal from the low/high edge of the desired signal or the component block edge within the component block protection spacing±2.5 MHz±7.5 MHz±12.5 MHzNOTE: This requirement excludes positions of interfering signals that lie partially or completely outside the operating band of the base station downlink, except for positions of interfering signals that lie within the frequency range of adjacent operating bands in the same coverage area.

In cases where the positions of interfering signals do not comply with the provisions in Table 24, a channel bandwidth BWChannel smaller than the maximum channel bandwidth supported by the BS must satisfy that at least one position of the interfering signal meets the provisions in Table 24.

The measurement for the desired emission index for modulation transmission may be limited by the frequency ranges of all third-order or fifth-order modulation products, taking into account the width of these modulation products and excluding the desired bandwidth and the interfering signal bandwidth.

2.2.6.3. Measurement Method

Use the measurement methods prescribed in Article 3.3.5.

2.2.9. Receiver Modulation Characteristics

2.2.7.1. Definition

Receiver spurious emission power is the power of emissions generated or amplified in the receiver appearing at the BS antenna connector. The following requirements apply to all BS with separate RX and TX antenna ports. Testing must be performed when both TX and RX are turned on, with the TX port terminated.

For TDD BS with shared RX and TX antenna ports, these requirements apply throughout the OFF cycle of the transmitter. For FDD BS with shared RX and TX antenna ports, the spurious emission limits of the transmitter are specified in Article 2.2.4.

For BS capable of multi-band operation, where multiple bands are mapped onto separate antenna connectors, the single-band requirements apply and the excluded frequency bands apply only to the supported operating band on each antenna connector.

2.2.7.2. Limitations

The power of any spurious emission shall not exceed the limits specified in Table 25.

In addition to the requirements in Table 25, the power of any spurious emission shall not exceed the provisions in 2.2.4.2.2 and 2.2.4.2.3.

Table 25 - Spurious Emission Measurement Requirements

Frequency BandMaximum ValueMeasurement BandwidthNote30 MHz to 1 GHz-57 dBm100 kHz 1 GHz to 12.75 GHz-47 dBm1 MHz NOTE: Except for frequencies within 2.5 x BWChannel below the first carrier frequency to 2.5 x BWChannel above the last carrier frequency used by the BS transmitter, where BWChannel is the channel bandwidth specified in ETSI TS 136 141, Table 5.6-1. Additionally, except for frequencies greater than 10 MHz below the lowest supported downlink operating band frequency or above the highest supported downlink operating band frequency (see Table 1).For BS capable of multi-band operation, the excluded frequency bands apply to all supported operating bands. For BS capable of multi-band operation, where multiple bands are mapped onto separate antenna connectors, the single-band requirements and excluded frequency bands apply only to the supported operating band on each antenna connector.

2.2.7.3. Measurement Method

Use the measurement methods prescribed in Article 3.3.6.

2.2.10. Adjacent Channel Selectivity (ACS) and Narrowband Blocking

2.2.8.1. Definition

Blocking characteristics are measurements of the receiver's ability to receive the desired signal at the channel frequency of that receiver when there is unwanted interference at frequencies 1.4 MHz, 3 MHz, or 5 MHz from the E-UTRA signal for in-band blocking or from the CW signal for out-of-band blocking. The interfering E-UTRA signal is specified in Appendix C of ETSI TS 136 141.

2.2.8.2. Limits

Throughput must be ≥ 95% of the maximum throughput of the reference channel, with a desired signal and a coupled interfering signal applied to the antenna input of the BS using the parameters in Table 29 and Tables 26, 27, 28, or 30, depending on the class of base station declared and the operating band. The reference channel for the desired signal is the channel measured for each channel bandwidth specified in Tables 7.2-1, 7.2-2, 7.2-2, or 7.2-4 of ETSI TS 136 141, depending on the class of base station and defined in Appendix A of ETSI TS 136 141.

Blocking requirements apply outside the base station RF bandwidth or the maximum radio bandwidth. The offset of the interfering signal is specified relative to the edges of the base station RF bandwidth and the edges of the maximum radio bandwidth.

For a BS operating within non-contiguous spectrum bands within any operating band, if the guard band component size is wider than or equal to twice the offset of the interfering signal in Table 29, additional blocking requirements apply within any guard band component. The offset of the interfering signal is specified relative to the edges of the guard band component.

For a BS capable of multi-band operation, the in-band blocking requirements apply to each supported operating band within the frequency ranges specified in the in-band blocking bands. If the inter-band RF guard band size is wider than or equal to twice the offset of the interfering signal in Table 29, additional blocking requirements apply within any inter-band RF guard band.

For a BS capable of multi-band operation, the out-of-band blocking requirements apply to each operating band. Out-of-band blocking requirements do not apply to the in-band blocking frequency ranges specified in Tables 26, 27, and 30 for supported operating bands.

Table 26 - Blocking characteristic requirements for wide-area BS

Operating BandCentral frequency of interfering signal (MHz) (See Note 1)Average power of interfering signal (dBm)Average power of desired signal (dBm) (See Note 2)(*)(MHz) (See Note 4)Type of interfering signal1, 3, 7, 38, 40(FUL_low - 20) to (FUL_high + 20)-43PREFSES + 6 dB (Note 3)See Table 29See Table 291 to (FUL_low - 20)(FUL_high + 20) to 12 750-15PREFSENS + 6 dB-Carrier CW8(FUL_low - 20) to (FUL_high + 10)-43PREFSENS + 6 dB (Note 3)See Table 29See Table 291 to (FUL_low - 20)(FUL_high + 10) to 12 750-15PREFSENS + 6 dB-Carrier CWNOTE 1: FUL_low and FUL_high are the lowest and highest frequencies of the uplink operating band and are defined in Table 1.NOTE 2: PREFSENS depends on the channel bandwidth as defined in Clause 7.2 of ETSI TS 136 141.NOTE 3: For a BS capable of multi-band operation, the average power of the desired signal is PREFSENS + 1.4 dB when the interfering signal is not within the in-band blocking frequency range of the operating band when the desired signal is present.NOTE 4: (*) is the minimum frequency offset of the central frequency of the interfering signal from the lower/upper edge of the base station RF bandwidth or the guard band component edge outside the guard band component.

Table 27 - Blocking characteristic requirements for local BS

Operating BandCentral frequency of interfering signal (MHz) (See Note 1)Average power of interfering signal (dBm)Average power of desired signal (dBm) (See Note 2)(*)(MHz) (See Note 4)Type of interfering signal1, 3, 7, 38, 40(FUL_low - 20) to (FUL_high + 20)-35PREFSES + 6 dB (Note 3)See Table 29See Table 291 to (FUL_low - 20)(FUL_high + 20) to 12 750-15PREFSENS + 6 dB-Carrier CW8(FUL_low - 20) to (FUL_high + 10)-35PREFSENS + 6 dB (Note 3)See Table 29See Table 291 to (FUL_low - 20)(FUL_high + 10) to 12 750-15PREFSENS + 6 dB-Carrier CWNOTE 1: FUL_low and FUL_high are the lowest and highest frequencies of the uplink operating band and are defined in Table 1.NOTE 2: PREFSENS depends on the channel bandwidth as defined in Clause 7.2 of ETSI TS 136 141.NOTE 3: For a BS capable of multi-band operation, the average power of the desired signal is PREFSENS + 1.4 dB when the interfering signal is not within the in-band blocking frequency range of the operating band when the desired signal is present.NOTE 4: (*) is the minimum frequency offset of the central frequency of the interfering signal from the lower/upper edge of the base station RF bandwidth or the guard band component edge outside the guard band component.

Table 28 - Blocking characteristic requirements for indoor BS

Operating BandCentral frequency of interfering signal (MHz) (See Note 1)Average power of interfering signal (dBm)Average power of desired signal (dBm) (See Note 2)(*)(MHz) (See Note 4)Type of interfering signal1, 3, 7, 38, 40(FUL_low - 20) to (FUL_high + 20)-27PREFSES + 14 dBSee Table 29See Table 291 to (FUL_low - 20)(FUL_high + 20) to 12 750-15PREFSENS + 14 dB-Carrier CW8(FUL_low - 20) to (FUL_high + 10)-27PREFSENS + 14 dBSee Table 29See Table 291 to (FUL_low - 20)(FUL_high + 10) to 12 750-15PREFSENS + 14 dB-Carrier CWNOTE 1: FUL_low and FUL_high are the lowest and highest frequencies of the uplink operating band and are defined in Table 1.NOTE 2: PREFSENS depends on the channel bandwidth as defined in Clause 7.2 of ETSI TS 136 141.NOTE 3: (*) is the minimum frequency offset of the central frequency of the interfering signal from the edge of the desired signal channel.

Table 29 - Interfering signals for blocking characteristic requirements

E-UTRA Carrier Bandwidth (MHz)Minimum Frequency Offset of Central Interference Signal from Lower/Band Edge of Base Station RF Bandwidth or Component Block Protection Band (MHz)Type of Interference Signal5±7,5E-UTRA 5 MHz Signal10±7,5E-UTRA 5 MHz Signal15±7,5E-UTRA 5 MHz Signal20±7,5E-UTRA 5 MHz Signal

Table 30 - Blocking Characteristic Requirements for Wide Service Area Base Stations

Operating BandCentral Frequency of Interference Signal (MHz) (See Note 1)Average Power of Interference Signal (dBm)Average Power of Desired Signal (dBm) (See Note 2)(*) (MHz) (See Note 4)Type of Interference Signal1, 3, 7, 38, 40(FUL_low - 20) to (FUL_high + 20)-38PREFSES + 6 dB (Note 3)See Table 29See Table 291 to (FUL_low - 20)(FUL_high + 20) to 12 750-15PREFSENS + 6 dB-Carrier CW8(FUL_low - 20) to (FUL_high +10)-38PREFSENS + 6 dB (Note 3)See Table 29See Table 291 to (FUL_low - 20)(FUL_high + 10) to 12 750-15PREFSENS + 6 dB-Carrier CWNOTE 1: FUL_low and FUL_high are the lowest and highest frequencies of the uplink operating band and are defined in Table 1.NOTE 2: PREFSENS depends on the channel bandwidth as specified in Article 7.2 of ETSI TS 136 141.NOTE 3: For a base station capable of multi-band operation, the average power of the desired signal equals PREFSENS + 1.4 dB when the interference signal does not fall within the intra-band blocking band of the operating band with the desired signal present.NOTE 4: (*) is the Minimum Frequency Offset of the Central Interference Signal from the Lower/Upper Edge of the Base Station RF Bandwidth or the Component Block Protection Band.

2.2.8.3. Measurement Method

Use the measurements prescribed in Article 3.3.7.

2.2.11. Indoor Output Power of the Base Station for Protecting the Adjacent UTRA Channel

2.2.9.1. Definition

The mixing of third and higher order harmonics of two RF interference signals may generate interference signals within the band of the desired channel. The removal of intermodulation response is a measure of the receiver's ability to receive a desired signal at the assigned frequency of that channel in the presence of two related frequency interference signals. The interference signal may be a CW signal or an E-UTRA signal as defined in Appendix C of ETSI TS 136 141.

2.2.9.2. Limits

The throughput of each E-UTRA carrier shall be greater than or equal to 95% of the maximum throughput of the reference channel, with a desired signal at the assigned channel frequency and two interference signals under the conditions specified in Tables 31 and 32 for intermodulation performance and Tables 33,

34, 35, or 36 for narrowband intermodulation for the declared base station classes. The reference channel for the desired signal is defined in Tables 7.2-1, 7-2-2, or 7.2-3 of ETSI TS 136 141 for each channel bandwidth and in Appendix A of ETSI TS 136 141.

The intermodulation requirements for the receiver always apply outside the base station RF bandwidth or the maximum radio bandwidth. The offset of the interference signal is defined relative to the edges of the base station RF bandwidth and the maximum radio bandwidth.

For a base station operating in non-contiguous spectrum within any operating band, if the component block protection band is wider than or equal to the E-UTRA channel bandwidth of the interference signal in Table 32, additional narrowband intermodulation requirements apply within any component block protection band. The offset of the interference signal is defined relative to the edges of the component blocks within the component block protection band. This requirement applies to all component blocks.

For a base station capable of multi-band operation, the intermodulation requirements apply within any inter-RF bandwidth, where the size of the protection band must be wider than or equal to twice the frequency offset of the central E-UTRA interference signal from the edge of the base station RF bandwidth.

For a base station capable of multi-band operation, the narrowband intermodulation requirements apply within any inter-RF bandwidth protection band, where the size of the protection band is wider than or equal to the E-UTRA interference signals specified in Tables 33,

34, or 36. The offset of the interference signal is defined relative to the edges of the base station RF bandwidth within the inter-RF bandwidth protection band.

Table 31 - Intermodulation Requirements

BSC ClassAverage Power of Desired Signal (dBm)Average Power of Interference SignalType of Interference SignalWide Service Area BS PREFERENCE + 6 dB (see note)-52 dBmSee Table 32Medium Service Area BS PREFERENCE + 6 dB (see note)-47 dBmLocal BS PREFERENCE + 6 dB (see note)-44 dBmIn-Building BS PREFERENCE + 14 dB (see note)-36 dBmNOTE: PREFERENCE depends on the channel bandwidth as specified in Article 7.2 of ETSI TS 136 141. For E-UTRA channel bandwidths of 10 MHz, 15 MHz, and 20 MHz, this requirement only applies to one FRC A1-3 (see A.1 of ETSI TS 136 141) mapped to the frequency band adjacent to the interference signals.

Table 32 - Interference Signals for Intermodulation Performance

Lowest/Highest Received E-UTRA Carrier Bandwidth (MHz)Frequency Offset of Central Interference Signal from Lower/Upper Edge of Base Station RF Bandwidth (MHz)Type of Interference Signal5±7,5CW± 17,5E-UTRA 5 MHz Signal10± 7,375CW± 17,5E-UTRA 5 MHz Signal15± 7,25CW± 17,5E-UTRA 5 MHz Signal20± 7,125CW± 17,5E-UTRA 5 MHz Signal

Table 33 - Narrowband Intermodulation Requirements for Wide Service Area Base Stations

E-UTRA Carrier Bandwidth (MHz) Lowest/Highest Obtainable Average Desired Signal Power (dBm) Average Interfering Signal Power (dBm) Central RB Interference Frequency Offset from Lower/Upper RF Band Edge of Base Station or In-Band Component Edge within a Component Protection Band (kHz) Type of Interfering Signal5PREFSENS + 6 dB (see Note 1)-52±360CW-52±1 060E-UTRA 5 MHz, 1 RB (see Note 2)10PREFSENS + 6 dB (see Notes 1 and 3)-52±325CW-52±1 240E-UTRA 5 MHz, 1 RB (see Note 2)15PREFSENS + 6 dB (see Notes 1 and 3)-52±380CW-52±1 600E-UTRA 5 MHz, 1 RB (see Note 2)20PREFSENS + 6 dB (see Notes 1 and 3)-52±345CW-52±1 780E-UTRA 5 MHz, 1 RB (see Note 2)NOTE 1: PREFSENS depends on the channel bandwidth specified in Article 7.2 of ETSI TS 136 141.NOTE 2: The interfering signal includes a resource block placed at a predetermined offset, with the channel bandwidth of the interfering signal adjacent to the lower/upper RF band edge of the base station.NOTE 3: This requirement applies only to an FRC A1-3 (see A.1 of ETSI TS 136 141) mapped to frequency bands adjacent to the interfering signals.

Table 34 - Narrowband Intermodulation Requirements for Local Base Stations

E-UTRA Carrier Bandwidth (MHz) Lowest/Highest Obtainable Average Desired Signal Power (dBm) Average Interfering Signal Power (dBm) Central RB Interference Frequency Offset from Lower/Upper RF Band Edge of Base Station or In-Band Component Edge within a Component Protection Band (kHz) Type of Interfering Signal5PREFSENS + 6 dB (see Note 1)-44±360CW-44±1 060E-UTRA 5 MHz, 1 RB (see Note 2)10PREFSENS + 6 dB (see Notes 1 and 3)-44±325CW-44±1 240E-UTRA 5 MHz, 1 RB (see Note 2)15PREFSENS + 6 dB (see Notes 1 and 3)-44±380CW-44±1 600E-UTRA 5 MHz, 1 RB (see Note 2)20PREFSENS + 6 dB (see Notes 1 and 3)-44±345CW-44±1 780E-UTRA 5 MHz, 1 RB (see Note 2)NOTE 1: PREFSENS depends on the channel bandwidth specified in Article 7.2 of ETSI TS 136 141.NOTE 2: The interfering signal includes a resource block placed at a predetermined offset, with the channel bandwidth of the interfering signal adjacent to the lower/upper RF band edge of the base station.NOTE 3: This requirement applies only to an FRC A1-3 (see A.1 of ETSI TS 136 141) mapped to frequency bands adjacent to the interfering signals.

Table 35 - Narrowband Intermodulation Requirements for Indoor Base Stations

E-UTRA Carrier Bandwidth (MHz) Lowest/Highest Obtainable Average Desired Signal Power (dBm) Average Interfering Signal Power (dBm) Central RB Interference Frequency Offset from Channel Edge of Desired Signal (kHz) Type of Interfering Signal5PREFSENS + 6 dB (see Note 1)-36±360CW-36±1 060E-UTRA 5 MHz, 1 RB (see Note 2)10PREFSENS + 6 dB (see Notes 1 and 3)-36325CW-361 240E-UTRA 5 MHz, 1 RB (see Note 2)15PREFSENS + 6 dB (see Notes 1 and 3)-36380CW-361 600E-UTRA 5 MHz, 1 RB (see Note 2)20PREFSENS + 6 dB (see Notes 1 and 3)-36345CW-361 780E-UTRA 5 MHz, 1 RB (see Note 2)NOTE 1: PREFSENS depends on the channel bandwidth specified in Article 7.2 of ETSI TS 136 141.NOTE 2: The interfering signal includes a resource block placed at a predetermined offset, with the channel bandwidth of the interfering signal adjacent to the lower/upper RF band edge of the base station.NOTE 3: This requirement applies only to an FRC A1-3 (see A.1 of ETSI TS 136 141) mapped to frequency bands adjacent to the interfering signals.

Table 36 - Narrowband Intermodulation Requirements for Base Stations with Medium Coverage Areas

E-UTRA Carrier Bandwidth (MHz) Lowest/Highest Obtainable Average Desired Signal Power (dBm) Average Interfering Signal Power (dBm) Central RB Interference Frequency Offset from Lower/Upper RF Band Edge of Base Station or In-Band Component Edge within a Component Protection Band (kHz) Type of Interfering Signal5PREFSENS + 6 dB (see Note 1)-47±360CW-47±1 060E-UTRA 5 MHz, 1 RB (see Note 2)10PREFSENS + 6 dB (see Notes 1 and 3)-47±325CW-47±1 240E-UTRA 5 MHz, 1 RB (see Note 2)15PREFSENS + 6 dB (see Notes 1 and 3)-47±380CW-47±1 600E-UTRA 5 MHz, 1 RB (see Note 2)20PREFSENS + 6 dB (see Notes 1 and 3)-47±345CW-47±1 780E-UTRA 5 MHz, 1 RB (see Note 2)NOTE 1: PREFSENS depends on the channel bandwidth specified in Article 7.2 of ETSI TS 136 141.NOTE 2: The interfering signal includes a resource block placed at a predetermined offset, with the channel bandwidth of the interfering signal adjacent to the lower/upper RF band edge of the base station.NOTE 3: This requirement applies only to an FRC A1-3 (see A.1 of ETSI TS 136 141) mapped to frequency bands adjacent to the interfering signals.

2.2.9.3. Measurement Method

Use the measurements specified in Article 3.3.8.

2.2.12. Indoor Output Power of the Base Station for Protecting the Adjacent E-UTRA Channel

2.2.10.1. Definition

Adjacent Channel Selectivity (ACS) and Narrowband Blocking are measures of the receiver's ability to receive a desired signal at the assigned channel frequency when an interfering signal from an adjacent channel is present at a specified frequency offset from the channel edge of a victim system. The interfering signals must be an E-UTRA signal defined in Appendix C of ETSI TS 136 141. For narrowband blocking, the interference signal is a single E-UTRA resource block.

2.2.10.2. Limits

Throughput must be ≥ 95% of the maximum throughput of the reference channel.

For wide-area base stations, the interfering signal and the desired signal are paired to the base station antenna input as specified in Tables 37 and 38 for narrowband blocking and Table 39 for ACS. The reference channel for the desired signal is specified in Table 7.2-1 of ETSI TS 136 141 for each channel bandwidth and in Appendix A of ETSI TS 136 141.

For base stations with average service areas, interfering signals and desired signals are paired to the base station antenna input as specified in Tables 37 and 38 for narrowband filtering and Table 42 for ACS. The standard measurement channel for the desired signal is specified in Table 7.2-4 of ETSI TS 136 141 for each channel bandwidth and is defined in Appendix A of ETSI TS 136 141.

For local base stations, interfering signals and desired signals are paired to the base station antenna input as specified in Tables 37 and 38 for narrowband filtering and Table 40 for ACS. The standard measurement channel for the desired signal is specified in Table 7.2-2 of ETSI TS 136 141 for each channel bandwidth and is defined in Appendix A of ETSI TS 136 141.

For indoor base stations, interfering signals and desired signals are paired to the base station antenna input as specified in Tables 37 and 38 for narrowband filtering and Table 41 for ACS. The standard measurement channel for the desired signal is specified in Table 7.2-3 of ETSI TS 136 141 for each channel bandwidth and is defined in Appendix A of ETSI TS 136 141.

Requirements for ACS and narrowband filtering apply outside the RF bandwidth of the base station or the maximum radio bandwidth. Requirements for the offset of interfering signals are specified relative to the edges of the RF bandwidth of the base station or the maximum radio bandwidth.

For a base station operating within non-contiguous spectrum bands within any operating band, if the size of the component block protection zone is greater than or equal to the interfering signal in Tables 39, 40, and 42, additional ACS requirements are added within any component block protection zone. The offset of the interfering signal from the edges of the component blocks within the protection zone is specified.

For a multi-band capable base station, if the size of the inter-RF bandwidth protection zone is greater than or equal to the E-UTRA interfering signal in Tables 39, 40, and 42, additional ACS requirements are added within any inter-RF bandwidth protection zone. The offset of the interfering signal from the edges of the base station RF bandwidth within the inter-RF bandwidth protection zone is specified.

For a base station operating within non-contiguous spectrum bands within any operating band, if the size of the component block protection zone is greater than or equal to the channel bandwidth of the E-UTRA interfering signal in Table 38, additional narrowband filtering requirements are added within any component block protection zone. The offset of the interfering signal from the edges of the component blocks within the protection zone is specified.

For a multi-band capable base station, if the size of the inter-RF bandwidth protection zone is greater than or equal to the E-UTRA interfering signal in Table 38, additional narrowband filtering requirements are added within any inter-RF bandwidth protection zone. The offset of the interfering signal from the edges of the base station RF bandwidth within the inter-RF bandwidth protection zone is specified.

Table 37 - Narrowband Filtering Requirements

Class BS Average Desired Signal Power (dBm) Average Interfering Signal Power Type of Interfering Signal Wide Area BS PREFSENS + 6 dB (see footnote) -49 dBm See Table 38 Medium Service Area BS PREFSENS + 6 dB (see footnote) -44 dBm Local BS PREFSENS + 6 dB (see footnote) -41 dBm Indoor BS PREFSENS + 14 dB (see footnote) -33 dBm FOOTNOTE: PREFSENS depends on the channel bandwidth as specified in Clause 7.2 of ETSI TS 136 141

Table 38 - Interfering Signals for Narrowband Filtering Requirements

Minimum/Maximum Carrier Bandwidth E-UTRA Channel (MHz) Frequency Offset of Central RB Interfering Signal from Lower/Upper Edge of Base Station RF Bandwidth or Component Block Within Protection Zone (MHz) Type of Interfering Signal 5 ± (342.5 + m x 180), m = 0, 1, 2, 3, 4, 9, 14, 19, 24 E-UTRA 5 MHz, 1RB (see footnote) 10 ± (347.5 + m x 180), m = 0, 1, 2, 3, 4, 9, 14, 19, 24 E-UTRA 5 MHz, 1RB (see footnote) 15 ± (352.5 + m x 180), m = 0, 1, 2, 3, 4, 9, 14, 19, 24 E-UTRA 5 MHz, 1RB (see footnote) 20 ± (342.5 + m x 180), m = 0, 1, 2, 3, 4, 9, 14, 19, 24 E-UTRA 5 MHz, 1RB (see footnote) FOOTNOTE: The interfering signal includes a resource block placed at a predetermined offset, with the interfering signal channel bandwidth adjacent to the lower/upper edge of the base station RF bandwidth. The frequency offsets are out-of-channel interfering signals.

Table 39 - Adjacent Channel Selectivity for Wide Area BS

Minimum/Maximum Carrier Bandwidth E-UTRA Channel (MHz) Average Desired Signal Power (dBm) Average Interfering Signal Power (dBm) Frequency Offset of Central RB Interfering Signal from Lower/Upper Edge of Base Station RF Bandwidth or Component Block Within Protection Zone (MHz) Type of Interfering Signal 5 PREFSENS + 6 dB (see footnote) -52 ± 2.5 0 25 E-UTRA 5 MHz 10 PREFSENS + 6 dB (see footnote) -52 ± 2.5 0 75 E-UTRA 5 MHz 15 PREFSENS + 6 dB (see footnote) -52 ± 2.5 125 E-UTRA 5 MHz 20 PREFSENS + 6 dB (see footnote) -52 ± 2.5 0 25 E-UTRA 5 MHz FOOTNOTE: PREFSENS depends on the channel bandwidth as specified in Clause 7.2 of ETSI TS 136 141. The frequency offsets are out-of-channel interfering signals.

Table 40 - Adjacent Channel Selectivity for Local BS

Minimum/Maximum Carrier Bandwidth E-UTRA Channel (MHz) Average Desired Signal Power (dBm) Average Interfering Signal Power (dBm) Frequency Offset of Central RB Interfering Signal from Lower/Upper Edge of Base Station RF Bandwidth or Component Block Within Protection Zone (MHz) Type of Interfering Signal 5 PREFSENS + 6 dB (see footnote) -44 ± 2.5 0 25 E-UTRA 5 MHz 10 PREFSENS + 6 dB (see footnote) -44 ± 2.5 0 75 E-UTRA 5 MHz 15 PREFSENS + 6 dB (see footnote) -44 ± 2.5 125 E-UTRA 5 MHz 20 PREFSENS + 6 dB (see footnote) -44 ± 2.5 0 25 E-UTRA 5 MHz FOOTNOTE: PREFSENS depends on the channel bandwidth as specified in Clause 7.2 of ETSI TS 136 141. The frequency offsets are out-of-channel interfering signals.

Table 41 - Adjacent Channel Selectivity for Indoor BS

E-UTRA channel bandwidth (MHz)Average desired signal power (dBm)Average desired signal-to-interference power (dBm)Central frequency offset of interfering signal from edge of desired signal channel (MHz)Type of interfering signal5PREFSENS + 22 dB (see footnote)-282,5025E-UTRA 5 MHz signal10PREFSENS + 22 dB (see footnote)-282,5075E-UTRA 5 MHz signal15PREFSENS + 22 dB (see footnote)-282,5125E-UTRA 5 MHz signal20PREFSENS + 22 dB (see footnote)-282,5025E-UTRA 5 MHz signalNOTES: PREFSENS depends on the channel bandwidth specified in Article 7.2 of ETSI TS 136 141. The frequency offset is an interfering signal outside the channel.

Table 42 - Adjacent channel selectivity for indoor base stations with average service area

Lowest/Highest E-UTRA carrier channel bandwidth obtained (MHz)Average desired signal power (dBm)Average desired signal-to-interference power (dBm)Central frequency offset of interfering signal from edge of desired signal channel (MHz)Type of interfering signal5PREFSENS + 6 dB (see footnote)-472,5025E-UTRA 5 MHz signal10PREFSENS + 6 dB (see footnote)-472,5075E-UTRA 5 MHz signal15PREFSENS + 6 dB (see footnote)-472,5125E-UTRA 5 MHz signal20PREFSENS + 6 dB (see footnote)-472,5025E-UTRA 5 MHz signalNOTES: PREFSENS depends on the channel bandwidth specified in Article 7.2 of ETSI TS 136 141. The frequency offset is an interfering signal outside the channel.

2.2.10.3. Measurement method

Use the measurements prescribed in Article 3.3.9.

2.2.13. Indoor Output Power of the Base Station for Protecting the Co-Channel E-UTRA

2.2.11.1. Definition

Indoor base stations must be capable of adjusting the transmitter output power to minimize adjacent channel interference while optimizing the coverage area of the indoor base station, in the case where an adjacent channel is licensed to another operator in the same geographic area. These requirements apply only to indoor base stations and apply under AWGN radio transmission conditions.

2.2.11.2. Limits

The output power Pout of the indoor base station must comply with the provisions in Table 43 under the following input conditions:

- CPICH Ec, measured in dBm, is the encoded power of the primary CPICH on one of the existing adjacent channels at the antenna connector of the indoor base station relative to the received CPICH on the adjacent channels. If CPICH primary spreading is applied, CPICH Ec equals the sum (W) of the encoded powers of the primary CPICH transmitted from each antenna.

- loh, measured in dBm, is the total received multiplexed power, including signals and interference but excluding the indoor base station's own signals present at the antenna connector of the indoor base station on the active channel.

The input conditions for the requirements in this section are defined at the antenna connector of the indoor base station. For indoor base station receivers that are multiplexed, the requirements apply separately to each individual antenna connector, with other antenna connectors terminated or disabled. These requirements do not change under different conditions. For indoor base stations without measurement capability, a standard antenna with zero gain (0 dBi) is assumed to convert power levels to field strength.

NOTES: This requirement tests the mandatory mechanism for the indoor base station's output power to protect adjacent UTRA channels, assuming there is an adjacent UTRA channel licensed to another operator that needs protection. For operating indoor base stations, if both adjacent channels are licensed to other operators, the strictest requirement applies to Pout. In cases where one adjacent channel is licensed to an E-UTRA operator while the other adjacent channel is licensed to a UTRA operator, the stricter requirement of this clause and Clause 2.2.11 applies to Pout. When both adjacent channels and the active channel of the indoor base station are licensed to the same operator, these requirements do not apply.

Table 43 - Output power of indoor base station to protect adjacent UTRA channel of another operator

Input conditionsOutput power, Poutloh > CPICH Ec + 43 dB and CPICH Ec ≥ -105 dBm≤ 10 dBmloh ≤ CPICH Ec + 43 dB and CPICH Ec ≥ -105 dBm≤ maximum (8 dBm, minimum (20 dBm, CPICH Ec + 100 dB))CPICH Ec < -105 dBm≤ 20 dBm

- Under normal operating conditions, the output power Pout of the indoor base station must be equal to or less than the value specified in Table 43 plus 2.7 dB;

- Under threshold operating conditions, the output power Pout of the indoor base station must be equal to or less than the value specified in Table 43 plus 3.2 dB.

2.2.11.3. Measurement method

Use the measurements prescribed in Article 3.3.10.

2.2.14. Standard Selectivity Level

2.2.12.1. Definition and applicability

Indoor base stations must be capable of adjusting the transmitter output power to minimize adjacent channel interference from licensed operators in the same geographic area while optimizing the coverage area of the indoor base station. These requirements apply only to indoor base stations and apply under AWGN radio transmission conditions.

2.2.12.2. Limits

The output power Pout of the indoor base station must comply with the provisions in Table 44 under the following input conditions:

- CRS Es, measured in dBm, is the received power of the reference signal on a resource element on one of the existing adjacent channels at the antenna connector of the indoor base station relative to the received reference signal on the adjacent channels. To determine CRS Es, the cell-specific reference signal R0 specified in ETSI TS 136 211 must be used. If the indoor base station detects multiple TX antennas being used to transmit on the adjacent channel, the average (W) of CRS Es across all detected antennas may be used.

- loh, measured in dBm, is the total received multiplexed power, including both signals and interference but excluding the indoor base station's own signals present at the antenna connector of the indoor base station on the active channel.

The input conditions for the requirements set forth herein are defined at the antenna connector of the indoor base station (BS). For the receivers of the indoor BS repeaters, these requirements apply to each individual antenna connector, with other connectors being terminated or disabled. These requirements do not change under different conditions. For indoor BSs that lack measurement capability, a standard antenna with a gain of 0 dBi is assumed to convert power levels to field strength.

NOTE: This requirement checks the mandatory mechanism for the output power of the indoor BS to protect the adjacent E-UTRA channel, assuming there is an adjacent E-UTRA channel licensed to another operator that needs protection. For operating indoor BSs where both adjacent channels are licensed to other operators, the strictest requirement is applied to Pout. In cases where one of the adjacent channels is licensed to an E-UTRA operator while the other adjacent channel is licensed to a UTRA operator, the stricter requirement of this clause and Clause 2.2.11 is applied to Pout. If both adjacent channels and the active channel of the indoor BS are licensed to the same operator, then the requirements of this clause do not apply.

Table 44 - Output Power of Indoor Base Station to Protect Adjacent E-UTRA Channel of Operator

Input ConditionsOutput Power, PoutCRS Es < -127 dBm≤ 20 dBm

loh > CRS Es + 10 · log10() + 30 dB and CRS Es ≥ -127 dBm

≤ 10 dBm

loh ≤ CRS Es + 10 · log10() + 30 dB and CRS Es ≥ -127 dBm

≤ max (8 dBm, min (20 dBm, CRS Es + 10 · log10(+ 85 dB))

- Under normal operating conditions, the output power Pout of the indoor BS must be equal to or less than the value specified in Table 44 plus 2.7 dB;

- Under threshold operating conditions, the output power Pout of the indoor BS must be equal to or less than the value specified in Table 44 plus 3.2 dB.

2.2.12.3. Measurement Method

Use the measurements prescribed in Clause 3.3.11.

2.2.15. Radiation Emissions

2.2.13.1. Definition and Applicability

To minimize downlink co-channel interference to nearby macro non-CSG UEs while optimizing the coverage area of the indoor CSG base station, the indoor BS may adjust its output power according to the requirements presented herein. The requirements in this clause may be applied to radio transmission conditions AWGN.

2.2.13.2. Limits

For indoor BSs supporting the requirements specified in this clause, the output power, Pout, of the indoor BS must comply with the provisions in Table 45 based on the following input conditions:

- CRS Es, measured in dBm, is the received power of the reference signal on the current resource element from the co-channel wide-area BS at the antenna connector of the indoor BS receiver. To determine CRS Es, the characteristic cell-specific reference signal (RO) specified in ETSI TS 136 211 must be used. If the indoor BS detects multiple TX antenna ports being used by the co-channel wide-area BS for transmission, the average value (W) of CRS Es across all detected TX antenna ports, including R0, may be used.

- loh, measured in dBm, is the total downlink received power, including all interference but excluding the signal of the indoor BS itself, present at the antenna connector of the indoor BS on the active channel.

- lob, measured in dBm, is the uplink interference received power, including thermal noise, within the physical resource block bandwidth of the resource elements defined in ETSI TS 136 214, present at the antenna connector of the indoor BS on the active channel. The input conditions for the requirements specified in this clause are defined at the antenna connector of the indoor BS. For the receivers of the indoor BS repeaters, these requirements apply to each individual antenna connector, with other connectors being terminated or disabled. The requirements do not change under different conditions. For indoor BSs lacking measurement capability, a standard antenna with a gain of 0 dBi is assumed to convert power levels to field strength.

Table 45 - Output Power of Indoor Base Station to Protect Co-Channel E-UTRA Channel

Input ConditionsOutput Power, PoutOption 1: CRS Es < -127 dBm orOption 2: CRS Es < -127 dBm and lob > -103 dBm≤ 20 dBm

loh (DL) > CRS Es + 10 · log

) + 30 dB and10(Option 1: CRS Es ≥ -127 dBm or

Option 2: CRS Es ≥ -127 dBm and

lob > -103 dBm

loh (DL) > CRS Es + 10 · log

≤ 10 dBm

Option 2: CRS Es ≥ -127 dBm and lob > -103 dBm10(Option 1: CRS Es ≥ -127 dBm or

Option 2: CRS Es ≥ -127 dBm and

≤ max (8 dBm, min (CRS Es + P

10 · logmax,c30 dB ≤ X ≤ 70 dB10())

Pmin = -10 dBm

- Under normal operating conditions, the output power Pout of the indoor BS must be equal to or less than the value specified in Table 45 plus 2.7 dB;

- Under threshold operating conditions, the output power Pout of the indoor BS must be equal to or less than the value specified in Table 45 plus 3.2 dB.

2.2.13.3. Measurement Method

Use the measurements prescribed in Clause 3.3.12.

2.2.14.1. Definition

3.1. Measurement Conditions

The selected reference power level PREFSENS is the minimum average power obtained at the antenna connector, where a throughput requirement must be met for a specified reference measurement channel.

2.2.14.2. Limits

For each measured E-UTRA carrier, the throughput must be ≥ 95% of the maximum throughput of the specified reference measurement channel in Clause A.1 of ETSI TS 136 141 with the parameters specified in Table 46 for wide-area BSs, Table 47 for local BSs, Table 48 for indoor BSs, and Table 49 for BSs with medium service areas.

Table 46 - Selected Reference Power Levels for Wide-Area BSs

E-UTRA Channel Bandwidth (MHz)Reference Measurement ChannelPREFSENS (dBm)5FRC A1-3 Clause A.1 (see note)-100.810FRC A1-3 Clause A.1 (see note)-100.815FRC A1-3 Clause A.1 (see note)-100.820FRC A1-3 Clause A.1 (see note)-100.8NOTE: PREFSENS is the power level of a specific reference measurement channel case. This requirement will be met for each successive application of a FRC A1-3 case mapped to separate frequency bands with a width of 25 resource blocks each.

E-UTRA Channel Bandwidth (MHz)Standard Measurement ChannelPREFSENS Selected Power Level (dBm)5FRC A1-3 Clause A.1 (see note)-100,810FRC A1-3 Clause A.1 (see note)-100,815FRC A1-3 Clause A.1 (see note)-100,820FRC A1-3 Clause A.1 (see note)-100,8NOTE: PREFSENS is the power level of a standard measurement channel. This requirement will be met for each successive application of a case FRC A1-3 mapping to separate frequency bands with a width of 25 resource blocks each.

Table 47 - Selection Levels in Local Base Stations

Channel Bandwidth E-UTRA (MHz)Reference ChannelSelection Power Level, PREFSENS (dBm)5FRC A1-3 Article A.1 (see footnote)-92.810FRC A1-3 Article A.1 (see footnote)-92.815FRC A1-3 Article A.1 (see footnote)-92.820FRC A1-3 Article A.1 (see footnote)-92.8NOTES: PREFSENS is the power level of a reference channel. This requirement will be met for each successive application of a case FRC A1-3 mapped to separate frequency bands with a width of 25 resource blocks each.

Table 48 - Standard Selection Levels for Indoor Base Stations

Channel Bandwidth E-UTRA (MHz)Reference ChannelSelection Power Level, PREFSENS (dBm)5FRC A1-3 Article A.1 (see footnote)-92.810FRC A1-3 Article A.1 (see footnote)-92.815FRC A1-3 Article A.1 (see footnote)-92.820FRC A1-3 Article A.1 (see footnote)-92.8NOTES: PREFSENS is the power level of a reference channel. This requirement will be met for each successive application of a case FRC A1-3 mapped to separate frequency bands with a width of 25 resource blocks each.

Table 49 - Standard Selection Levels for Wide Coverage Base Stations

Channel Bandwidth E-UTRA (MHz)Reference ChannelStandard Selection Power Level, PREFSENS (dBm)5FRC A1-3 Article A.1 (see footnote)-95.810FRC A1-3 Article A.1 (see footnote)-95.815FRC A1-3 Article A.1 (see footnote)-95.820FRC A1-3 Article A.1 (see footnote)-95.8NOTES: PREFSENS is the power level of a reference channel. This requirement will be met for each successive application of a case FRC A1-3 mapped to separate frequency bands with a width of 25 resource blocks each.

2.2.14.3. Measurement Method

Use the measurements specified in Article 3.3.13.

3.2. Interpretation of Measurement Results

2.2.15.1. Definition

This parameter evaluates spurious radiation from the base station's port housing. For multi-port base stations, the base station with the digital radio unit and the radio unit may be measured separately.

2.2.15.2. Limits

Frequency band and standard bandwidths for transitions between out-of-band emission requirements and spurious emissions comply with ITU-R SM.329-12 and SM.1539-1 recommendations.

Table 50 specifies the limits on spurious radiation emissions from the base station. The requirements in this table apply to frequencies within the emission range.

Table 50 - Requirements for Spurious Radiation Emissions

FrequencyMinimum Requirement (E.R.P)/Standard BandwidthAvailability30 MHz ≤ f < 1 000 MHz-36 dBm/100 kHzAll1 GHz ≤ f< 12.75 GHz-30 dBm/1 MHzAll

2.2.15.3. Measurement Method

Use the measurements specified in Article 3.3.14.

3. MEASUREMENT METHODS

3.3. Essential Parameters for the Wireless Part

The measurements defined in this standard must be performed at representative points within the boundary conditions of the declared operational environment.

At points where technical parameters vary depending on environmental conditions, measurements must be conducted under diverse environmental conditions (within the boundary conditions of the declared operational environment) to verify compliance with affected technical requirements.

Generally, all measurements must be carried out under normal measurement conditions unless otherwise specified. Appendix B can be referred to for using different measurement conditions to check compliance.

This specifies the measurement methods for E-UTRA (FDD and TDD).

Measurement configurations and channel bandwidths for multi-carrier operations must conform to the provisions of Articles 4.10, 5.7.1, and 5.7.1A of ETSI TS 136 141.

Typically, all measurements must be performed with the lowest and highest supported bandwidths, unless otherwise specified. In cases where measurements are not performed, the manufacturer must declare applicability for all other supported bandwidths.

In single-carrier scenarios, multiple measurements are conducted at appropriate frequencies at the end, middle, and beginning of the base station's operating frequency band. These frequencies are designated as B (end), M (middle), and T (beginning) of the RF channels and are defined in Article 4.7 of ETSI TS 136 141.

In single-band multi-carrier scenarios, multiple measurements are conducted at the maximum RF bandwidth of the base station at the end, middle, and beginning of the supported frequency range in each operating band. These frequencies are designated as BRFBW (end), MRFBW (middle), and TRFBW (beginning) for non-aggregated channels and are defined in Article 4.7.1 of ETSI TS 136 141.

In dual-band scenarios, multiple measurements are conducted at the RF bandwidth of the base station at the end of the supported frequency range in the lower operating band and at the beginning of the supported frequency range in the upper operating band. These frequencies are designated as BRFBW_T’RFBW and B’RFBW_TRFBW and are defined in Article 4.7.1 of ETSI TS 136 141.

The measurement systems specified for each measurement are described in Appendix C.

3.3.1. Unwanted Emissions within the Operating Band

The results recorded in the measurement report of the measurements prescribed in this standard must be explained as follows:

- The measured value relates to the corresponding limit used to determine whether the equipment meets the standard requirements;

- The measurement uncertainty value for each parameter measurement must be included in the measurement report;

- For each measurement, the recorded measurement uncertainty value must be less than or equal to the value given in Table 51.

According to this standard, in measurement methods, these uncertainty values must be calculated according to ETSI TR 100 028, specifically in Appendix D of ETSI TR 100 028-2, and must correspond to an expansion factor (coverage factor) k = 1.96 or k = 2 (this factor specifies a confidence level of 95% and 95.45% in the case of actual measurement uncertainty distributions that are Gaussian).

Table 51 is based on this expansion factor.

Table 51 - Maximum Measurement Uncertainty of the Measurement System

ParametersConditionsNon-complianceUnwanted emissions within operating band ±1.5 dBTx adjacent channel power leakage ratio (ACLR)ACLR ±0.8 dBFor absolute power requirements ±2.0 dBCACLR ±0.8 dBFor absolute power requirements ±2.0 dBTransmitter spurious emissionsFor "Spurious emissions" 9 kHz < f ≤ 4 GHz ±2.0 dB4 GHz -60 dBm) ±2.0 dBFor coexistence requirements (≥ -60 dBm) ±3.0 dBFor base station receiver protection ±3.0 dBRadio transmitter maximum output power ±0.7 dBModulation passbandFor unwanted emissions within operating band ±2.5 dBFor ACLR ±2.2 dBFor "Spurious emissions": f ≤ 2.2 GHz ±2.5 dB2.2 GHz < f ≤ 4 GHz ±2.8 dBf >4 GHz ±4.5 dBFor coexistence requirements ±2.8 dBInterference signal ±1.0 dBReceiver spurious emissions 30 MHz ≤ f ≤ 4 GHz ±2.0 dB4 GHz < f ≤ 19 GHz ±4.0 dBBlocking characteristicsIn-band blocking using modulated interference ±1.6 dBOut-of-band blocking using CW interference: 1 MHz < finterferer ≤ 3 GHz ±1.3 dB3 GHz < finterferer ≤ 4.2 GHz ±1.6 dB4.2 GHz < finterferer ≤ 12.75 GHz ±3.2 dBReceiver modulation passband characteristics ±1.8 dBAdjacent channel selectivity (ACS) and narrowband blocking ±1.4 dBFrequency response standard ±0.7 dBNOTE 1: For RF measurements, it should be noted that the non-compliance in Table 51 applies to the measurement system operating with a nominal 50 Ω load and does not take into account the effects of the system due to the mismatch between the EUT and the measurement system.NOTE 2: Appendix G of TR 100 028-2 provides guidance on calculating components of non-compliance related to mismatch.NOTE 3: If the measurement system has a measurement uncertainty greater than the measurement uncertainty specified in Table 51, the equipment may still be used provided that the following adjustments are made: Any additional non-compliance in the measurement system exceeding the measurement uncertainty specified in Table 51 is used to tighten the limits - making the measurement more difficult to pass (for some measurements, such as receiver measurements, this may require changes to the stimulus signals). This procedure ensures that a measurement system that does not comply with Table 51 does not increase the probability of passing an EUT in the case of erroneous measurements.

3.3.2. Adjacent Channel Leakage Ratio (ACLR)

3.3.3. Spurious Transmitter Emissions

3.3.1.1. Initial Conditions

Measurement Environment: Normal; see Clause B1, Appendix B.

The RF channels required for single-carrier measurements: B, M, and T; see Clause 3.1.

The RF bandwidth positions of the base station that need to be measured:

- BRFBW, MRFBW, and TRFBW at single-band operation; see Clause 3.1.

- BRFBW_T'RFBW and B'RFBW_TRFBW at multi-band operation; see Clause 3.1.

Measurement Setup:

1) Connect the signal analyzer to the base station antenna port according to Clause C.1.1, Appendix C.

Generally, the resolution bandwidth of the measuring instrument must equal the measurement bandwidth. However, to increase accuracy, sensitivity, and measurement performance, and to avoid carrier leakage, etc., the resolution bandwidth may be smaller than the measurement bandwidth. When the resolution bandwidth is smaller than the measurement bandwidth, the results must be integrated over the measurement bandwidth to obtain the equivalent noise bandwidth of the measurement bandwidth.

2) Carrier separation mode: RMS voltage.

3.3.1.2. Measurement Procedure

1) For a base station capable of single-carrier operation only, set up the base station to transmit signals according to E-TM1.1 of ETSI TS 136 141 at the rated output power Prated,c as specified by the manufacturer.

For a base station capable of multi-carrier operation, set up the base station to transmit signals according to E-TM1.1 on all configured carriers using the test model and corresponding power settings as specified in Clauses 4.10 and 4.11 of ETSI TS 136 141.

2) Tune the center frequency of the measurement filter in steps and measure the emissions in the designated frequency bands with the specified measurement bandwidth. For base stations operating in multiple bands or non-contiguous spectra, emissions in the inter-band RF or component guardband must be measured using the specified measurement bandwidth from the edge of the base station RF bandwidth or the nearest component guardband.

3) Repeat the measurements with the channel setup according to E-TM1.2 of ETSI TS 136 141.

Additionally, the following applies to a base station capable of multi-band operation:

4) For single-band and multi-carrier base stations, repeat the above steps for each relevant band where the single-band measurement setups and test models apply to carriers not active in other bands. For multi-band base stations with separate antenna ports, do not perform measurements when the single-band or multi-band antenna ports are terminated.

3.3.4. Maximum Output Power of the Base Station

3.3.2.1. Initial Conditions

Measurement Environment: Normal: see Clause B1, Appendix B.

The RF channels required for single-carrier measurements: B, M, and T; see Clause 3.1.

The RF bandwidth positions of the base station that need to be measured:

- BRFBW, MRFBW, and TRFBW at single-band operation; see Clause 3.1.

- BRFBW_T'RFBW and B'RFBW_TRFBW at multi-band operation; see Clause 3.1.

Measurement Setup:

1) Connect the measuring equipment to the base station antenna port according to Clause C.1.1, Appendix C.

2) The characteristics of the measuring equipment must be:

- Measurement filter bandwidth: specified in Clause 2.2.3.2.

- Carrier separation mode: RMS voltage or actual average power.

3) For a base station capable of single-carrier operation only, set up the base station to transmit signals according to E-TM1.1 of ETSI TS 136 141 at the rated output power Prated,c as specified by the manufacturer. For a base station capable of multi-carrier operation, set up the base station to transmit signals according to E-TM1.1 on all configured carriers using the test model and corresponding power settings as specified in Clauses 4.10 and 4.11 of ETSI TS 136 141.

4) Set the carrier frequency within the supported frequency band.

3.3.2.2. Measurement Procedure

1) Measure the adjacent channel power leakage ratio for frequency offsets on both sides of the channel frequency according to Table 13 (for paired spectrum) or Table 14 (for unpaired spectrum) respectively. In the case of multiple carriers, only measure the frequencies below the lowest carrier frequency and above the highest carrier frequency transmitted.

2) For ACLR requirements applicable within the component guardband for non-contiguous spectrum operation or within the inter-band RF guardband for multi-band operation:

a) Measure ACLR within the component guardband or inter-band RF guardband according to Clause 2.2.3.2.1 if feasible;

b) Measure the CACLR inside the protection band of the component block or the RF bandwidth protection interval as specified in Article 2.2.3.2.2, if feasible.

3) Repeat the measurements with the channel setup according to E-TM1.2 of ETSI TS 136 141.

Additionally, the following applies to a base station capable of multi-band operation:

4) For single-band and multi-carrier base stations, repeat the above steps for each relevant band where the single-band measurement setups and test models apply to carriers not active in other bands. For multi-band base stations with separate antenna ports, do not perform measurements when the single-band or multi-band antenna ports are terminated.

3.3.5. Transmitter Modulation Characteristics

3.3.3.1. Initial Conditions

Measurement Environment: Normal; see Clause B1, Appendix B.

The RF channels required for single-carrier measurements: B, M, and T; see Clause 3.1.

The RF bandwidth positions of the base station that need to be measured:

- BRFBW, MRFBW, and TRFBW at single-band operation; see Clause 3.1.

- BRFBW_T'RFBW and B'RFBW_TRFBW at multi-band operation; see Clause 3.1.

Measurement Setup:

1) Connect the antenna port of the BS to the receiver measurement device according to Article C.1.1 of Appendix C, using an attenuator or directional coupler if necessary.

2) The measurements must use the measurement bandwidth according to the conditions specified in Article 6.6.4 of ETSI TS 136 104.

3) Carrier separation mode: actual RMS voltage.

4) For BSs declared capable of operating only on a single carrier, configure the BS with the transmitter operating at its maximum output power as declared for single-carrier operation.

For BSs declared capable of multi-band operation, set up the base station transmitter according to E-TM 1.1 on all configured carriers as described in the test configuration in Article 4.10 of ETSI TS 136 141.

3.3.3.2. Measurement Procedure

1) Set the BS to transmit a signal according to E-TM1.1 of ETSI TS 136 141 at the maximum output power as published by the manufacturer.

2) Measure emissions at the designated frequencies with the designated measurement bandwidth, and the measured values shall not exceed the specified limits.

Additionally, the following applies to a base station capable of multi-band operation:

3) For single-band tests and BSs capable of multi-band operation, repeat the above steps for each relevant band where the single-band measurement conditions and test models apply to carriers not active on other bands. For multi-band capable BSs with separate antenna ports, do not perform testing when the single-band or multi-band antenna ports are terminated.

3.3.6. Spurious Receiver Emissions

3.3.4.1. Initial Conditions

Test environment: Normal; see Article B.1 of Appendix B.

The RF channels required for single-carrier measurements: B, M, and T; see Clause 3.1.

The RF bandwidth positions of the base station that need to be tested for multiple carriers:

- BRFBW, MRFBW, and TRFBW at single-band operation; see Clause 3.1.

- BRFBW_T'RFBW and B'RFBW_TRFBW at multi-band operation; see Clause 3.1.

Additionally, on only one RF bandwidth position of the base station or RF channel, testing must be performed with the limited supply defined in Article B.4 of Appendix B.

NOTE: Testing with limited supply also includes testing with limited temperature, see Article B.2 of Appendix B.

Measurement Setup:

1) Connect the power meter to the base station's antenna port as specified in Article C.1.1 of Appendix C.

3.3.4.2. Measurement Procedure

1) For a BS declared capable of operating only on a single carrier, set up the base station transmitter according to E-TM 1.1 in ETSI TS 136 141.

For a BS declared capable of operating on multiple carriers, set up the base station transmitter according to E-TM 1.1 on all configured carriers using the corresponding test setup configurations and powers as specified in Articles 4.10 and 4.11 of ETSI TS 136 141.

2) Measure the average power for each carrier at the antenna port.

Additionally, the following steps apply for a multi-carrier BS:

3) For single-band tests and multi-carrier BSs, repeat the above steps for each relevant band where the single-band test setups and test models apply to carriers not active on other bands. For multi-carrier capable BSs with separate antenna ports, do not perform testing when the single-band or multi-band antenna ports are terminated.

3.3.7. Blocking Characteristics

3.3.5.1. Initial Conditions

Test environment: Normal; see Article B.1 of Appendix B.

The RF channels required for single-carrier measurements: B, M, and T; see Clause 3.1.

The RF bandwidth positions of the base station that need to be tested for multiple carriers: BRFBW, MRFBW, and TRFBW; see Article 3.1. The desired channel bandwidth BWChannel is the maximum channel bandwidth supported by the base station.

Measurement Setup:

1) Connect the signal analyzer to the base station's antenna port as specified in Article C.1.2 of Appendix C.

3.3.5.2. Measurement Procedure

1) For a BS declared capable of operating only on a single carrier, set up the base station transmitter according to E-TM 1.1 in ETSI TS 136 141 at the rated output power Prated,c as published by the manufacturer.

For a BS declared capable of operating on multiple carriers, set up the base station transmitter according to E-TM 1.1 on all configured carriers using the corresponding test setup configurations and powers as specified in Articles 4.10 and 4.11 of ETSI TS 136 141.

2) Generate interference signals according to E-TM1.1 in ETSI TS 136 141, with a central frequency offset and channel bandwidth of 5 MHz under the conditions in Table 24 but excluding interference frequencies outside the defined downlink operating band, or interference frequencies not fully within the component block protection band or the RF bandwidth protection interval.

3) Adjust ATT1 so that the E-UTRA interference signal level complies with Article 2.2.6.2.

4) Perform out-of-band emission measurements according to Articles 3.3.1 and 3.3.2 for all third and fifth-order intermodulation components appearing in the frequency ranges defined in Articles 3.3.1 and 3.3.2. The width of the intermodulation components must be taken into account.

5) Perform spurious emission measurements according to Article 3.3.3 for all third and fifth-order intermodulation components appearing in the frequency ranges defined in Article 3.3.3. The width of the intermodulation components must be taken into account.

6) Ensure that the emission levels do not exceed the required limits, except for the interference signal frequencies.

7) Repeat the testing for the remaining central frequency offsets of the interference signals under the conditions of Table 24.

Additionally, the following steps apply for a multi-band capable BS:

8) For single-band tests and multi-band capable BSs, repeat the above steps for each relevant band where the single-band test setups and test models apply to carriers not active on other bands. For multi-band capable BSs with separate antenna ports, do not perform testing when the antenna ports are terminated.

NOTE: Third-order intermodulation components are (2F1 ± F2) and (F1 ± 2F2), fifth-order intermodulation components are (3F1 ± 2F2), (2F1 ± 3F2), (4F1 ± F2), and (F1 ± 4F2), where F1 corresponds to the desired signal center frequency or the center frequency of each component block, and F2 corresponds to the interference signal center frequency.

The width of the intermodulation components is:

(n x BWF1 + m x 5 MHz) for components nF1 ± mF2;

(n x 5 MHz + m x BWF1) for components mF1 ± nF2;

In this context, BWF1 corresponds to the desired RF signal bandwidth, or the channel bandwidth in the case of single-carrier waves, or the component block bandwidth.

3.3.8. Receiver Modulation Characteristics

3.3.6.1. Initial Conditions

Test environment: Normal; see Article B.1 of Appendix B.

The RF channels that need to be measured for single-carrier waves: M; see Article 3.1.

The RF bandwidth positions of the base station that need to be tested for multiple carriers:

- MRFBW at single-band operation; see Article 3.1.

- BRFBW_T'RFBW and B'RFBW_TRFBW at multi-band operation; see Clause 3.1.

Measurement Setup:

1) Connect the receiver measurement device to the antenna port of the BS as described in Article C.2.6 of Appendix C.

2) Activate the BS transmitter.

3) Terminate the BS transmission antenna port as specified in Article C.2.6 of Appendix C.

3.3.6.2. Measurement Procedure

1) For the FDD BS declared capable of operating only with single-carrier waves, start the BS transmission according to E-TM 1.1 in ETSI TS 136 141 at the rated output power Prated,c as published by the manufacturer.

For the FDD BS declared capable of operating with multi-carrier waves and/or carrier aggregation, configure the BS transmission according to E-TM1.1 on all configured carriers using the corresponding test settings and power levels as stipulated in Articles 4.10 and 4.11 of ETSI TS 136 141.

2) Set up the measurement equipment parameters as specified in Table 25.

3) Measure the spurious emissions over each frequency band as defined in Article 2.2.72.

4) Repeat the measurements for the (any) terminated RX ports.

Additionally, the following step applies to BSs capable of multi-carrier operation:

5) Với đo kiểm đơn băng tần và BS hoạt động đa băng tần, lặp lại các bước trên cho từng băng tần liên quan trong đó các thiết lập đo kiểm đơn băng tần và các mô hình đo kiểm áp dụng với sóng mang không hoạt động trong băng tần khác. Với BS có khả năng hoạt động đa băng tần có đầu nối ăng ten riêng biệt, không tiến hành đo kiểm trong trường hợp đầu nối ăng ten đơn sóng mang hoặc đa sóng mang được kết cuối.

3.3.7. Đặc tính chặn

3.3.7.1. Điều kiện ban đầu

Môi trường đo kiểm: Bình thường; xem điều B.1, Phụ lục B.

Các kênh RF cần được đo kiểm cho đơn sóng mang: B, M và T; xem điều 3.1.

Các vị trí băng thông RF trạm gốc cần được đo kiểm cho đa sóng mang:

- MRFBW; xem điều 3.1.

- BRFBW_T'RFBW and B'RFBW_TRFBW tại hoạt động đa băng tần; xem điều 3.1. Ngoài ra, trong hoạt động đa sóng mang:

- Với BRFBW_T'RFBW, có thể bỏ qua việc kiểm tra chặn ngoài băng trên băng tần hoạt động cao nhất.

- Với B'RFBW_TRFBW, có thể bỏ qua việc kiểm tra chặn ngoài băng trên băng tần hoạt động thấp nhất.

Thiết lập đo kiểm:

BS phải được định cấu hình để hoạt động càng gần với trung tâm băng tần hoạt động (xem Bảng 1) càng tốt.

Đo kiểm các băng thông kênh:

a) Trong dải tần số từ (FUL_low - 20) MHz đến (FUL_high + 20) MHz, các yêu cầu được đo kiểm với các băng thông thấp nhất và cao nhất được BS hỗ trợ.

b) Trong dải tần số từ 1 MHz đến (FUL_low - 20) MHz và (FUL_high + 20) MHz đến 12 750 MHz, các yêu cầu chỉ được đo kiểm với băng thông thấp nhất được BS hỗ trợ.

1) Đấu nối bộ tạo tín hiệu cho tín hiệu mong muốn và bộ tạo tín hiệu cho tín hiệu can nhiễu đến đầu nối ăng ten của một cổng như quy định trong điều C.2.5, Phụ lục C.

2) Kết cuối bất kỳ cổng RX nào khác không đo kiểm.

3) Khởi động phát theo kênh đo chuẩn được trình bày trong điều A.1 của ETSI TS 136 141 tới BS đo kiểm. Mức tín hiệu mong muốn được đo tại đầu nối ăng ten BS sẽ phải thiết lập đến mức quy định trong điều 2.2.8.2.

3.3.7.2. Thủ tục do

1) Với BS FDD chỉ có khả năng hoạt động sóng mang đơn, khởi động phát BS theo E-TM 1.1 của ETSI TS 136 141 tại công suất ra danh định Prated,c do nhà sản xuất công bố.

Với BS FDD khai báo có khả năng hoạt động đa sóng mang và/hoặc hoạt động CA, thiết lập BS phát theo E-TM1.1 trên tất cả các sóng mang được cấu hình bằng cách sử dụng các thiết lập cấu đo kiểm và công suất tương ứng theo quy định trong điều 4.10 và 4.11 của ETSI TS 136 141.

Máy phát có thể được tắt trong các đo kiểm khóa ngoài băng khi tần số của bộ khóa không có các sản phẩm IM2 hoặc IM3 bên trong băng thông tín hiệu mong muốn.

2) Điều chỉnh bộ tạo tín hiệu để tạo các tín hiệu can nhiễu, các mức và các độ lệch tần số theo quy định trong các Bảng 26, Bảng 27, Bảng 28 hoặc Bảng 29 và Bảng 30. Tín hiệu can nhiễu E-UTRA được quét với bước quét có kích thước 1 MHz, bắt đầu từ độ lệch cực tiểu đến các biên kênh của tín hiệu mong muốn theo quy định trong Bảng 29. Tín hiệu can nhiễu CW được quét với bước quét có kích thước 1 MHz trong dải tần theo quy định trong các Bảng 26, Bảng 27, Bảng 28 hoặc Bảng 30.

3) Đo thông lượng tín hiệu mong muốn tại máy thu BS theo quy định trong Phụ lục E của ETSI TS 136 141 cho hoạt động đa sóng mang, thông lượng này phải được đo cho các sóng mang liên quan được quy định trong thiết lập đo kiểm trong điều 4.10 của ETSI TS 136 141.

4) Hoán đổi các đấu nối của các cổng thu BS và lặp lại các phép đo từ bước 1) đến 3).

Ngoài ra, các bước sau áp dụng cho BS có khả năng hoạt động đa sóng mang với các đầu nối ăng ten riêng biệt:

5) Với đo kiểm đơn băng tần, lặp lại các bước trên cho từng băng tần liên quan trong đó các thiết lập đo kiểm đơn băng tần và các mô hình đo kiểm áp dụng với sóng mang không hoạt động trong băng tần khác.

6) Tín hiệu can nhiễu đầu tiên áp dụng trên cùng cổng như tín hiệu mong muốn. Đo kiểm lặp lại với các tín hiệu can nhiễu áo dụng trên cổng khác (nếu có) được ánh xạ đến cùng máy thu như tín hiệu mong muốn. Tiến hành đo kiểm trong trường hợp đầu nối ăng ten bất kỳ không có tín hiệu đơn sóng mang hoặc đa sóng mang được kết cuối.

7) Lặp lại bước 6) với tín hiệu mong muốn cho (các) băng tần khác áp dụng trong (các) cổng tương ứng.

3.3.8. Đặc tính xuyên điều chế máy thu

3.3.8.1. Điều kiện ban đầu

Môi trường đo kiểm: Bình thường: xem điều B.1, Phụ lục B.

Các kênh RF cần được đo kiểm cho đơn sóng mang: B, M và T; xem điều 3.1.

Các vị trí băng thông RF trạm gốc cần được đo kiểm cho đa sóng mang:

- BRFBW, MRFBW và TRFBW tại hoạt động đơn băng tần; xem điều 3.1.

- BRFBW_T'RFBW and B'RFBW_TRFBW tại hoạt động đa băng tần; xem điều 3.1.

Thiết lập đo kiểm:

1) Thiết lập các hệ thống đo kiểm như mô tả trong điều C.2.7, Phụ lục C.

3.3.8.2. Thủ tục đo

1) Tạo tín hiệu mong muốn bằng cách sử dụng cấu hình đo trong điều 4.10 và 4.11 của ETSI TS 136 141 và thiết lập mức tín hiệu đến BS đang đo kiểm ở mức được quy định trong Bảng 31.

2) Điều chỉnh các bộ tạo tín hiệu phát ra tín hiệu can nhiễu tại các mức và độ lệch tần số được quy định trong Bảng 31 và Bảng 32 cho yêu cầu xuyên điều chế, Bảng 33 cho yêu cầu xuyên điều chế băng hẹp BS diện rộng, Bảng 36 cho yêu cầu xuyên điều chế băng hẹp BS có vùng phục vụ trung bình,

3) Bảng 34 cho yêu cầu xuyên điều chế băng hẹp BS cục bộ và Bảng 35 cho yêu cầu xuyên điều chế băng hẹp BS trong nhà.

4) Đo thông lượng theo quy định trong Phụ lục E của ETSI TS 136 141, với hoạt động đa sóng mang, thông lượng đo được đối với các sóng mang liên quan phải tuân theo thủ tục đo kiểm trong điều 4.10 và 4.11 của ETSI TS 136 141.

5) Lặp lại toàn bộ đo kiểm cho (các) cổng đã được kết cuối.

Ngoài ra, các bước sau áp dụng cho BS có khả năng hoạt động đa sóng mang với các đầu nối ăng ten riêng biệt:

6) Với đo kiểm băng tần đơn, lặp lại các bước trên cho từng băng tần liên quan trong đó các thiết lập đo kiểm băng tần đơn áp dụng cho sóng mang không hoạt động trong băng tần khác.

7) Tín hiệu can nhiễu đầu tiên áp dụng trên cùng một cổng được coi như tín hiệu mong muốn. Đo kiểm lặp lại với các tín hiệu can nhiễu áp dụng trên cổng khác (nếu có) được ánh xạ đến cùng máy thu như tín hiệu mong muốn. Tiến hành đo kiểm trong trường hợp đầu nối ăng ten bất kỳ không có tín hiệu đơn sóng mang hoặc đa sóng mang được kết cuối.

8) Lặp lại bước 6) với tin hiệu mong muốn cho (các) băng tần khác áp dụng trong (các) cổng tương ứng.

3.3.9. Độ chọn lọc kênh lân cận (ACS) và chặn băng hẹp

3.3.9.1. Điều kiện ban đầu

Môi trường đo kiểm: Bình thường: xem điều B.1, Phụ lục B.

Các kênh RF cần được đo kiểm cho đơn sóng mang: B, M và T; xem điều 3.1.

Các vị trí băng thông RF trạm gốc cần được đo kiểm cho đa sóng mang:

- MRFBW tại hoạt động đơn băng tần; xem điều 3.1.

- BRFBW_T'RFBW and B'RFBW_TRFBW tại hoạt động đa băng tần; xem điều 3.1.

Thiết lập đo kiểm:

1) Thiết lập các hệ thống đo kiểm như mô tả trong điều C.2.4, Phụ lục C.

3.3.9.2. Thủ tục đo cho độ chọn lọc kênh lân cận

1) Tạo tín hiệu mong muốn bằng cách sử dụng cấu hình đo trong điều 4.10 và 4.11 của ETSI TS 136 141 và thiết lập mức tín hiệu đầu vào đến BS đang đo kiểm ở mức được quy định trong Bảng 39 cho BS diện rộng, trong Bảng 42 cho BS có vùng phục vụ trung bình, Bảng 40 cho BS cục bộ và Bảng 41 cho BS trong nhà.

2) Thiết lập tín hiệu can nhiễu tại tần số kênh lân cận và điều chỉnh mức tín hiệu can nhiễu tại đầu vào BS đến mức được quy định trong Bảng 39 cho BS diện rộng, Bảng 42 cho BS có vùng phục vụ trung bình, Bảng 40 cho BS cục bộ và Bảng 41 cho BS trong nhà.

3) Đo thông lượng theo quy định trong Phụ lục E của ETSI TS 136 141, với hoạt động đa sóng mang, thông lượng đo được đối với các sóng mang liên quan phải tuân theo thủ tục đo kiểm trong điều 4.10 và 4.11 của ETSI TS 136 141.

4) Lặp lại toàn bộ đo kiểm cho (các) cổng đã được kết cuối.

Ngoài ra, các bước sau áp dụng cho BS có khả năng hoạt động đa sóng mang với các đầu nối ăng ten riêng biệt:

5) Với đo kiểm băng tần đơn, lặp lại các bước trên cho từng băng tần liên quan trong đó các thiết lập đo kiểm băng tần đơn áp dụng cho sóng mang không hoạt động trong băng tần khác.

6) Tín hiệu can nhiễu đầu tiên áp dụng trên cùng một cổng được coi như tín hiệu mong muốn. Đo kiểm lặp lại với các tín hiệu can nhiễu áp dụng trên cổng khác (nếu có) được ánh xạ đến cùng máy thu như tín hiệu mong muốn. Tiến hành đo kiểm trong trường hợp đầu nối ăng ten bất kỳ không có tín hiệu đơn sóng mang hoặc đa sóng mang được kết cuối.

7) Lặp lại bước 6) với tín hiệu mong muốn cho (các) băng tần khác áp dụng trong (các) cổng tương ứng.

3.3.9.3. Thủ tục đo cho chặn băng hẹp

1) Với BS FDD chỉ có khả năng hoạt động sóng mang đơn, khởi động phát BS theo E-TM 1.1 của ETSI TS 136 141 tại công suất ra danh định do nhà sản xuất công bố.

Với BS FDD khai báo có khả năng hoạt động đa sóng mang, thiết lập BS phát theo E-TM1.1 trên tất cả các sóng mang được cấu hình bằng cách sử dụng các thiết lập đo kiểm và công suất tương ứng theo quy định trong điều 4.10 và 4.11 của ETSITS 136 141.

2) Tạo tín hiệu mong muốn bằng cách sử dụng cấu hình đo trong điều 4.10 và 4.11 của ETSI TS 136 141 và thiết lập mức tín hiệu đến BS đang đo kiểm tại mức được quy định trong Bảng 37.

3) Điều chỉnh mức tín hiệu mong muốn tại đầu vào BS ở mức tín hiệu được quy định trong Bảng 37. Thiết lập và điều chỉnh độ lệch tần số trung tâm RB can nhiễu tới biên kênh của tín hiệu mong muốn quy định trong Bảng 38.

4) Đo thông lượng theo quy định trong Phụ lục E của ETSI TS 136 141, với hoạt động đa sống mang, thông lượng đo được đối với các sóng mang liên quan phải tuân theo thủ tục đo kiểm trong điều 4.11 của ETSI TS 136 141.

5) Lặp lại toàn bộ đo kiểm cho (các) cổng đã được kết cuối.

Ngoài ra, các bước sau áp dụng cho BS có khả năng hoạt động đa sóng mang với các đầu nối ăng ten riêng biệt:

6) Với đo kiểm băng tần đơn, lặp lại các bước trên cho từng băng tần liên quan trong đó các thiết lập đo kiểm băng tần đơn áp dụng cho sóng mang không hoạt động trong băng tần khác.

7) Tín hiệu can nhiễu đầu tiên áp dụng trên cùng một cổng được coi như tín hiệu mong muốn. Đo kiểm lặp lại với các tín hiệu can nhiễu áp dụng trong cổng khác (nếu có) được ánh xạ đến cùng máy thu như tín hiệu mong muốn. Tiến hành đo kiểm trong trường hợp đầu nối ăng ten bất kỳ không có tín hiệu đơn sóng mang hoặc đa sóng mang được kết cuối.

8) Lặp lại bước 6) với tín hiệu mong muốn cho (các) băng tần khác áp dụng trong (các) cổng tương ứng.

3.3.10. Công suất ra của trạm gốc trong nhà để bảo vệ kênh UTRA lân cận

3.3.10.1. Điều kiện ban đầu

Môi trường đo kiểm: Bình thường; xem điều B.1, Phụ lục B.

Các kênh RF cần được đo kiểm cho đơn sóng mang: M; xem điều 3.1;

Thiết lập đo kiểm:

1) Thiết lập thiết bị như mô tả trong điều C.1.4, Phụ lục C.

2) Cấu hình BS trong nhà phải thỏa mãn rằng các kênh lân cận khai báo giống khai báo của các nhà khai thác khác.

3.3.10.2. Thủ tục đo

1) Đấu nối các tín hiệu can nhiễu đường xuống được phối hợp (được xem như điểm D trong Hình C.4 Phụ lục C) tới cổng đo dành riêng (được xem như điểm 1 trong Hình C.4 Phụ lục C) trong trường hợp khả dụng, nếu không đấu nối tới điểm 2.

2) Cấu hình bộ tạo tín hiệu can nhiễu đồng kênh phát AWGN trên băng thông theo BWconfig được đặt giữa RF kênh M.

3) Cấu hình bộ tạo tín hiệu cho tín hiệu kênh lân cận DL để phát tín hiệu theo mô hình đo kiểm 1 trong ETSI TS 125 141 tại tần số trung tâm bằng RF kênh M + BWChannel/2 + 2,5 MHz.

4) Bật các bộ tạo tín hiệu phát các can nhiễu đồng kênh và can nhiễu kênh lân cận, và điều chỉnh ATT1 và ATT2 đến mức CPICH Êc = -80 dBm và loh = -50 dBm.

5) Kích thích cơ chế điều chỉnh công suất của trạm gốc trong nhà.

6) Cấu hình BS trong nhà để phát tín hiệu theo E-TM1.1 trong ETSI TS 136 141. Tín hiệu phải được phát với công suất ra cực đại cho phép.

7) Đo công suất ra của BS trong nhà, Pout, và kiểm tra công suất này có nhỏ hơn giá trị đã quy định theo các giá trị của CPICH Êc và loh được xác định trong bước 4).

8) Lặp lại các bước từ 3) đến 7) với tần số trong bước 3) được thiết lập ở RF kênh M - BWChannel -2,5 MHz.

9) Lặp lại các bước từ 3) đến 8) với các thiết lập khác nhau cho ATT1 và ATT2 để đạt được các cặp CPICH Êc và loh như quy định trong Bảng 52.

Bảng 52 - Thiết lập các tham số đo kiểm

Trường hợp đo kiểmCRS Ês (dBm)loh (dBm)2-90-603-100-704-100-50

3.3.11. Công suất ra của trạm gốc trong nhà để bảo vệ kênh E-UTRA lân cận

3.3.11.1. Điều kiện ban đầu

Môi trường đo kiểm: Bình thường; xem điều B.1, Phụ lục B.

Các kênh RF cần được đo kiểm cho đơn sóng mang: M; xem điều 3.1.

Ngoài ra, chỉ trên một kênh EARFCN, đo kiểm phải được thực hiện trong điều kiện nguồn cung cấp tới hạn quy định trong điều B.4, Phụ lục B.

CHÚ THÍCH: Các đo kiểm trong điều kiện nguồn cung cấp tới hạn cũng được thực hiện trong điều kiện nhiệt độ tới hạn, xem điều B.2, Phụ lục B.

Tắt các bộ tạo tín hiệu phát ra các can nhiễu đồng kênh và can nhiễu kênh lân cận.

Thiết lập đo kiểm:

1) Thiết lập thiết bị như mô tả trong điều C.1.4, Phụ lục C.

2) Cấu hình BS trong nhà phải thỏa mãn rằng các kênh lân cận được khai báo giống như khai báo của các nhà khai thác khác.

3.3.11.2. Thủ tục đo

1) Đấu nối các tín hiệu can nhiễu đường xuống sau khi trộn (được xem như điểm D trong Hình C.4 của Phụ lục C) tới cổng đo dành riêng (được xem như điểm 1 trong Hình C.4 của Phụ lục C) trong trường hợp khả thi, nếu không đấu nối tới điểm 2.

2) Cấu hình bộ tạo tín hiệu can nhiễu đồng kênh phát AWGN trên băng thông theo BWConfig được đặt giữa RF kênh M.

3) Cấu hình bộ tạo tín hiệu cho tín hiệu DL kênh lân cận để phát tín hiệu theo E- TM1.1 trong ETSI TS 136 141 tại tần số trung tâm băng RF kênh M + BWChannel MHz.

4) Bật các bộ tạo tín hiệu phát các nhiễu đồng kênh và nhiễu kênh lân cận, và điều chỉnh ATT1 và ATT2 đến mức CRS Ês = -65 - 10 · log10 () dBm và loh = -50 dBm.

5) Kích thích cơ chế điều chỉnh công suất của trạm gốc trong nhà.

6) Cấu hình BS trong nhà để phát tín hiệu theo E-TM1.1 trong ETSI TS 136 141. Tín hiệu phải được phát với công suất ra cực đại cho phép.

7) Đo công suất ra của BS trong nhà, Pout, và kiểm tra xem công suất này có nhỏ hơn giá trị đã quy định theo các giá trị của CRS Ês và loh được xác định trong bước 4).

8) Lặp lại các bước từ 3) đến 7) với tần số trong bước 3) được thiết lập ở kênh M của RF - BWChannel MHz.

9) Lặp lại các bước từ 3) đến 8) với các thiết lập khác nhau cho ATT 1 và ATT2 để đạt được các cặp CRS Ês và loh như quy định trong Bảng 53.

Bảng 53 - Các cặp CRS Ês và loh

Trường hợp đo kiểmCRS Ês (dBm)loh (dBm)

2

- 75 - 10 · log10 ()

-60
3

- 90 - 10 · log10()

-70
4

- 90 - 10 · log10 ()

-50

3.3.12. Công suất ra của trạm gốc trong nhà để bảo vệ E-UTRA đồng kênh

3.3.12.1. Điều kiện ban đầu

Môi trường đo kiểm: Bình thường: xem điều B.1, Phụ lục B.

Các kênh RF cần được đo kiểm cho đơn sóng mang: M; xem điều 3.1.

Ngoài ra, chỉ trên một kênh EARFCN, đo kiểm phải được thực hiện trong điều kiện nguồn cung cấp tới hạn quy định trong điều B.4, Phụ lục B.

CHÚ THÍCH: Các đo kiểm trong điều kiện nguồn cung cấp tới hạn cũng được thực hiện trong điều kiện nhiệt độ tới hạn, xem điều B.2, Phụ lục B.

Tắt các bộ tạo tín hiệu phát ra các can nhiễu đồng kênh và can nhiễu kênh lân cận.

Thiết lập đo kiểm:

1) Thiết lập thiết bị như mô tả trong điều C.1.5, Phụ lục C dựa trên tùy chọn được BS trong nhà hỗ trợ.

2) Can nhiễu đồng kênh được cấu hình chứa ít nhất một tín hiệu của BS marco ngay cạnh. Đối với tùy chọn 2 trong Bảng 45, bộ tạo tín hiệu bổ sung cần cung cấp tín hiệu UL MUE.

3.3.12.2. Thủ tục đo

1) Đấu nối các tín hiệu can nhiễu đường xuống sau khi trộn (được xem như điểm D trong Hình C.5 Phụ lục C) tới cổng đo dành riêng (được xem như điểm 1 trong Hình C.5 Phụ lục C) trong trường hợp khả thi, nếu không đấu nối tới điểm 2. Riêng với tùy chọn 2 trong Bảng 45, đấu nối can nhiễu UL tới điểm 2 cho UL thu như trong Hình C.6.

2) Cấu hình bộ tạo tín hiệu can nhiễu đồng kênh phát AWGN trên băng thông theo BWConfig được đặt giữa RF kênh M.

3) Cấu hình X = 30 dB. Bật các bộ tạo tín hiệu phát các can nhiễu, và điều chỉnh ATT đến mức CRS Ês = -10 - 10 · log10 () dBm và loh = -50 dBm.

4) Kích thích cơ chế điều chỉnh công suất của trạm gốc trong nhà.

5) Cấu hình BS trong nhà để phát tín hiệu theo E-TM1.1 trong ETSI TS 136 141. Tín hiệu phải được phát với công suất ra cực đại cho phép.

6) Đo công suất ra của BS trong nhà, Pout, và kiểm tra xem công suất này có nhỏ hơn giá trị đã quy định theo các giá trị của CRS Ês và loh được xác định trong bước 3). Giá trị Pmin cho đo kiểm là -10 dBm.

7) Lặp lại các bước từ 4) đến 6) với các thiết lập khác nhau cho ATT để đạt được các cặp CRS Ês và loh như quy định trong Bảng 54 hoặc Bảng 55, cho tùy chọn trong Bảng 45.

Bảng 54 - Các CRS Êc và Eoh cho tùy chọn 1

Trường hợp đo kiểmCRS Ês (dBm)loh (dBm)

1

-20 -10 · log10()

-60
2

Pmin -30-10 · log10 ()

-70
3

-90-10 · log10 ()

-50

Bảng 55 - Các CRS Êc và loh cho tùy chọn 2

Trường hợp đo kiểmCRS Ês (dBm)loh (dBm)lob (dBm)

1

-75 -10 · log10()

-60 -98
2

Pmin - 30 -10 · log10()

-70 -98
3

-90 -10 · log10 ()

-50 -98

3.3.13. Mức chọn lọc chuẩn

3.3.13.1. Điều kiện ban đầu

Môi trường đo kiểm: Bình thường; xem điều B.1, Phụ lục B.

Các kênh RF cần được đo kiểm cho đơn sóng mang: B, M và T; xem điều 3.1.

Các vị trí đo bổ sung được thiết lập như sau:

a) Trên từng điểm B, M và T, đo kiểm phải thực hiện trong điều kiện nguồn cung cấp tới hạn quy định trong điều B.4, Phụ lục B.

CHÚ THÍCH: Các đo kiểm trong điều kiện nguồn cung cấp tới hạn cũng được thực hiện trong điều kiện nhiệt độ tới hạn, xem điều B.2, Phụ lục B.

Thiết lập đo kiểm:

1) Kết nối thiết bị đo như mô tả trong điều C.2.1, Phụ lục C.

3.3.13.2. Thủ tục đo

1) Với BS FDD, khởi động phát BS theo E-TM 1.1 trong ETSI TS 136 141 tại công suất ra danh định Prated,c do nhà sản xuất công bố.

2) Thiết lập công suất trung bình tín hiệu đo được quy định trong Bảng 46 cho BS diện rộng, Bảng 47 cho BS cục bộ, Bảng 48 cho BS trong nhà và Bảng 49 cho BS có vùng phục vụ trung bình.

3) Đo thông lượng theo phụ lục E trong ETSI 136 141.

4) Lặp lại bước đo cho (các) cổng RX khác.

Ngoài ra, các bước sau áp dụng cho BS có khả năng hoạt động đa sóng mang:

5) Với đo kiểm băng tần đơn và BS có khả năng hoạt động đa sóng mang, lặp lại các bước trên cho từng băng tần liên quan trong đó các thiết lập đo kiểm đơn băng tần áp dụng với sóng mang không hoạt động trong băng tần khác. Không tiến hành đo kiểm đầu nối băng ten được kết cuối với BS đa sóng mang có đầu nối ăng ten riêng biệt.

3.3.14. Phát xạ bức xạ

3.3.14.1. Phương pháp đo

1) Vị trí đo kiểm phải đáp ứng hoàn toàn các yêu cầu Khuyến nghị ITU-R SM.329-12. Thiết bị cần đo kiểm EUT được đặt trên một giá đỡ không dẫn điện và được cấp nguồn qua bộ lọc RF để hạn chế bức xạ từ các dây dẫn điện.

Công suất trung bình của bất kỳ thành phần phát xạ nào cũng phải được phát hiện bởi ăng ten đo kiểm và máy thu đo (ví dụ một máy phân tích phổ). Tại mỗi một tần số của phát xạ được phát hiện và công suất bức xạ hiệu dụng (E.R.P) của thành phần phát xạ đó được xác định bằng một phép đo thay thế, điều chỉnh độ cao của ăng ten đo kiểm và quay EUT để thu được đáp ứng tối đa. Phép đo phải được lặp lại với ăng ten đo kiểm trong mặt phẳng phân cực trực giao.

CHÚ THÍCH: Công suất bức xạ hiệu dụng (E.R.P) là bức xạ của một nửa sóng đã được điều chỉnh bởi ăng ten lưỡng cực thay vì ăng ten đẳng hướng. Hệ số chuyển đổi giữa e.i.r.p và E.R.P. là 2,15 dB

E R.P (dBm) = e.i.r.p. (dBm) -2,15

(Khuyến nghị SM.329-12, Phụ lục 1 của ITU-R).

2) BS phải phát với công suất tối đa theo công bố của nhà sản xuất với tất cả máy phát hoạt động. Thiết lập trạm gốc để phát một tín hiệu như đã quy định trong phần đo các phát xạ giả.

Trong trường hợp có bộ lặp, độ tăng ích và công suất ra phải được điều chỉnh đến giá trị tối đa như đã được nhà sản xuất công bố. Sử dụng tín hiệu ngõ vào như đã quy định trong phần đo các phát xạ giả.

3) Độ rộng băng video phải gần bằng ba lần độ rộng băng phân giải. Nếu độ rộng băng video này không khả dụng trên máy thu đo thì độ rộng này phải được điều chỉnh tối đa có thể và tối thiểu phải bằng 1 MHz. Ngoại trừ trường hợp đặc biệt, tất cả các phép đo phải đo kiểm với công xuất trung bình. Công suất thu được sẽ được đo trên các dải tần số và sử dụng băng thông đo kiểm quy định trong Bảng 50.

3.3.14.2. Cấu hình đo

Điều này xác định các cấu hình để đo kiểm phát xạ như sau:

- Thiết bị phải được đo kiểm trong các điều kiện đo kiểm bình thường theo quy định;

- Cấu hình đo kiểm càng gần với cấu hình sử dụng thông thường càng tốt;

- Nếu thiết bị là một phần của hệ thống hoặc được kết nối hệ thống qua thiết bị phụ, thì có thể đo kiểm thiết bị khi kết nối với cấu hình tối thiểu của thiết bị phụ cần thiết để thử các cổng;

- Nếu thiết bị có nhiều cổng, phải lựa chọn đủ số cổng để mô phỏng các điều kiện hoạt động thực và bảo đảm rằng tất cả các kết cuối khác nhau đều được đo kiểm;

- Các điều kiện đo kiểm, các cấu hình đo kiểm và chế độ hoạt động phải được ghi lại trong báo cáo đo kiểm;

- Các cổng hoạt động bình thường được kết nối với một thiết bị phụ hoặc một đoạn cáp để mô phỏng các đặc tính vào/ra của thiết bị phụ, các cổng vào/ra tần số vô tuyến (RF) được kết cuối chính xác;

- Đối với các cổng hoạt động bình thường không kết nối với cáp, ví dụ các đầu nối dịch vụ, các đầu nối lập trình, các đầu nối tạm thời. Các cổng này phải không được kết nối với bất cứ cáp nào cho Điều đích đo kiểm. Khi có cáp kết nối tới những cổng này hoặc các cáp liên kết bắt buộc phải mở rộng chiều dài để đo kiểm EUT thì phải đảm bảo việc đo kiểm đánh giá EUT không bị ảnh hưởng bởi việc bổ sung hay kéo dài các cáp này.

Đối với một EUT chứa nhiều BS, chỉ cần thực hiện đo kiểm đối với các đầu nối của BS điển hình của EUT.

Đối với EUT có nhiều trạm lặp, chỉ cần thực hiện đo kiểm đối với các đầu nối của trạm lặp điển hình của EUT.

Tùy theo nhà sản xuất, đo kiểm có thể được thực hiện trên thiết bị phụ riêng rẽ hoặc trên một cấu hình điển hình của một tổ hợp thiết bị vô tuyến và thiết bị phụ. Trong mỗi trường hợp, EUT được đo kiểm theo các quy định về phát xạ của Quy chuẩn này và cho phép thiết bị phụ được sử dụng với các thiết bị vô tuyến khác.

4. QUY ĐỊNH VỀ QUẢN LÝ

Các thiết bị vô tuyến liên quan thuộc phạm vi điều chỉnh quy định tại điều 1.1 phải tuân thủ các quy định kỹ thuật trong Quy chuẩn này.

5. TRÁCH NHIỆM CỦA TỔ CHỨC, CÁ NHÂN

Các tổ chức, cá nhân liên quan có trách nhiệm thực hiện các quy định về chứng nhận và công bố hợp quy các thiết bị thuộc phạm vi của Quy chuẩn này và chịu sự kiểm tra của cơ quan quản lý nhà nước theo các quy định hiện hành.

6. TỔ CHỨC THỰC HIỆN

6.1. Cục Viễn thông, Cục Tần số vô tuyến điện, các Sở Thông tin và Truyền thông có trách nhiệm tổ chức hướng dẫn triển khai quản lý các thiết bị vô tuyến theo Quy chuẩn này.

6.2. Trong trường hợp các quy định nêu tại Quy chuẩn này có sự thay đổi, bổ sung hoặc được thay thế thì thực hiện theo quy định tại văn bản mới.

6.3. Trong quá trình triển khai thực hiện quy chuẩn này, nếu có vấn đề phát sinh, vướng mắc, các tổ chức và cá nhân có liên quan phản ánh bằng văn bản về Bộ Thông tin và Truyền thông (Vụ Khoa học và Công nghệ) để được hướng dẫn, giải quyết./.

 

PHỤ LỤC A

(Quy định)

Cấu hình trạm gốc

A.1. Thu tín hiệu với nhiều đầu nối ăng ten máy thu, phân tập máy thu

Với các đo kiểm trong điều 3, yêu cầu phải áp dụng tại từng đầu nối ăng ten máy thu cho các máy thu với phân tập ăng ten hoặc trong trường hợp thu đa sóng mang với nhiều đầu nối ăng ten máy thu.

Các yêu cầu máy thu được đo tại đầu nối ăng ten với các máy thu còn lại bị vô hiệu hóa hoặc kết cuối các đầu nối ăng ten của nó. Nếu nhà sản xuất công bố theo cách máy thu tương đương, có đủ khả năng áp dụng các quy định tín hiệu đo tại một đầu nối ăng ten máy thu bất kỳ.

Với BS đa sóng mang, các đo kiểm đa sóng mang cho chặn và xuyên điều chế được thực hiện với nhiều can nhiễu áp dụng cho từng đầu nối ăng ten ánh xạ đến máy thu cho các tín hiệu mong muốn, tuy nhiên chỉ với duy nhất một ăng ten tại một thời điểm. Kết cuối áp dụng với các đầu nối ăng ten không có tín hiệu.

A.2. Các bộ song công

Những yêu cầu của quy chuẩn này phải được đáp ứng với một bộ song công thích hợp, nếu bộ song công được cung cấp như một phần của BS. Nếu bộ song công được nhà sản xuất cung cấp như một tùy chọn, thì những đo kiểm đầy đủ phải được lặp lại trong trường hợp có và không có bộ song công thích hợp để xác định xem BS có đáp ứng các yêu cầu của Quy chuẩn này trong cả hai trường hợp hay không.

Những đo kiểm sau đây phải được thực hiện với bộ song công thích hợp, và không có bộ song công thích hợp nếu bộ song công này là tùy chọn:

1) Điều 3.3.4, công suất ra cực đại của trạm gốc, chỉ đối với mức công suất tĩnh cao nhất, nếu đo tại đầu nối ăng ten;

2) Điều 3.3.3, các phát xạ phổ của máy phát; bên ngoài băng phát của BS;

3) Điều 3.3.5, xuyên điều chế máy phát; để đo kiểm hợp quy, các tần số sóng mang phải được lựa chọn để giảm thiểu các thành phần xuyên điều chế từ các máy phát rơi vào các kênh thu.

Những đo kiểm còn lại có thể được thực hiện trong trường hợp có hoặc không có bộ song công thích hợp.

CHÚ THÍCH 1: Khi thực hiện đo kiểm máy thu với một bộ song công thích hợp, điều quan trọng là phải bảo đảm sao cho đầu ra từ các máy phát không ảnh hưởng đến thiết bị đo kiểm. Có thể sử dụng một tổ hợp các bộ suy hao, các bộ cách ly và các bộ lọc để đạt được việc này.

CHÚ THÍCH 2: Khi sử dụng các bộ song công, các thành phần xuyên điều chế được tạo ra, không chỉ ở trong bộ song công mà còn ở trong hệ thống ăng ten. Các thành phần xuyên điều chế được tạo ra trong hệ thống ăng ten không được điều chỉnh theo các yêu cầu kỹ thuật, và có thể suy giảm trong thời gian hoạt động (ví dụ: do sự thâm nhập của hơi nước). Vì vậy, để bảo đảm cho hoạt động liên tục thỏa đáng của một BS, thông thường nhà khai thác sẽ lựa chọn các UARFCN để giảm thiểu các thành phần xuyên điều chế rơi vào các kênh thu. Nhà khai thác có thể chỉ định các UARFCN cần dùng để đo kiểm toàn diện.

A.3. Các tùy chọn nguồn cung cấp

Nếu BS được cung cấp với một số cấu hình nguồn cung cấp khác nhau, có thể không cần đo kiểm các tham số RF đối với từng tùy chọn của nguồn cung cấp điện nếu chứng minh được rằng phạm vi các điều kiện mà thiết bị được đo kiểm ít ra cũng lớn bằng phạm vi các điều kiện đặt ra cho bất cứ cấu hình nguồn cung cấp nào.

Điều này được đặc biệt áp dụng nếu một BS có một thanh DC có thể được cấp nguồn từ bên ngoài hoặc từ một nguồn cung cấp của mạng điện nội bộ. Trong trường hợp này, những điều kiện về nguồn cung cấp điện tới hạn đối với các tùy chọn của nguồn cung cấp của mạng điện có thể được đo kiểm bằng cách chỉ đo kiểm tùy chọn của nguồn cung cấp DC bên ngoài. Dải điện áp vào DC để đo kiểm phải đủ để xác định chỉ tiêu đối với bất cứ nguồn cung cấp điện nào trong các nguồn cung cấp điện, trong phạm vi điều kiện hoạt động của BS, kể cả sự thay đổi của điện áp vào của mạng điện, nhiệt độ và dòng ra.

A.4. Các bộ khuếch đại RF phụ

Các yêu cầu của quy chuẩn này phải được đáp ứng với bộ khuếch đại RF phụ thích hợp. Với những đo kiểm theo điều 3 cho TX và RX tương ứng, bộ khuếch đại phụ được nối với BS qua một mạng kết nối (bao gồm bất cứ (các) cáp, (các) bộ suy hao nào...) với suy hao phù hợp để bảo đảm những điều kiện hoạt động thích hợp của bộ khuếch đại phụ và BS. Dải suy hao thích hợp của mạng kết nối được nhà sản xuất công bố. Những đặc tính khác và sự phụ thuộc nhiệt độ của độ suy hao của mạng kết nối được bỏ qua. Giá trị suy hao thực của mạng nối được chọn cho từng đo kiểm là một trong số các giá trị tới hạn được áp dụng. Giá trị thấp nhất được sử dụng nếu không có quy định khác.

Những đo kiểm thích đáng phải được lặp lại với bộ khuếch đại phụ thích hợp và không có bộ khuếch đại RF phụ, nếu bộ khuếch đại RF phụ đó là tùy chọn, để kiểm tra xem BS đáp ứng những yêu cầu của quy chuẩn trong cả hai trường hợp hay không.

Khi đo kiểm, những đo kiểm trong Bảng A.1 dưới đây phải được lặp lại với bộ khuếch đại phụ tùy chọn thích hợp, trong đó X chỉ ra rằng đo kiểm là thích hợp:

Bảng A.1 - Các đo kiểm áp dụng cho các bộ khuếch đại RF phụ

 ĐiềuChỉ cho bộ khuếch đại TXChỉ cho bộ khuếch đại TXCho các bộ khuếch đại TX/RX kết hợp (xem chú thích)Các đo kiểm máy thu3.3.9 XX3.3.7 XX3.3.6 XX3.3.8 X 3.3.13 XXCác đo kiểm máy phát3.3.1X X3.3.2X X3.3.3X X3.3.4X X3.3.5X XCHÚ THÍCH: Việc kết hợp có thể do các bộ lọc song công hoặc bất cứ mạng nào khác. Các bộ khuếch đại có thể ở trong nhánh RX hoặc ở trong nhánh TX hoặc trong cả hai nhánh. Một trong hai bộ khuếch đại này có thể là một mạng thụ động.

Trong đo kiểm tại điều 3.3.4, giá trị suy hao phù hợp lớn nhất được áp dụng.

A.5. BS sử dụng các giàn ăng ten

Một BS có thể được cấu hình với một kết nối đa cổng ăng ten cho một số hoặc tất cả các máy thu phát của nó; hoặc một BS có thể được cấu hình với một giàn ăng ten liên quan đến một cell (không phải một giàn cho từng máy thu phát). Điều này áp dụng cho một BS đáp ứng được ít nhất một trong các điều kiện sau đây;

- Các tín hiệu ra của máy phát từ một hoặc nhiều máy thu phát xuất hiện tại nhiều cổng ăng ten; hoặc

- Có nhiều cổng ăng ten của máy thu cho một máy thu phát hoặc cho từng cell và một tín hiệu vào được yêu cầu tại nhiều cổng để máy thu hoạt động đúng, do vậy các đầu ra từ các máy phát cũng như các đầu vào các máy thu được kết nối trực tiếp với vài ăng ten; hoặc

CHÚ THÍCH: Thu phân tập không bất buộc đáp ứng yêu cầu này.

- Các máy phát và các máy thu được kết nối qua các bộ song công tới nhiều ăng ten.

Trong hoạt động bình thường, nếu một BS được sử dụng cùng với một hệ thống ăng ten chứa các bộ lọc hoặc các phần từ tích cực cần thiết để đáp ứng các yêu cầu của UTRA, đo kiểm có thể được thực hiện trên một hệ thống bao gồm BS cùng với các phần tử này, được cung cấp riêng cho điều đích đo kiểm. Trong trường hợp này, phải chứng minh rằng chỉ tiêu của cấu hình đang được đo kiểm là điển hình cho hệ thống trong hoạt động bình thường và việc đánh giá hợp quy chỉ có thể áp dụng khi dùng BS với hệ thống ăng ten.

Để đo kiểm hợp quy một BS như vậy, các thủ tục sau đây có thể được sử dụng.

A.5.1. Đo kiểm máy thu

Đối với từng đo kiểm, các tín hiệu đo kiểm được đưa tới các đầu nối ăng ten của máy thu phải đủ lớn sao cho tổng các công suất của các tín hiệu đưa vào bằng công suất của (các) tín hiệu đo kiểm được chỉ ra trong đo kiểm.

Ví dụ về một cấu hình đo kiểm thích hợp như trong Hình A.1.

Hình A.1 - Thiết lập đo kiểm máy thu

Đối với các phát xạ giả từ đầu nối ăng ten của máy thu, có thể thực hiện đo kiểm riêng biệt cho từng đầu nối ăng ten của máy thu.

A.5.2. Đo kiểm máy phát

Đối với từng đo kiểm, các tín hiệu đo kiểm được đưa tới các đầu nối ăng ten của máy phát (Pi) phải đủ lớn sao cho tổng các công suất của các tín hiệu đưa vào bằng công suất của (các) tín hiệu đo kiểm (Ps) được chỉ ra trong đo kiểm. Có thể đánh giá việc này bằng cách đo riêng các tín hiệu được phát xạ bởi từng đầu nối ăng ten và cộng các kết quả lại, hoặc bằng cách kết hợp các tín hiệu và thực hiện một phép đo đơn. Các đặc tính (ví dụ biên độ và pha) của mạng kết hợp phải lớn đến mức công suất của tín hiệu kết hợp là tối đa.

Ví dụ về một cấu hình đo kiểm thích hợp như trong Hình A.2.

Hình A.2 - Thiết lập đo kiểm máy phát

Đối với suy hao xuyên điều chế, có thể thực hiện đo kiểm riêng biệt cho từng đầu nối ăng ten của máy phát.

A.6. Phát với nhiều đầu nối ăng ten máy phát

Với các đo kiểm trong điều 3, yêu cầu áp dụng cho từng đầu nối ăng ten máy phát trong trường hợp phát cho nhiều đầu nối ăng ten máy phát, trừ khi có quy định khác.

Các yêu cầu của máy phát được đo kiểm tại đầu nối ăng ten, với (các) đầu nối ăng ten còn lại đã được kết cuối. Nếu nhà sản xuất công bố theo cách máy phát tương đương, nó có khả năng đo tín hiệu tại một đầu nối ăng ten máy phát bất kỳ.

A.7. BS với môdem BS luant tích hợp

Đối với các đo kiểm trong quy chuẩn này, modem BS luant tích hợp sẽ bị tắt. Các phát xạ giả theo quy định trong các điều 3.3.3 và 3.3.6 chỉ đo tại các tần số lớn hơn 20 MHz với modem BS luat tích hợp được bật, trừ khi có quy định khác.

 

PHỤ LỤC B

(Tham khảo)

Điều kiện môi trường

Điều này xác định các điều kiện môi trường cho từng phép đo kiểm BS.

Các điều kiện môi trường sau đây có thể được nhà cung cấp khai báo:

- Áp suất khí quyển: thấp nhất và cao nhất;

- Nhiệt độ: thấp nhất và cao nhất;

- Độ ẩm tương đối: thấp nhất và cao nhất;

- Nguồn điện: giới hạn điện áp trên và dưới.

Khi hoạt động bên ngoài các giới hạn biên của điều kiện môi trường hoạt động đã khai báo, thiết bị này không được ảnh hưởng đến việc sử dụng hiệu quả phổ tần và gây ra nhiễu có hại.

B.1. Môi trường đo kiểm bình thường

Khi môi trường đo kiểm bình thường được chỉ định cho một đo kiểm, đo kiểm phải thực hiện trong các giới hạn thấp nhất và cao nhất của các điều kiện được chỉ định trong Bảng B.1.

Bảng B.1 - Giới hạn các điều kiện cho môi trường đo kiểm

Điều kiệnThấp nhấtCao nhấtÁp suất khí quyển86 kPa106 kPaNhiệt độ15°C30°CĐộ ẩm tương đối20%85%Nguồn điệnDanh định, như khai bảo của nhà sản xuấtĐộ rungKhông đáng kể

Các dải áp suất khí quyển, nhiệt độ và độ ẩm trên đây tương ứng với sự biến thiên tối đa được mong đợi trong môi trường không bị kiểm soát của một phòng thử nghiệm. Nếu không thể duy trì các tham số này trong phạm vi các giới hạn đã chỉ định, các giá trị thực tế phải được ghi lại trong báo cáo đo kiểm.

CHÚ THÍCH: Ví dụ, các phép đo phát xạ bức xạ trong một điểm đo kiểm trường mở rộng.

B.2. Môi trường đo kiểm tới hạn

Nhà sản xuất phải khai báo một trong những trường hợp sau:

1) Loại thiết bị đại diện cho thiết bị đang được đo kiểm, như được định nghĩa trong IEC 60721-3-3.

2) Loại thiết bị đại diện cho thiết bị đang được đo kiểm, như được định nghĩa trong IEC 60721-3-4.

3) Đối với thiết bị không tuân theo các loại đã được đề cập đến, các loại có liên quan trong tài liệu của IEC 60721 về nhiệt độ, độ ẩm và độ rung, phải được khai báo.

CHÚ THÍCH: Sự suy giảm tính năng do các điều kiện môi trường nằm ngoài các điều kiện hoạt động chuẩn không được đo kiểm trong quy chuẩn này. Những điều kiện môi trường này có thể được quy định và đo kiểm riêng.

B.2.1. Nhiệt độ tới hạn

Khi một môi trường đo kiểm nhiệt độ tới hạn được chỉ định cho một đo kiểm, đo kiểm phải được thực hiện với các nhiệt độ hoạt động thấp nhất và cao nhất chuẩn được xác định theo khai báo của nhà sản xuất cho thiết bị đang được đo kiểm.

Nhiệt độ thấp nhất:

Đo kiểm phải được thực hiện với thiết bị và các phương pháp đo kiểm môi trường gồm cả các hiện tượng môi trường yêu cầu tác động vào thiết bị, tuân theo thủ tục đo kiểm của IEC 60 068-2-1.

Nhiệt độ cao nhất:

Đo kiểm phải được thực hiện với thiết bị và các phương pháp đo kiểm môi trường gồm cả các hiện tượng môi trường yêu cầu tác động vào thiết bị, tuân theo thủ tục đo kiểm của IEC 60 068-2-2.

CHÚ THÍCH: Khuyến nghị rằng thiết bị được vận hành đầy đủ chức năng trước khi được đưa tới nhiệt độ hoạt động cận dưới của nó.

B.3. Độ rung

Khi các điều kiện về độ rung được chỉ định cho một đo kiểm, đo kiểm phải được thực hiện khi thiết bị được rung theo một trình tự được xác định theo khai báo của nhà sản xuất cho thiết bị đo kiểm. Đo kiểm phải sử dụng thiết bị và các phương pháp đo kiểm môi trường gồm cả các hiện tượng môi trường yêu cầu tác động vào thiết bị, tuân theo thủ tục đo kiểm của IEC 60 068-2-6. Các điều kiện môi trường khác phải nằm trong phạm vi được chỉ rõ trong điều B.1.

CHÚ THÍCH: Các mức rung cao hơn có thể gây ra ứng suất vật lý quá mức bên trong thiết bị sau một đợt đo kiểm kéo dài. Nhóm đo kiểm chỉ nên làm rung thiết bị trong quá trình đo RF.

B.4. Nguồn cung cấp

Khi các điều kiện về nguồn cung cấp tới hạn được chỉ định cho một đo kiểm, đo kiểm phải thực hiện với các giới hạn chuẩn trên và dưới của điện áp hoạt động được xác định theo khai báo của nhà sản xuất cho thiết bị đang đo kiểm.

Giới hạn điện áp trên:

Thiết bị phải được cung cấp một điện áp bằng giới hạn trên theo khai báo của nhà sản xuất thiết bị (khi được đo tại các đầu vào của thiết bị). Các đo kiểm phải thực hiện với các giới hạn nhiệt độ thấp nhất và cao nhất ở trạng thái ổn định theo khai báo của nhà sản xuất cho thiết bị, với các phương pháp quy định trong IEC 60 068- 2-1: Đo kiểm Ab/Ad và IEC 60 068-2-2: Đo kiểm Bb/Bd: Nung khô.

Giới hạn điện áp dưới:

Thiết bị phải được cung cấp một điện áp bằng giới hạn dưới theo khai báo của nhà sản xuất thiết bị (khi được đo tại các đầu vào của thiết bị). Các đo kiểm phải thực hiện với các giới hạn nhiệt độ thấp nhất và cao nhất ở trạng thái ổn định theo khai báo của nhà sản xuất cho thiết bị, với các phương pháp quy định trong IEC 60 068- 2-1: Đo kiểm Ab/Ad và IEC 60 068-2-2: Đo kiểm Bb/Bd: Nung khô.

B.5. Phép đo cho các môi trường đo kiểm

Độ chính xác đo của môi trường kiểm tra BS định nghĩa trong Phụ lục B là:

Áp suất: ±5 kPa.

Nhiệt độ: ±2 độ.

Độ ẩm tương đối: ±5%.

Điện áp một chiều: ±1,0%.

Điện áp xoay chiều: ±1,5 %.

Độ rung: ±10%.

Tần số rung: 0,1 Hz.

Các giá trị trên phải được áp dụng, trừ khi môi trường đo kiểm được kiểm soát và các yêu cầu kỹ thuật để kiểm soát môi trường đo kiểm có chỉ định độ không bảo đảm cho các tham số.

 

PHỤ LỤC C

(Tham khảo)

Sơ đồ đo

C.1. Máy phát

C.1.1. Công suất ra của trạm gốc, phát xạ không mong muốn

Hình C.1 - Thiết lập hệ thống đo công suất ra của trạm gốc, phát xạ không mong muốn

C.1.2. Xuyên điều chế máy phát

Hình C.2 - Thiết lập hệ thống đo xuyên điều chế máy phát

C.1.3. Lỗi hiệu chỉnh thời gian

Hình C.3 - Thiết lập hệ thống đo lỗi hiệu chỉnh thời gian

C.1.4. Công suất ra BS trong nhà để bảo vệ kênh lân cận

Hình C.4 - Thiết lập hệ thống đo công suất ra BS trong nhà để bảo vệ kênh lân cận

C.1.5. Công suất ra BS trong nhà để bảo vệ đồng kênh E-UTRA

Hình C.5 - (Tùy chọn 1) Thiết lập hệ thống đo công suất ra BS trong nhà để bảo vệ đồng kênh E-UTRA

Hình C.6 - (Tùy chọn 2) Thiết lập hệ thống đo công suất ra BS trong nhà để bảo vệ đồng kênh E-UTRA

C.2. Máy thu

C.2.1. Mức chọn lọc chuẩn

Hình C.7 - Thiết lập hệ thống đo mức chọn lọc chuẩn trạm gốc

C.2.2. Dải động

Hình C.8 - Thiết lập hệ thống do dải động

C.2.3. Chọn lọc trong kênh

Hình C.9 - Thiết lập hệ thống đo độ chọn lọc trong kênh

C.2.4. Chọn lọc kênh lân cận (ACS) và chặn băng hẹp

Hình C.10 - Thiết lập hệ thống đo độ chọn lọc kênh lân cận và chặn băng hẹp

C.2.5. Các đặc tính chặn

Hình C.11 - Thiết lập hệ thống đo các đặc tính chặn

C.2.6. Phát xạ giả máy thu

Hình C.12 - Thiết lập hệ thống đo phát xạ giả máy thu

C.2.7. Các đặc tính xuyên điều chế

Hình C.13 - Thiết lập hệ thống đo các đặc tính xuyên điều chế

 

THƯ MỤC TÀI LIỆU THAM KHẢO

[1] ETSI EN 301 908-1 (V11.1.1): "IMT cellular networks; Harmonised standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 1: Introduction and common requirements".

[2] ETSI EN 301 908-1 V11.1.1 (2016-07) IMT cellular networks: Harmonised Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 1: Introduction and common requirements.

 

原始文件(PDF)