Circular No. 11/2021/TT-BTTTT on Issuing the "National Technical Regulation on 5 GHz Band Wireless Access Equipment"

This regulation specifies technical requirements and measurement methods for wireless transmission equipment operating in the 5150-5825 MHz frequency band. It includes contents such as equipment declaration, equipment technical parameters, antenna usage methods, transmission modes, and channel availability check (CAC) requirements as well as the use of TPC technology.

Số hiệu11/2021/TT-BTTTT
Loại văn bảnCircular
Cơ quan ban hànhMinistry of Science and Technology
Người kýNguyễn Mạnh Hùng — Bộ trưởng
Cập nhật13/06/2026
NgànhInformation and Communications
Lĩnh vựcScience and TechnologyRadio Frequency
Ngày ban hành28/10/2021
Ngày áp dụng01/05/2022
Ngày hết hiệu lực
Tình trạngIn effect
✦ Tóm lược thông minh

This regulation specifies technical requirements and measurement methods for wireless transmission equipment operating in the 5150-5825 MHz frequency band. It includes contents such as equipment declaration, equipment technical parameters, antenna usage methods, transmission modes, and channel availability check (CAC) requirements as well as the use of TPC technology.

Đối tượng áp dụng

Wireless transmission equipment operating in the frequency range from 5150 MHz to 5825 MHz, including both standalone and combined or multi-radio equipment. This regulation applies to both Fixed Business Earth stations (FBE) and Land Mobile Business Earth stations (LBE).

Các điểm cốt lõi

  • Requirements for equipment information declaration, including channel allocation diagrams, designated central frequencies, and designated channel bandwidths.
  • Equipment technical specifications such as transmission power, capability to use Transmit Power Control (TPC).
  • Methods of using antennas and different transmission modes.
  • Requirements for channel availability check (CAC) for both FBE and LBE.
  • Measurement methods for conduction and radiation, including performing measurements when the equipment has integrated or separate antennas.

🌐 Tác động xã hội từ văn bản này

  • Ensuring the technical quality of wireless transmission equipment operating in this frequency range.
  • To effectively control and manage the use of radio frequency spectrum.
  • Providing a legal basis for measuring, evaluating, and certifying equipment before it is put into use.

❓ Câu hỏi thường gặp

Which devices must comply with this standard?

Wireless transmission equipment operating in the frequency range from 5150 MHz to 5825 MHz, including both standalone and combined or multi-radio equipment.

What requirements does this standard have regarding the use of TPC technology?

Equipment must declare the minimum and maximum transmission powers as well as various operational modes when using TPC technology.

Toàn văn

 

MINISTRY OF INFORMATION AND COMMUNICATION
COMMUNICATION

______

SOCIALIST REPUBLIC OF VIET NAM
Independence - Freedom - Happiness
_______________________

Number: 11/2021/TT-BTTTT

Hanoion 28 the 10 year 2021

 

THMR. TU

Issuing "National Technical Regulations on Access Equipment Operating in the 5 GHz Frequency Band"5 GHz frequency band

_______________________

On the basis of Law on Standards and Technical Regulations June 29, 2021 2006;

On the basis of Law on Telecommunications June 23, 11 ARTICLE 4. Finished traditional medicine is a form of traditional medicine that has undergone production processes, including packaging and labeling, using traditional or modern methods, belonging to one of the following forms: pills, liquids, tea, powder, extract, and other forms.

On the basis of Radio Frequency LawNo. wirelesspoliciestelecommunication June 23, 11 ARTICLE 4. Finished traditional medicine is a form of traditional medicine that has undergone production processes, including packaging and labeling, using traditional or modern methods, belonging to one of the following forms: pills, liquids, tea, powder, extract, and other forms.

Decree No. 127/2007/NĐ-CP August 1, 2007, of the Government detailing and guiding the implementation of certain provisions of the Standardization and Technical Regulation Law; BB 1.1dated May 16, 2018, of the Government amending and supplementing certain articles of Decree No.

Decree No. 78/2018/NĐ-CP August 1, 2007, of the Government detailing the implementation of certain provisions of the Standardization and Technical Regulation Law;"b) In addition to the lists of public services issued according to the provisions of Clause 2, Article 4 of this Decree, specialized agencies under provincial People's Committees shall report to the provincial People's Committee for decision-making on amending, supplementing, or issuing the list of public services funded by the state budget within their jurisdiction and consistent with the local budget capacity within the approved budget by the Provincial People's Assembly, and send it to the Ministry of Finance and relevant ministries and sectors for supervision during implementation."hereinafter referred to as the DecreeDeputy ministers of ministerial-level agencies, Technical Regulation Law; 127/2007/NĐ-CP 7/2017/NĐ-CP"b) In addition to the lists of public services issued according to the provisions of Clause 2, Article 4 of this Decree, specialized agencies under provincial People's Committees shall report to the provincial People's Committee for decision-making on amending, supplementing, or issuing the list of public services funded by the state budget within their jurisdiction and consistent with the local budget capacity within the approved budget by the Provincial People's Assembly, and send it to the Ministry of Finance and relevant ministries and sectors for supervision during implementation."hereinafter referred to as the DecreeDeputy ministers of ministerial-level agencies, At the proposal of the Director of the Science and Technology Department,uTechnology,

Decree No. 1The Minister of Information and Communications issues this Circular to stipulate National Technical Regulations on Access Equipment Operating in the 5 GHz Frequency Band. dated February 17, 2017 of the Government detailing the functions, tasks, powers, and organizational structure of the Ministry of Information and Communications;

Accompanying this Circular is the National Technical Regulation on Access Equipment Operating in the 5 GHz Frequency Band (QCVN 65:2021/BTTTT).ng1. This Circular takes effect from May 1, 2022.

2. The National Technical Regulation on Access Equipment Operating in the 5 GHz Frequency Band, designated as QCVN 65:2013/BTTTT, stipulated in Clause 1, Article 1 of Circular No. 01/2013/TT-BTTTT dated January 10, 2013, issued by the Minister of Information and Communications regarding National Technical Regulations on Telecommunications, shall cease to be effective from July 1, 2023.ng 1. From July 1, 2023, terminal access equipment operating in the 5 GHz frequency band imported and produced domestically must comply with the requirements set forth in QCVN 65:2021/BTTTT before being circulated in the market.

Article 1. 2. It is encouraged that enterprises, organizations, and individuals producing and importing access equipment operating in the 5 GHz frequency band apply the provisions of QCVN 65:2021/BTTTT from the date this Circular takes effect.

Article 2. Effectiveness

The Head of the Office, Directors of the Science and Technology Departments, Heads of agencies and units under the Ministry of Information and Communications, Directors of Provincial Information and Communications Departments, and relevant organizations and individuals are responsible for implementing this Circular./.

- The Prime Minister, Deputy Prime Ministers (for circulation);

Article 3. Tar Content

- The Central Party Committee Office and Party Committees;

- People's Supreme Court;

Article 4. - Supreme People's Procuracy;

Place of Receipt:
- Department of Legal Affairs (Ministry of Justice);
- Ministries, agencies equivalent to ministries, and government agencies;
- Provincial People's Councils, Provincial People's Committees;
- Official Gazette, Government Portal;
- National Assembly's Office;
- President's Office;
- Ministry of Information and Communications: Minister and Deputy Ministers, agencies and units under the Ministry, Ministry Portal;
QCVN 65:2021/BTTTT
- Provincial Departments of Information and Communications;
ON ACCESS EQUIPMENT OPERATING IN THE 5 GHz FREQUENCY BAND
radio access equipment operating in the 5 GHz band
1.    GENERAL PROVISIONS.. 5
- To be filed: VT, KHCN (250).

THE MINISTER




Nguyen Manh Hung

SOCIALIST REPUBLIC OF VIET NAM

 

 

 

1.1. SCOPE OF APPLICATION.. 5

 

AMENDMENT 1:2025 QCVN 07:2023/BXD

1.2. APPLICABLE SUBJECTS.. 5

 

 

National technical regulation

on 1.3. ENVIRONMENTAL CONDITIONS.. 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HANOI - 2021
Table of Contents

 

 

 

 

1.4. REFERENCED DOCUMENTS.. 5

1.5. DEFINITIONS.. 6

1.6. SYMBOLS.. 9

1.7. ABBREVIATIONS 10

2.    TECHNICAL REQUIREMENTS.. 11

2.1. DESIGNATED CENTER FREQUENCY.. 11

2.1.1.     DEFINITION. 11

2.1.2.     LIMITS.. 11

2.1.3.     MEASUREMENT.. 11

2.2. DESIGNATED CHANNEL BANDWIDTH AND OCCUPIED CHANNEL BANDWIDTH.. 11

2.2.1.     DEFINITION. 11

2.2.2.     LIMITS.. 11

2.2.3.     MEASUREMENT.. 12

2.3. RF TRANSMIT POWER, TRANSMIT POWER CONTROL (TPC), AND POWER DENSITY 12

2.3.1.     DEFINITION. 12

2.3.2.     LIMITS.. 12

2.3.3.     MEASUREMENT.. 13

2.4. UNINTENDED TRANSMISSION FROM TRANSMITTERS 13

2.4.1.     UNINTENDED TRANSMISSION OUTSIDE THE 5 GHz RLAN BAND. 13

2.4.1.1.   DEFINITION. 13

2.4.1.2.   LIMITS. 13

2.4.1.3.   MEASUREMENT... 14

2.4.2.     UNINTENDED TRANSMISSION FROM TRANSMITTERS WITHIN THE 5 GHz RLAN BAND. 14

2.4.2.1.   DEFINITION. 14

2.4.2.2.   LIMITS. 14

2.4.2.3.   MEASUREMENT... 15

2.5. FAKE RECEIVER TRANSMISSION.. 15

2.5.1.     DEFINITION. 15

2.5.2.     LIMITS.. 15

2.5.3.     MEASUREMENT.. 16

2.6. DYNAMIC FREQUENCY SELECTION (DFS).. 16

2.6.1.     REQUIREMENTS FOR FBE DEVICES.. 16

2.6.2.     REQUIREMENTS FOR LBE DEVICES.. 18

2.6.3.     SHORT CONTROL SIGNALING MECHANISM ON FBE AND LBE.. 23

 

 

2.7. RECEIVER INTERFERENCE REJECTION CAPABILITY.. 23

 

2.7.1.     DEFINITION. 23

2.7.2.     REQUIREMENTS.. 24

2.7.3.     MEASUREMENT.. 24

3.    TESTING METHODS.. 24

3.1. TESTING CONDITIONS... 24

3.1.1.     NORMAL AND LIMIT TESTING CONDITIONS.. 24

3.1.2.     REQUIREMENTS FOR NON-COMPLIANT TESTING CONDITIONS. 24

3.1.3.     TESTING SEQUENCES.. 25

3.1.4.     TESTING CHANNELS.. 25

3.1.5.     ANTENNAS.. 27

3.1.6.     CONDUCTED AND RADIATED MEASUREMENTS. 27

3.2. TESTING PROCEDURES... 27

3.2.1.     DEVICE DECLARATION 27

3.2.2.     FREQUENCY. 29

3.2.3.     OCCUPIED CHANNEL BANDWIDTH. 30

3.2.4.     RF OUTPUT POWER, TPC, AND POWER DENSITY 31

3.2.5.     UNINTENDED TRANSMISSION OUTSIDE THE 5 GHz BAND. 40

3.2.6.     UNINTENDED TRANSMISSION WITHIN THE 5 GHz RLAN BAND. 42

3.2.7.     FAKE RECEIVER TRANSMISSION.. 43

3.2.8.     ADAPTIVE ACCESS MECHANISM 45

3.2.9.     RECEIVER INTERFERENCE REJECTION CAPABILITY.. 59

4.    MANAGEMENT REQUIREMENTS.. 61

5.    RESPONSIBILITIES OF ORGANIZATIONS AND INDIVIDUALS.. 61

6.    IMPLEMENTATION ORGANIZATION.. 61

Appendix A (Regulation) Testing System and Radiation Measurement Layout. 62

Appendix B (Regulation) Procedures for Radiation Measurements. 69

Appendix C (Regulation) HS Code for Access Equipment Operating in the 5 GHz Frequency Band. 73

References. 74

QCVN 65:2021/BTTTT replaces QCVN 65:2013/BTTTT.

QCVN 65:2021/BTTTT was compiled by the Institute of Post and Telecommunications Science and Technology and the Science and Technology Department, reviewed by the Science and Technology Department, examined by the Ministry of Science and Technology, and promulgated together with Circular No. .../2021/TT-BTTTT dated ... month ... year 2021.

Appendix C (Provisions) Harmonized System Code for 5 GHz Radio Frequency Access Equipment. 73

References Directory.. 74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

 

Foreword

 

QCVN 65:2021/MIC superseded QCVN 65:2013/MIC.

QCVN 65:2021/MIC was compiled by the Institute of Post and Telecommunications Science and Technology and the Department of Science and Technology, reviewed by the Department of Science and Technology, and promulgated by the Ministry of Science and Technology through Circular number …/2021/TT-MIC dated ... month … year 2021.

 

 

 

 

 

 

 

 

 

 

AMENDMENT 1:2025 QCVN 07:2023/BXD

1.2. APPLICABLE SUBJECTS.. 5

National technical regulation

regarding radio access equipment operating in the 5 GHz band

 

1.      GENERAL PROVISIONS

1.1.    SCOPE

This national technical regulation applies to internal wireless network devices (5 GHz RLAN equipment) capable of operating across the entire or part of the frequency bands specified in Table 1.

This regulation sets out bandwidth access requirements for sharing bandwidth resources with other devices.

Table 1 - Frequency Bands for Operation of 5 GHz RLAN Equipment

Function

Bandwidth

Transmission

5 150 MHz to 5 350 MHz

Vehicle

5 150 MHz to 5 350 MHz

Transmission

5 470 MHz to 5 850 MHz

Vehicle

5 470 MHz to 5 850 MHz

 

The HS code for 5 GHz radio access equipment is as stipulated in Appendix C.

1.2.    APPLICABLE SUBJECTS

This regulation applies to organizations and individuals importing, manufacturing, and utilizing equipment capable of accessing the 5 GHz RLAN band within the scope of this regulation on the territory of Vietnam.

1.3.    ENVIRONMENTAL CONDITIONS

The technical requirements of this regulation apply under the operational environmental conditions published by the manufacturer. The equipment must comply with all technical requirements of this regulation when operating at the limits of the published operational environmental conditions.

1.4.    REFERENCED DOCUMENTS

ETSI TR 100 028-1: "Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Uncertainties in the Measurement of Mobile Radio Equipment Characteristics; Part 1".

R 100 028-2: "Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Uncertainties in the Measurement of Mobile Radio Equipment Characteristics; Part 2".

IEEE Std. 802.11TM-2016, IEEE Standard for Information Technology—Telecommunications and Information Exchange Between Systems—Local and Metropolitan Area Networks—Specific Requirements. Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications.

ETSI TS 136 141 (V13.5.0) (10-2016): "LTE; Evolved Universal Terrestrial Radio Access (E-UTRA); Base Station (BS) Conformance Testing (3GPP TS 36.141 version 13.5.0 Release 13).

1.5.    DEFINITIONS

1.5.1.      5 GHz RLAN Band (5 GHz RLAN band)

The band includes frequency ranges from 5 150 MHz to 5 350 MHz and from 5 470 MHz to 5 850 MHz.

1.5.2.      Adaptive Equipment (adaptive equipment)

Equipment operating in adaptive mode.

1.5.3.      Adaptive Mode (adaptive mode)

The mode of operation of the equipment that changes adaptively based on the operational environment conditions by identifying other transmission factors affecting the operating frequency band.

1.5.4.      Ad-Hoc Mode (ad-hoc mode)

The mode of operation of the equipment when directly and temporarily connected to another device without going through network management control.

1.5.5.      Antenna Array (antenna array)

Two or more antennas combined in a device and operating simultaneously.

1.5.6.      Antenna Assembly (antenna assembly)

Includes the antenna, coaxial cable, connectors, and switch components if used.

NOTE 1: The antenna assembly corresponds to the component in a transmission branch.

NOTE 2: Antenna gain refers only to the gain of the antenna itself, excluding gains due to technologies such as beamforming.

1.5.7.      Available Channel (available channel)

A channel determined to be immediately usable as an operational channel.

NOTE: Channels with defined bandwidth entirely within the range from 5 150 MHz to 5 250 MHz are available channels without the need for availability determination procedures.

1.5.8.      Backoff Procedure (backoff procedure)

A procedure allowing shared resource access by randomly selecting among devices requesting channel access to transmit information.

1.5.9.      Beamforming Gain (beamforming gain)

Gain achieved by using beamforming technology in smart antenna systems.

NOTE: Beamforming gain is independent and separate from antenna assembly gain.

1.5.10.   Burst

A period of continuous radio wave transmission expected before and after which no further transmissions are anticipated.

1.5.11.   Channel (channel)

The smallest amount of frequency spectrum used by a RLAN device to transmit and receive wireless information.

NOTE: A RLAN device may operate on one or several channels simultaneously.

1.5.12.   Channel Access Engine (CAE) Procedure

A procedure used to determine whether transmission is permitted.

1.5.13.   Channel Plan (channel plan)

A list including the center frequencies of channels along with their corresponding defined bandwidths.

1.5.14.   Clear Channel Assessment (CCA) Procedure

A procedure used by the device to determine whether the channel is being used by another device for transmitting information.

1.5.15.   Combined Equipment (combined equipment)

Equipment comprising multiple components, at least one of which has a function of receiving and transmitting wirelessly within the scope of this regulation.

1.5.16.   Contention Window (CW)

The primary parameter determining the duration of the backoff procedure.

1.5.17.   Dedicated Antenna (dedicated antenna)

An antenna located outside the device, connected to it via a connector, cable, or waveguide.

1.5.18.   Energy Detect (energy detect)

A mechanism used by the adaptive system to determine the presence of other devices operating in the channel by detecting the signal level transmitted by those devices.

1.5.19.   Environmental Profile (environmental profile)

The range of environmental conditions under which the equipment must comply with all regulations set forth in this regulation.

1.5.20.   Frame-Based Equipment (FBE)

Equipment that periodically transmits and receives with a fixed frame period (FFP).

1.5.21.   Integral Antenna (integral antenna)

Antenna designed as a fixed part of the device (without plug-in connector) and cannot be detached from the device to replace it with another antenna.

NOTE: Integrated antennas may be located inside or outside the device, but connected to the rest of the device by a cable or waveguide without a detachable plug-in connector.

1.5.22.   Listen Before Talk (LBT) Device

Device using the Clear Channel Assessment (CCA) function before utilizing the channel.

1.5.23.   Load Based Equipment (LBE)

Device that generates and performs wireless transmission and reception based on the amount of information required, not fixed over time.

1.5.24.   Master Mode

Mode of the device with Dynamic Frequency Selection (DFS) which detects radar interference (RID - Radar Interference Detection) to control other operating RLAN devices in Slave mode.

1.5.25.   Multi-Radio Equipment

Device combining at least two radio units (transmitter, receiver, or transceiver) or a radio unit capable of simultaneous operation on at least two frequency bands.

1.5.26.   Observation Slot

Time interval during which the device uses to check the presence of other RLAN devices on the operational wireless channel.

1.5.27.   Operating Channel

Available channel used by the RLAN device to initiate transmission and reception.

1.5.28.   Post Backoff Procedure

Backoff procedure applied immediately after each successful transmission.

1.5.29.   Prioritization Period

Time interval including initialization and observation for checking whether other RLAN devices perform transmission on the operational channel.

1.5.30.   Receive Chain

Part comprising the receiving circuit and corresponding antenna.

1.5.31.   Radio Local Area Network (RLAN) Device

Wireless access device operating in the 5 GHz band capable of use in internal radio networks.

1.5.32.   Simulated Radar Burst

Series of recurring radio pulses used for measurement purposes.

1.5.33.   Slave Mode

Mode where the transmission and reception of the RLAN device is controlled by the RLAN master device (Master) when performing DFS.

When set to Slave mode, the RLAN device is referred to as a Slave device.

1.5.34.   Smart Antenna Systems

Device combining multiple transmitting and receiving antennas capable of signal processing to enhance throughput or optimize wireless transmission and reception.

1.5.35.   Stand-Alone Radio Equipment

Device used in a radio network capable of independent operation.

1.5.36.   Sub-Band

A portion of the 5 GHz RLAN frequency band.

1.5.37.   Total Occupied Bandwidth

Sum of defined bandwidths when the device operates simultaneously on adjacent or non-adjacent channels.

1.5.38.   Transmit Chain

Part comprising the transmitting circuit and corresponding antenna.

1.5.39.   Transmit Power Control (TPC)

Technique allowing the output power of the radio transmitter to be controlled to reduce interference to other systems.

1.5.40.   Unavailability Channel

Channel unavailable for use by the RLAN device for a certain period of time (called Non Occupancy Period (NOP)) upon detection of radar signals on that channel.

1.5.41.   Unusable Channel

Channel declared unusable in the channel list due to detected radar signals.

1.5.42.   Usable Channel

Channel listed as usable by the RLAN device.

1.6.    Symbols

A                     Measured power at the output

D                     Measured power density

dBm                Ratio (in dB) relative to 1 milliwatt power

dBW              Ratio (in dB) relative to 1 watt power

E                     Field strength

E0                    Reference field strength

fc                     Carrier frequency

G                     Antenna gain

GHz                Gigahertz

Hz                  Hertz

kHz                Kilohertz

MHz                Megahertz

ms                  Millisecond

mW                 Milliwatt

n                      Number of channels

t,                    Priority cycle counter

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H                   EIRP calculated at maximum power level

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ||| EIRP is calculated at the lowest transmission power level

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:||| burst ||| Average power over the entire transmission cluster

||| PD Calculated power density

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:||| d ||| Detection probability

BB 1.6||| Counter related to the preventive procedure

||| R||| Distance

||| Rc Qu||| Number of active receiving chains

||| R0||| Reference distance

Provincial People's Committees set specific prices0||| Signal power

T0||| Time mark

T1||| Time mark

T2||| Time mark

T3||| Time mark

- Electronic Information Portal||| Radar pulse width

x||| Observation cycle

Y||| Gain due to beamforming

||| 1.7 Abbreviations

||| ACK

||| Confirmation

||| ACKnowledgement

||| AWGN

||| Gaussian white noise

||| Additive White Gaussian Noise

BW

||| Bandwidth

||| BandWidth

||| CCA

||| Channel assessment

||| Clear Channel Assessment

||| COT

||| Channel occupancy time

||| Channel Occupancy Time

DC

Discontinuous phenomenon applicable to transmitters

2.1 Electromagnetic Compatibility (EMC) Emission

||| DFS

||| Dynamic frequency selection

||| Dynamic Frequency Selection

||| e.i.r.p.

Equivalent Isotropically Radiated Power

||| Equivalent isotropic radiated power

||| e.r.p.

||| Effective radiated power

||| effective radiated power

||| ED

||| Energy detection

||| Energy Detect

||| FAR

||| Fully anechoic room

||| Fully Anechoic Room

||| IEEE

||| Institute of Electrical and Electronics Engineers

||| Institute of Electrical and Electronic Engineers

||| LBT

||| Listen before talk

||| Listen Before Talk

||| LPDA

||| Log-periodic dipole antenna

||| Logarithmic Periodic Dipole Antenna

||| OFDM

||| Orthogonal frequency division multiplexing

||| Orthogonal Frequency Division Multiplexing

||| PER

||| Packet error rate

||| Packet Error Rate

||| PHY

||| Physical layer

||| Physical Layer

||| ppm

||| Parts per million

||| parts per million

||| RBW

||| Resolution bandwidth

||| Resolution BandWidth

RF

Radio Frequency

Radio Frequency

||| RLAN

||| Radio local area network

||| Radio Local Area Network

||| RMS

||| Root mean square value

||| Root Mean Square

||| SAR

||| Semi-anechoic room

||| Semi Anechoic Room

TL

Limit

||| Threshold level

||| Transmit power control

||| Transmit Power Control

||| Tx

||| Transmitter

Generator

||| UUT

||| Unit under test

||| Unit Under Test

||| VBW

||| Video bandwidth

||| Band width Video

||| 2 Technical regulations

 

 

 

 

||| 2.1 Center frequency

 

||| 2.1.1 Definition

||| The assigned center frequency is the center frequency of the operating channel.

||| RLAN devices typically operate on one or several fixed frequencies. Devices are permitted to change the assigned operating frequency in case of interference detection or to avoid interfering with other devices and to comply with frequency planning requirements.

||| 2.1.2 Limitations

||| The assigned center frequency (f

) for a channel bandwidth of 20 MHz is defined according to (1):c||| 5 160 + (g x 20) MHz (1)

||| where,

||| is an integer satisfying 0 ≤ g ≤ 9 or 16 ≤ g The assigned center frequency may deviate from the value determined by expression (1) by no more than 200 kHz. The equipment manufacturer must declare the use of the assigned center frequency. g ≤ 29.

||| The actual center frequency for any given channel must be maintained within the range fc ± 20 ppm.

||| 2.1.3 Measurement

||| Use the measurement method specified in 3.2.2.

||| 2.2 Assigned channel bandwidth and occupied channel bandwidth

||| 2.2.1 Definition

||| Assigned channel bandwidth: the widest frequency band allocated to a single channel, including guard bandwidth.

||| Occupied channel bandwidth: the bandwidth that concentrates 99% of the signal power.

||| When the device transmits on multiple adjacent channels, the transmitted signal can be considered as originating from a single channel with an assigned channel bandwidth equal to "n" times the single-channel assigned channel bandwidth, where "n" is the number of consecutive adjacent channels.

||| When the device transmits on multiple non-adjacent channels, each channel used must comply with the regulations.

||| 2.2.2 Limitations

||| The assigned channel bandwidth for a single operating channel is 20 MHz.

||| Additionally, the device may use a minimum assigned channel bandwidth of 5 MHz if it still meets the requirements for the assigned center frequency in 2.1.

||| The occupied channel bandwidth must be within the range of 80% to 100% of the assigned channel bandwidth.

||| In the case of using a smart antenna system with multiple transmitting antennas, the assigned channel bandwidth and the occupied channel bandwidth on each branch must meet these requirements.

||| The occupied channel bandwidth may vary over time or with load.

||| During the COT period, the device may temporarily use an occupied channel bandwidth smaller than 80% of the assigned channel bandwidth but not less than 2 MHz.

||| 2.2.3 Measurement

||| Use the measurement method specified in 3.2.3.

||| 2.3 RF transmission power, transmit power control (TPC), and power density

||| 2.3.1 Definition

||| RF transmission power: the average value of the equivalent isotropic radiated power (e.i.r.p.) in a transmission cluster.

RF Output Power: The average value of the equivalent isotropic radiated power (e.i.r.p.) in a transmission cluster.

Power Control (TPC): The mechanism used by RLAN equipment to ensure at least 3 dB of attenuation from the total power caused by a large number of operating devices. RLAN equipment must be capable of reducing TPC by at least 6 dB below the average e.i.r.p. level within the limits set out in Table 2.

Power density is the equivalent isotropic radiated power (e.i.r.p.) density average in a transmission cluster.

The following limits may apply to the entire system and in any configuration, taking into account the antenna gain of integrated antennas or dedicated antennas as well as additional gain (beamforming) in the case of smart antenna systems.

In the case of multiple channels (adjacent or non-adjacent) within the same component band, the total RF output power of all channels within that component band shall not exceed the limit determined in Tables 2 and 3.

In the case of multiple non-adjacent channels operating in separate component bands, the total RF output power in each component band shall not exceed the limits determined in Tables 2 and 3.

2.3.2.      Limits

The following limits apply to the entire system in any configuration, taking into account the gain of integrated or dedicated antennas as well as additional gain due to the use of smart antennas. In the case where the device uses multiple consecutive or separated channels within the component band, the RF transmit power on the component band is determined by the sum of the powers on the channels and shall not exceed the limit. In the case where the device operates on channels outside the component band, the RF transmit power on each component band is the sum of the RF transmit powers of the channels within that band and shall not exceed the limit.

In the frequency range from 5150 MHz to 5250 MHz, the device is not required to use TPC.

For devices using TPC, the RF transmit power and power density when operating at the highest power level (Pmax) of the TPC range do not exceed the provisions set forth in Table 2.HIf the device does not use TPC, the limit is also specified in Table 2.

Table 2 - Average e.i.r.p. limits for determining RF transmit power and power density at the highest power level (Pmax).

Band (MHz)"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H)

Average e.i.r.p. limit at Pmax (dBm)

Average e.i.r.p. density limit (dBm/MHz)H With TPC

Without TPC

5150 to 5350

20/23 (Note 1)

5150 to 5350

20/23 (Note 1)

7/10 (Note 2)

23

5470 to 5850

10

30 (Note 3)

27 (Note 3)

17 (Note 3)

14 (Note 3)

NOTE 1: The limit applies at 20 dBm, except when transmitting with a defined bandwidth entirely within the 5150 MHz to 5250 MHz band, where the limit applies at 23 dBm.

NOTE 2: The limit applies at 7 dBm/MHz, except when transmitting with a defined bandwidth entirely within the 5150 MHz to 5250 MHz band, where the limit applies at 10 dBm/MHz.

NOTE 3: Slave devices without radar interference detection capability must comply in the band from 5250 MHz to 5350 MHz.

Table 3 - Average e.i.r.p. limits for determining RF transmit power at the lowest power level (Pmin).

Average e.i.r.p. limit at

 

24 (Note)"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ)

Bandwidth

NOTE: Slave devices without radar interference detection capability must comply in the band from 5250 MHz to 5350 MHz. "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ With TPC

7/10 (Note 2)

17

27 (Note 3)

2.3.3.      Measurement

Use the measurement method as specified in 3.2.4.

 

2.4.    Unwanted emissions from transmitters

2.4.1.      Unwanted emissions from transmitters outside the 5 GHz RLAN band

2.4.1.1.        Definition

Unwanted emissions from transmitters outside the 5 GHz RLAN band are emissions outside the 5 GHz RLAN band as defined in 1.5.1.

2.4.1.2.        Limits

The level of unwanted emissions from transmitters outside the 5 GHz RLAN band shall not exceed the levels specified in Table 4.

In the case of equipment with an antenna port, the above limits apply to emissions at the antenna port.

For enclosure ports or equipment using integrated antennas without an antenna port, the limit applies to the e.r.p. value at frequencies up to 1 GHz and e.i.r.p. at frequencies greater than 1 GHz.

Table 4 - Limits for unwanted emissions from transmitters outside the RLAN 5 GHz band

Frequency Range

Maximum Power

30 MHz to 47 MHz

-36 dBm

||| Bandwidth

100 kHz

47 MHz to 74 MHz

-54 dBm

74 MHz to 87.5 MHz

87.5 MHz to 118 MHz

-54 dBm

118 MHz to 174 MHz

47 MHz to 74 MHz

-54 dBm

174 MHz to 230 MHz

87.5 MHz to 118 MHz

-54 dBm

230 MHz to 470 MHz

47 MHz to 74 MHz

-54 dBm

470 MHz to 862 MHz

87.5 MHz to 118 MHz

-54 dBm

862 MHz to 1 GHz

47 MHz to 74 MHz

-54 dBm

1 GHz to 5.35 GHz

87.5 MHz to 118 MHz

-54 dBm

-30 dBm

47 MHz to 74 MHz

-54 dBm

5.35 GHz to 5.470 GHz

5.470 GHz to 26 GHz

2.2. Measurement Methods

2.4.1.3.        Measurement

5.470 GHz to 26 GHz

2.2. Measurement Methods

Use the measurement method as specified in 3.2.5.

5.470 GHz to 26 GHz

2.2. Measurement Methods

 

2.4.2.      Unwanted emissions from transmitters within the 5 GHz RLAN band

2.4.2.1.        Definition

Unwanted emissions from transmitters within the 5 GHz RLAN band as defined in 1.5.1.

2.4.2.2.        Limits

The power density (determined over a 1 MHz bandwidth) of unwanted emissions from transmitters within the 5 GHz RLAN band shall not exceed -30 dBm/MHz and the limit is defined by the spectrum mask in Figure 1. The limits in Figure 1 correspond to the maximum power density of the RLAN equipment over a 1 MHz bandwidth.

The spectrum mask in Figure 1 only applies to the operating band of the equipment. Outside the operating band of the equipment, the limits are defined as in 2.4.1.

Power density (measured over a 1 MHz bandwidth) of unwanted emissions from the transmitter in the 5 GHz RLAN band shall not exceed -30 dBm/MHz and the limit defined by the spectrum mask in Figure 1. The limits in Figure 1 correspond to the maximum power density of RLAN equipment on a 1 MHz bandwidth.

The spectrum mask in Figure 1 applies only to the operating band of the equipment. Outside the operating band of the equipment, the limit is determined as in 2.4.1.

In the case of using a smart antenna system with multiple transmission paths, the emission on each transmission chain must comply with the limits specified in Figure 1.

For devices transmitting simultaneously on adjacent channels, the above limits are applied as if the device were transmitting on a single channel with a bandwidth equal to n times the nominal bandwidth of each channel, where n is the number of adjacent channels being used simultaneously.

For devices transmitting simultaneously on non-contiguous channels, the application of the limits is carried out as follows:

- Unwanted emissions from the transmitter of each channel shall not exceed the mask spectrum shown in Figure 1;

- At each frequency, the highest mask spectrum level determined from the emissions of each channel used by the device shall be considered as the limit level within the corresponding mask spectrum at that frequency.

 

 

Reference Level

Frequency Deviation (MHz)

Relative Level (dB)

N ||| = Nominal Channel Bandwidth (MHz)

 

Figure 1 - Emission Spectrum Mask

2.4.2.3 Measurement

The measurement method as specified in 3.2.6 shall be used.

2.5 Spurious Transmitter Emissions

2.5.1 Definition

Any emissions on any frequency when the device is operating in receiver mode.

2.5.2 Limit

Spurious emissions at the receiver shall not exceed the limit levels specified in Table 5.

Table 4 - Limits for unwanted emissions from transmitters outside the RLAN 5 GHz band

Frequency Range

Table 5 - Limit Levels for Spurious Transmitter Emissions

30 MHz to 47 MHz

-36 dBm

Measured Bandwidth

30 MHz to 1 GHz

-57 dBm

-54 dBm

1 GHz to 26 GHz

-47 dBm

2.2. Measurement Methods

 

2.5.3 Measurement

The measurement method as specified in 3.2.7 shall be used.

2.6 Dynamic Frequency Selection (DFS) Mechanism

It is the mechanism used by the device to automatically limit transmission and perform access to operational channels.

RLAN will use the DFS function to detect interference from radar systems (radar detection) and to avoid co-channel operation with these systems.

The DFS function is described under conditions where the device may transmit, subject to the condition that transmission is permitted only if it does not violate the adaptive function requirements.

There are two types of adaptive devices:

- Frame-based Adaptive Equipment (FBE);

- Load-based Adaptive Equipment (LBE).

2.6.1 Requirements for FBE Devices

2.6.1.1 Introduction

FBE devices will implement the LBT access mechanism to detect signals from other RLAN devices transmitting on a specific operational channel.

FBE devices schedule reception and transmission periodically with a cycle defined by the FFP parameter. Each observation time slot used shall have a duration of no less than 9 ms.

A device initiating a series of one or more transmission signals is called an initiating device. Conversely, a device is called a responding device.

An FBE device may be an initiating device, a responding device, or both. The access mechanism for LBE initiating devices must comply with the provisions in 2.6.1.2. The access mechanism for LBE responding devices must comply with the provisions in 2.6.1.3.

If simultaneous transmission on adjacent or separate operational channels is possible, FBE is allowed to use any combination/group of 20 MHz operational channels within the list of designated central frequencies (see 2.1) if they meet the operational channel access requirements for initiating devices specified in 2.6.1.2 on each 20 MHz operational channel.

2.6.1.2 Access Mechanism for Initiating Devices

LBE initiating devices implement channel access according to the following requirements:

1) The manufacturer must declare the supported fixed frame period FFP intervals and these intervals must lie within the range of 1 ms to 10 ms. Signals can only be transmitted at the start of the FFP cycle as shown in Figure 2. The device may change the fixed frame period FFP but the maximum rate of change is only once every 200 ms.

2) Immediately before starting transmission on the operational channel at the beginning of the FFP cycle, FFP, the LBE device will perform a CCA check during an observation time slot. The operational channel will be considered occupied if the energy level exceeds the ED Threshold Level (TL) as required in this section. If the operational channel is determined to be unoccupied, the LBE device may transmit on it as shown in Figure 2. If the operational channel is detected as occupied, the device will not transmit on that channel in the next immediate FFP cycle. However, FBE is allowed to transmit short control signals on this channel if it complies with the requirements specified in 2.6.3. If simultaneous transmission on operational channels is possible, the device is allowed to transmit on any operational channel confirmed to be vacant through the CCA procedure. The total time that an FBE device is allowed to transmit on a specific operational channel without having to repeat the CCA procedure is called the Channel Occupancy Time (COT). During this time, the device may transmit multiple times on the operational channel without having to perform additional CCA procedures if the rest period between consecutive transmissions does not exceed 16 ms. If the expected start of transmission after the previous one is greater than 16 ms, the device must confirm the channel vacancy through a new CCA procedure immediately before transmission. All transmission stop periods are included in the COT.

3) An FBE initiating device is allowed to authenticate one or several related responding devices during the channel occupancy time. Authenticated responding devices must comply with the procedures specified in 2.6.1.3.

4) The Channel Occupancy Time (COT) shall not exceed 95% of the cycle

. The subsequent interval after the end of the occupancy period is called the Idle Time. The Idle Time shall not be less than 5% of the COT and not less than 100 ms.

4) Channel Occupancy Time (COT) shall not exceed 95% of the cycle. FFPThe subsequent period after channel occupancy ends is called idle time. Idle time shall not be less than 5% of COT and not less than 100 ms.

5) Upon receiving the intended data packet, the device may bypass the Clear Channel Assessment (CCA) to immediately process and transmit management and control frames such as ACKs. The total time the device continuously performs transmission processing without conducting a new CCA must not exceed the maximum COT value as specified in step (4) of this section. For multi-cast transmissions, corresponding ACK information from other devices for the same data packet may be transmitted consecutively.

6) Limit ED Threshold Level (TL) at the receiver input is determined according to the maximum transmission power expressed by the following formula (assuming an omnidirectional receiving antenna and using e.i.r.p. in dBm):

            -75 dBm/MHz, if "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H ≤ 13 dBm;

            -85 dBm/MHz + (23 dBm - "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H) if 13 dBm < "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H < 23 dBm;

            -85 dBm/MHz, if "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H ≥ 23 dBm.            

 

||| Unit under test

||| CCA

||| CCA

||| CCA

||| CCA

UUT Transmits

Waiting Time

Waiting Time

||| Channel occupancy time

||| Channel occupancy time

Fixed Frame

Fixed Frame

 

Figure 2 - Structure within the fixed frame period FFP

2.6.1.3.        Access mechanism of the responding device

Requirement 3) in 2.6.1.2 stipulates that the initiating device grants permission to the responding device to transmit on the operational channel during the current fixed frame period FFP. The responding device, upon receiving permission to transmit, must comply with procedures from steps 1) to 3) of this section.

1) A responding device granted permission to transmit by an initiating device may transmit on the operational channel as follows:

a) The responding device may transmit without performing the CCA monitoring procedure if the transmission time is no more than 16 ms from the previous transmission time of the initiating device granting permission. initiating granting permission.

b) The responding device must not transmit within 16 ms from the previous transmission time of the initiating device granting permission and must perform the CCA channel check procedure on the operational channel before transmitting. The CCA procedure must be performed within a monitoring time slot not exceeding 25 ms from the previous transmission time of the initiating device.

If the signal detected during monitoring exceeds the threshold level (TL) specified in step 6) of 2.6.1.2, the responding device must follow step 3) of this section. Otherwise, the responding device follows step 2) of this section. ED Threshold Level 2) The responding device may transmit on the operational channel during the remaining COT period of the current cycle. The responding device (Responding Device) may transmit multiple times on the operational channel if the interval between consecutive transmissions does not exceed 16 ms. Upon completing the transmission, the responding device will follow the procedure in step 3).

b) The responding device must not transmit within 16 ms from the previous transmission time of the initiating device granting permission and must perform the CCA channel check procedure on the operational channel before transmitting. FFP 3) The responding device loses permission to transmit.2.6.2.      Requirements for the LBE device 2.6.2.1.        Introduction

The LBE device shall implement the Listen Before Talk (LBT) channel access mechanism to detect whether there is an RLAN signal transmission on the operational channel.

2.6.2.2.        Adaptive classification

The LBE device may be classified as an initiating device, a responding device, or both types. The access mechanism for the LBE initiating device must comply with the provisions in 2.6.2.6. The access mechanism for the LBE responding device must comply with the provisions in 2.6.2.7.

The LBE device transmits during the COT periods. Each COT includes at least one transmission period of the initiating device and may also include transmission periods of corresponding responding devices.

A controlling device (not DFS) that manages the operating parameters of one or several other devices is called a supervising device. Conversely, the devices controlled by the supervising device are called supervised devices.

2.6.2.3.        Multi-channel usage

A device initiating a series of one or more transmission signals is called an initiating device. Conversely, a device is called a responding device.

If simultaneous transmission capability exists on adjacent or separate operational channels, the LBE must meet the following option:

- The LBE is permitted to use any combination/group of 20 MHz operational channels within the defined central frequency list (in Article 2.1) if it meets the channel access requirements for the initiating device specified in 2.6.2.6 on each 20 MHz operational channel;

- The LBE uses a combination/group of 20 MHz channels within a 40 MHz, 80 MHz, or 160 MHz link channel and can transmit on any 20 MHz operational channel if it meets the channel access requirements for the initiating device specified in 2.6.2.6 on one of the 20 MHz operational channels (called the primary operational channel) and performs a CCA check for at least 25 ms to determine that there is no signal with a level greater than the ED Threshold Level (TL) (see 2.6.2.5) on another operational channel to be used.

The 40 MHz, 80 MHz, and 160 MHz link channels are arranged as shown in Figure 3.

20 MHz Channel

40 MHz Channel

80 MHz Channel

160 MHz Channel

Figure 3 - Arrangement of 40 MHz, 80 MHz, 160 MHz Channels

 

 

The selection of the primary operational channel is carried out in one of the following two ways:

-      Randomly selecting each time the corresponding contention window CW associated with a transmission of the primary operational channel is set to the minimum CW

. The CW will remain unchanged for each priority class (see 2.6.2.4) in a 20 MHz component channel of a 40 MHz, 80 MHz, or 160 MHz link channel;

-      Randomly selecting and not changing more than once in one second.

 

The 40 MHz, 80 MHz, and 160 MHz link channels containing groups of 20 MHz operational channels will not change more than once in one second.

2.6.2.4.        Priority classes

Table 7, Table 8 contain four sets of channel access parameters corresponding to supervising and supervised devices, creating priority classes and the largest COT parameter. These parameters are used by the initiating device in the channel access mechanism (at 2.6.2.6) to access the operational channel.Maximum Downhill GradientThe CW window will remain unchanged for each priority class (see 2.6.2.4) in a 20 MHz component channel of a 40 MHz, 80 MHz, or 160 MHz link channel.

- Random selection and not changed more than once in one second.

A 40 MHz, 80 MHz, or 160 MHz link channel containing a group of 20 MHz operational channels shall not change more than once in one second.

2.6.2.4 Priority Classes

Tables 7 and 8 contain four sets of channel access parameters corresponding to monitoring and monitored devices, creating priority classes and the largest COT values. These parameters are used by initiating devices in the channel access mechanism (at 2.6.2.6) to access operational channels.

If the occupied channel contains at least two transmission segments, the transmission segments must be separated by a specific guard interval. The Channel Occupancy Time (COT) is determined by the sum of all transmission intervals and guard intervals not exceeding 25 ms within the occupied channel. The value of COT shall not exceed the maximum value specified in Table 7 and Table 8. The distance between the last transmission time point to the first transmission time point in an occupied channel shall not exceed 20 ms.

The initiating device may transmit on different priority classes. In such cases, the channel access mechanism simultaneously uses the corresponding Channel Occupancy Engine (COE) tools for each different priority class defined in 2.6.2.6.Channel Occupancy Enginecorresponding to each different priority class specified in 2.6.2.6.

Table 7 - Channel Access Parameters for Different Priority Classes (Initiating Device)

Class

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:0

CWMaximum Downhill Gradient

CWmax

Maximum Channel Occupancy Time (COT)

4

1

3

7

2 ms

3

1

7

15

4 ms

2

3

15

63

6 ms (Note 1, 2)

1

7

15

1023

6 ms (Note 1)

NOTE 1: The maximum COT value of 6 ms can be increased to 8 ms by inserting additional stop intervals with a minimum length of 100 ms. The maximum COT value excluding stop intervals remains 6 ms.

NOTE 2: The maximum COT value of 6 ms can be increased to 10 ms by extending CW to CW x 2 + 1 when selecting the number of random intervals before the channel occupancy time exceeds 6 ms or after the channel occupancy time exceeds 6 ms. The use of pre- or post-occupancy reserves must not change during the operation period of the device. BB 1.6 for pre-COT reserves that may be greater than 6 ms or post-COT reserves larger than 6 ms. The use of pre-COT or post-COT reserves must not change during the device's operational period.

NOTE 3: The values for P0, CWMaximum Downhill Gradient, CWmax are the smallest values that can be used.

Table 8 - Channel Access Parameters for Different Priority Classes (Responding Device)

Class

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:0

CWMaximum Downhill Gradient

CWmax

Maximum Channel Occupancy Time (COT)

4

2

3

7

2 ms

3

2

7

15

4 ms

2

3

15

1023

6 ms (Note 1)

1

7

15

1023

6 ms (Note 1)

NOTE 1: The maximum COT value of 6 ms can be increased to 8 ms by inserting additional stop intervals with a minimum length of 100 ms. The maximum COT value excluding stop intervals remains 6 ms.

NOTE 2: Values for P0, CWMaximum Downhill Gradient, CWmax NOTE 2: The values for P

are the smallest values that can be used. ED Threshold Level

2.6.2.5 Detection Threshold Level If the operational channel is detected as occupied, the device will not transmit on that channel in the next immediate FFP cycle. However, FBE is allowed to transmit short control signals on this channel if it complies with the requirements specified in 2.6.3.. If the operational channel is detected as occupied, the device will not transmit on that channel in the next immediate FFP cycle. However, FBE is allowed to transmit short control signals on this channel if it complies with the requirements specified in 2.6.3. A device will consider the channel occupied when it detects an RLAN signal level greater than

N ||| Limit value If the operational channel is detected as occupied, the device will not transmit on that channel in the next immediate FFP cycle. However, FBE is allowed to transmit short control signals on this channel if it complies with the requirements specified in 2.6.3. defined over the entire bandwidth of all operational channels used by the device.

depending on the type of device:TM- Option 1: For devices operating in the RLAN 5 GHz band complying with one or more of clauses 17, 19, 21 in the IEEE 802.11 If the operational channel is detected as occupied, the device will not transmit on that channel in the next immediate FFP cycle. However, FBE is allowed to transmit short control signals on this channel if it complies with the requirements specified in 2.6.3. -2016 standard, the value"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:Hdoes not depend on the maximum transmission power of the device ( If the operational channel is detected as occupied, the device will not transmit on that channel in the next immediate FFP cycle. However, FBE is allowed to transmit short control signals on this channel if it complies with the requirements specified in 2.6.3. ). Assuming the use of an antenna with a gain of 0 dBi, the value

 

will be determined as:dBm/MHz

(2)

- Option 2: For devices complying with Option 1 and at least one other operating mode, or for devices not complying with Option 1, the value If the operational channel is detected as occupied, the device will not transmit on that channel in the next immediate FFP cycle. However, FBE is allowed to transmit short control signals on this channel if it complies with the requirements specified in 2.6.3. depends on the maximum transmission power of the device ("5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:Hdoes not depend on the maximum transmission power of the device ( If the operational channel is detected as occupied, the device will not transmit on that channel in the next immediate FFP cycle. However, FBE is allowed to transmit short control signals on this channel if it complies with the requirements specified in 2.6.3. ). Assuming the use of an antenna with a gain of 0 dBi, the value

 

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H ≤ 13 dBm: TL = -75 dBm/MHz

13 dBm <"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H ≤ 23 dBm: TL = -85 dBm/MHz + (23 dBm - "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H)

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H > 23 dBm: TL = -85 dBm/MHz

(3)

2.6.2.6 Initiating Device Access Mechanism

Before transmitting on an operational channel, the initiating device must activate and operate at least one COE procedure to perform the steps from 1) to 8) below. The COE procedure uses parameters specified in Table 7 and Table 8.

The observation window defined in 1.5.26 and used herein shall not be less than 9 ms.

The initiating device will use from 1 to 4 different COE procedures corresponding to each priority class defined in 2.6.2.4.

1)

The COE procedure sets CW 1. Voluntary drug rehabilitation participants CWMaximum Downhill Gradient.

2)

The COE procedure randomly selects a number BB 1.6 within the range from 0 to CW. Note 2 in Table 7 defines a different range of BB 1.6 when the preceding or subsequent COT interval is larger than the maximum COT value specified in Table 7.

3)

The COE procedure initiates a priority time interval as prescribed from step 3a) to step 3c):

 

a)

The COE procedure sets the parameter t, according to the corresponding priority class as in 2.6.2.4

 

b)

The COE procedure waits for 16 ms

 

c)

The COE procedure performs the ||| CCA procedure on the operational channel within the observation window.

 

 

i)

The operational channel will be considered occupied if there is a signal on the channel greater than the detection threshold ED Threshold as in 2.6.2.5. At that time, the COE procedure will initiate a priority time interval according to step 3a) after the detected signal in the channel is lower than the detection threshold ED Threshold;

 

 

ii)

In case the signal on the operational channel is lower than the detection threshold ED Threshold, t, may be reduced by a decrement not exceeding 1. If t, equals 0, the COE procedure will proceed to step 4). Otherwise, the COE procedure will proceed to step 3c);

4)

The COE procedure will perform the fallback procedure according to steps from 4a) to 4d) as follows:

 

a)

Determine whether the COE procedure meets the fallback condition. If BB 1.6 < 0 and in a ready-to-transmit state, the COE procedure will set CW 1. Voluntary drug rehabilitation participants CWMaximum Downhill Gradient and select a random number BB 1.6 uniformly distributed in the range from 0 to CW before performing step 4b). Note 2 in Table 7 defines a different range of BB 1.6 when the preceding or subsequent interval is larger than the maximum ||| COT value specified in Table 7. ||| COT < 1, the COE procedure will proceed to step 4d). Otherwise, the COE procedure may reduce

 

b)

If BB 1.6 by a value not exceeding 1 and proceed to step 4c); BB 1.6 CCA

 

c)

The COE procedure performs the on the operational channel within a single observation window as follows:as in 2.6.2.5. At that time, the COE procedure will continue to perform step 3.

 

 

i)

The operational channel will be considered occupied if there is a signal on the channel greater than the detection threshold ED Threshold , the COE procedure will proceed to step 4b);

 

 

ii)

In case the signal on the operational channel is lower than the detection threshold ED ThresholdIf ready to transmit, the COE procedure will continue to step 5). Otherwise, the COE procedure will reduce the value

 

d)

by 1 and perform processing according to step 4c). Note that the value BB 1.6 may be less than 0 and decrease gradually while the COE procedure is not ready to transmit; BB 1.6 If only one COE procedure of the initiating device is processing at this step (Note 1), that COE procedure will proceed to step 6). If more than one COE procedure of the initiating device is at this step (Note 2), the COE procedure with the highest priority will proceed to step 6) and the remaining COE procedures will proceed to step 8).

5)

NOTE 1: In the case where the device has no internal conflict;

 

NOTE 2: In the case where the device has an internal conflict;

The COE procedure may start transmitting with the corresponding or higher priority on one or more operational channels. If transmitting on multiple operational channels, the initiating device must meet all requirements in 2.6.2.3:

6)

The CAE procedure may start transmitting at the corresponding or higher priority level on one or more operational channels. If transmitting on multiple operational channels, the initiating device must meet all requirements in 2.6.2.3:

 

a)

CAE may transmit multiple times without performing the CCA procedure on the operating channel if the interval between transmissions does not exceed 16 ms. Conversely, if the interval between transmissions exceeds 16 ms but does not exceed 25 ms, the initiating device may continue to transmit if no signal exceeding the threshold level is detected on the operating channel during the observation time slot;

 

b)

CAE may grant transmission rights on the current operating channel to one or more responding devices. If granted transmission rights by the initiating device, the responding device must follow the procedures specified in 2.6.2.7;

 

c)

The initiating device may transmit simultaneously with lower priority levels than the priority level being used by CAE, provided that the transmission duration does not exceed the time required for CAE to transmit at the determined priority level;

7)

Upon completion of channel occupation and confirmation of at least one successful transmission at the start of channel occupation, the initiating device will proceed with step 1). Otherwise, the initiating device will proceed with step 8);

8)

The initiating device may retransmit. If the device does not retransmit, CAE will ignore all data packets within the channel occupation period and proceed with step 1). Otherwise, CAE will set CW to (CW + 1) x CW - 1 with CW m ≥ 2. If the value of CW after setting is greater than the value of CW m , CAE will set CW to CW CW . CAE will then proceed with step 2); CWmax, According to the provisions in 2.6.2.4, the initiating device must operate with separate CAEs for each priority class; CWmaxmay take a value greater than the level

defined in steps 1) to 8) of this section;

CW 2.6.2.7        Access mechanism of responding devices; CW Step 6b) in 2.6.2.6 determines the ability of the initiating device to allow one or more responding devices to transmit on the current operating channel. When granted permission, the responding device

will follow steps 1) to 3) as follows:

A responding device granted transmission rights from the initiating device may transmit on the current operating channel as follows: The responding device may transmit immediately without performing the CCA procedure if the transmission time is within 16 ms of the last transmission time of the corresponding initiating device; The responding device must perform the CCA procedure on the operating channel during the observation time slot within 25 ms before the granted transmission time if it does not transmit for 16 ms following the cessation of transmission by the corresponding initiating device. If a signal exceeding the threshold level

1)

is detected on the operating channel, the responding device will proceed to step 3). Otherwise, the device will proceed to step 2);

 

a)

The responding device may transmit on the current operating channel during the remaining time. The responding device may transmit multiple times on the operating channel during this time if the interval between consecutive transmissions does not exceed 16 ms. Upon completion of transmission, the responding device will proceed to step 3;

 

b)

Withdrawal of transmission rights for the responding device; ED Threshold2.6.3.      Short control signaling transmission mechanism on FBE and LBE;

2)

2.6.3.1.        Definitions; ||| COT Short control signaling is used by devices to transmit management and control frames without monitoring the presence of other signals on the channel;

3)

FBE and LBE devices are permitted to transmit short control signaling on the operating channel if the transmission complies with the provisions in this section. Devices may or may not use short control signaling transmission;

2.6.3.2.        Requirements;

Transmission of short control signaling must comply with the following requirements:

-      In each 50 ms observation cycle, the number of times a device transmits short control signaling shall not exceed 50;

-      The total transmission time of short control signaling by the device must be less than 2,500 ms in the observation cycle;

2.6.3.3.        Measurement method;

Use the measurement method as specified in 3.2.8;

2.7.    Receiver blocking characteristics;

2.7.1.      Definitions;

The receiver blocking characteristic is the capability of the device to receive the desired signal on the operating channel with acceptable quality when unwanted signals (blocking signals) are present at the input at frequencies outside the specified frequency band in Table 1;

Quality is assessed through the packet error rate (PER) with a limit of 10%. For special cases due to other purposes, the manufacturer must declare the specific quality limit used;

2.7.2.      Requirements;

The device must ensure the quality limit when unwanted signals are present at specified frequencies not less than the limits in Table 9;

Table 9 - Blocking signal parameter limits;

Desired average power (dBm);

Blocking signal frequency;

Blocking signal power, dBm (Note 2);

Type of blocking signal;

Master/Slave capable of detecting radar;

Slave incapable of detecting radar;

Continuous wave (CW);

NOTE 1:

is the lowest desired signal level (in dBm) to meet the quality limit in 2.7.1 when there is no blocking signal;

NOTE 2: The levels in the table correspond to before the antenna of the evaluated device. In the case of lead-in measurements, the levels apply to the measured signal at the antenna jack;

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:Maximum Downhill Gradient+ 6

5 100

-53

-59

2.7.3.      Measurement method;

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:Maximum Downhill Gradient+ 6

4 900

5 000

5975

-47

-53

2.7.3.      Measurement method;

Use the measurement method as specified in 3.2.9;"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:Maximum Downhill Gradient 3.      MEASUREMENT METHODS;

3.1.    Measurement conditions;

3.1.1.      Normal and extreme measurement conditions;

The measurements in this standard will be conducted under normal measurement conditions as follows:

 

 

-      Temperature: from 15°C to 35°C;

-      Humidity: from 20% to 75%;

-      Power supply: according to the operational requirements of the device;

The above measurement conditions must be recorded in the Measurement Results Report;

In the case of extreme measurement conditions, the manufacturer must declare the extreme environmental conditions used for the device; 03.1.2.      Requirements for non-compliance with measurement conditions; 0C

- Humidity: from 20% to 75%;

- Power supply: according to the device's operational requirements.

The above measurement conditions parameters must be recorded in the Measurement Results Report.

In case the equipment is required to be tested under extreme conditions, the manufacturer must declare the extreme environmental conditions of the equipment used.

3.1.2 Requirements for Unreliable Measurement

The degree of non-compliance of measurements shall not exceed the limit set out in Table 10.

Table 10 - Maximum Degree of Non-compliance

Parameter

Maximum Non-compliance

Frequency

±10 ppm

RF Power Output

±1.5 dB

RF Radiated Power

±6 dB

Unwanted Emission Output

±3 dB

Unwanted Radiated Emission

±6 dB

Moisture content

±5 %

Salinity

±2 0C

Time

±10 %

3.1.3.      Measurement Chains

Except for DFS-related tests, the tests in this standard are conducted using measurement transmission chains. These chains include data packets transmitted at regular intervals over a specified period (e.g., 2 ms). The transmission time within the test measurement chain is fixed and exceeds 10% of each cycle's duration.

The general structure of the measurement chain is illustrated in Figure 4.

 

UUT Data Packet

 

Figure 4 - Measurement Chain

3.1.4.      Test Channels

Unless otherwise specified, the channels used in the tests are defined in Table 11.

When measuring devices that support simultaneous transmission on consecutive or discrete channels, DFS tests do not need to be performed simultaneously on corresponding channels.

 

Table 11 - Test Channels

Measurement

Article/Section

Test Channel

Low Band (5 150 MHz to 5 350 MHz)

High Band (5 470 MHz to 5 850 MHz)

5 150 MHz -

5 250 MHz

5 250 MHz -

5 350 MHz

 

 

 

 

 

Center Frequency

2.1

C7 (Note 1)

C8 (Note 1)

Occupied Channel Bandwidth

2.2

White letter papers not containing mechanical pulp, selected. Proportion of ledger papers, carbon paper, and water-soluble glue not exceeding.

White office paper types not containing mechanical pulp. Proportion of colored copied papers not being carbon paper (%) not exceeding.

Power Density

2.3

C1.

C2.

C3, C4

Out-of-Band Transmitter Emissions

2.4.1

C7 (Note 1)

C8 (Note 1)

In-Band Transmitter Emissions

2.4.2

C1.

C2.

C3, C4

Receiver Interference Signal

2.5

C7 (Note 1)

C8 (Note 1)

Transmit Power Control (TPC)

2.3

NA

(Note 2)

C2.

 (Note 1)

C3, C4

(Note 1)

Dynamic Frequency Selection (DFS)

2.6

NA

(Note 2)

Card types mimicking leather not containing mechanical pulp. Proportion of colored print (%) not exceeding.

C6 (Note 3)

Adaptation

2.6

White office paper types not containing mechanical pulp, without colored copied papers not being carbon paper.

Receiver Blocking Characteristics

2.7

White letter papers not containing mechanical pulp, selected. Proportion of ledger papers, carbon paper, and water-soluble glue not exceeding.

White office paper types not containing mechanical pulp. Proportion of colored copied papers not being carbon paper (%) not exceeding.

C1, C3:

The lowest declared channel corresponding to each nominal channel bandwidth within the band. For power density measurements, only the smallest nominal channel bandwidth needs to be measured.

C2, C4:

The highest declared channel corresponding to each nominal channel bandwidth within the band. For power density measurements, only the smallest nominal channel bandwidth needs to be measured.

C7, C8:

One of the channels within the band. The occupied channel bandwidth measurement will be performed with each declared value for measurement.

C9:

One (for single-channel measurement) or a group of channels (for multi-channel measurement) among the declared channels.

NOTE 1:

If there are multiple declared channel lists, the measurement only needs to be performed with one of the channel lists.

NOTE 2:

NOTE 3:

 

No measurement is required when the nominal channel bandwidth lies entirely within the 5 150 MHz to 5 250 MHz band.

In cases where the declared channel set includes channels with nominal channel bandwidths fully or partially reduced within the 5 600 MHz to 5 650 MHz band, the channel availability tests (and if applicable, off-channel CAC tests) will be performed on one of these channels outside the 5 470 MHz to 5 600 MHz band or within the 5 650 MHz to 5 725 MHz band.

of these channels other than a channel in the band 5 470 MHz to 5 600 MHz or in the band 5 650 MHz to 5 725 MHz.

of these channels, add a channel in the band 5 470 MHz to 5 600 MHz or in the range 5 650 MHz to 5 725 MHz.

of these channels, add a channel in the band 5 470 MHz to 5 600 MHz or in the range 5 650 MHz to 5 725 MHz.

Can't load full results

Try again

Retrying...

Retrying...

 

             

3.1.5.      Antennas

3.1.5.1.        Integrated and External Antennas

Devices may have integrated antennas or external antennas. External antennas (external antennas) are antennas located outside the device and must meet relevant requirements in the standard when combined with the device.

In the standard, antenna system components include antennas, cables, connectors, and switching parts. Antenna gain does not include gain created by advanced quality technologies such as beamforming, spatial multiplexing, etc.

Smart antenna systems may use beamforming techniques to enhance gain. The enhanced gain due to these measures will be determined separately and independently from the inherent gain of the antenna.

Although measurement methods in the standard include both direct and radiated measurements, it should be noted that the device and antenna combination must meet all relevant requirements in the standard.

3.1.5.2.        Transmission Modes

Mode 1: Single Antenna Usage

The device uses only one antenna, including:

-      Device with a single antenna;

-      Device with two spatially multiplexed antennas but connected to only one antenna at a given time;

-      Smart antenna system with multiple antennas but using only one antenna during the measurement mode.

Mode 2: Multiple Antennas, No Beamforming

The device in this mode uses a smart antenna system with multiple simultaneous transmitting antennas but does not use beamforming technology.

Mode 3: Multiple Antennas and Beamforming Technology

The device in this mode uses a smart antenna system with multiple simultaneous transmitting antennas, supporting beamforming technology.

In addition to the antenna system gain G, beamforming gain Y must also be considered when performing measurements.

3.1.6.      Direct and Radiated Measurements

Unless otherwise specified, both direct and radiated measurements must be performed.

Devices using integrated antennas must have connectors available for direct measurements.

In the absence of connectors for measurement, the device manufacturer must add measurement connectors to the device under test.

3.2.    Tests

3.2.1.      Device Declaration

The device manufacturer must declare the following information to be included in the measurement report. This information is used for conducting measurements and evaluating results.

-      Channel allocation diagram, declared center frequencies, and declared channel bandwidths;

- If the LBE device supports multi-channel transmission, the following information must be declared:

· Option (1 or 2) used by the LBE when performing multi-channel transmission;

· The maximum number of channels used simultaneously;

· Type of channels used simultaneously: consecutive or non-consecutive;

· Capability to use channels at different component band frequencies;

· Number of channels used for measurement when the device operates under Option 1.

- Different transmission modes are used;

- For each transmission mode, the following information must be declared:

· Number of transmission chains;

· If more than one transmission chain is activated, power distribution among the activated chains is uniform or non-uniform;

· Number of reception chains;

· Capability to use antenna beamforming and maximum beamforming gain in transmission mode; Y - Characteristic parameters of TPC used by the device;

NOTE: The device may use multiple TPC bands on antennas or require different powers. The manufacturer may declare whether the device uses or does not use TPC.

- For devices using TPC, the manufacturer must declare the following information for each TPC band:

· Minimum and maximum transmission power levels (e.i.r.p. in case of integrated antennas). If simultaneous transmission across different component bands is supported, the declaration includes minimum and maximum transmission power levels for each component band;

· Different transmission power levels corresponding to different operating modes in case of smart antennas with different transmission modes;

· Components of the antenna system, maximum gain, e.i.r.p. corresponding (taking into account beamforming gain if applicable) and threshold level

DFS Threshold Level G· Frequency range of operation; Y - For devices not using TPC, the manufacturer must declare the following information: · Maximum transmission power level (e.i.r.p. in case of integrated antennas). If simultaneous transmission across different component bands is supported, the declaration includes maximum transmission power level for each component band;;

- Device's DFS operating modes (Master, Slave with radar detection capability or without radar detection capability);

- Direct connection mode frequency (ad-hoc) if the device can operate in this mode;

- Operating frequency band of the device;

· Components of the antenna system, maximum gain, e.i.r.p. corresponding (taking into account beamforming gain if applicable) and threshold level

DFS Threshold Level G· Frequency range of operation; Y - For devices not using TPC, the manufacturer must declare the following information: · Maximum transmission power level (e.i.r.p. in case of integrated antennas). If simultaneous transmission across different component bands is supported, the declaration includes maximum transmission power level for each component band;;

- Device's DFS operating modes (Master, Slave with radar detection capability or without radar detection capability);

- Operating environment (normal or harsh);

- Measurement software used by the UUT;

- Device type: standalone, combined device or multi-radio device;

- Adaptive device type: FBE or LBE;

- For FBE devices, the following information must be declared:

· FBE operating mode: initiating device and/or responding device;

· Time interval

used by the device;

- For LBE devices, the following information must be declared:

· LBE operating mode: monitoring device and/or monitored device; FFP · Capability to use Note 1 in Table 7 or Note 1 in Table 8;

· Capability to use Note 2 in Table 7 when the LBE is a monitoring device;

· Initiating device and/or responding device mode;

· Priority classes used;

· Capability to use Option 1 or Option 2 for signal detection. In cases where the measurement procedures in 3.2.8.5 and 3.2.8.13 are not used:

+ Capability of the LBE to fully comply with requirements in 2.6.2.6 and 2.6.2.7;

+ Capability of the LBE to comply with requirements for

(at 2.6.2.4);

- Special requirements for the minimum quality of the device (at 2.7);

- Maximum quality capability of the device (e.g., maximum throughput, etc.). ||| COT 3.2.2. Frequency

3.2.2.1. Measurement Conditions

Measurements are performed under normal conditions or limit conditions in special cases.

Measurement channels are defined in 3.1.4.

The UUT is configured to operate at the specified RF transmission power level on a single channel.

The UUT has an antenna connector and uses an external antenna or the UUT has an integrated antenna but has a temporary antenna connector measured by direct measurement.

The UUT has an integrated antenna but does not have a temporary antenna connector will be measured by radiation measurement.

3.2.2.2. Direct Measurement Method

- Unmodulated device

UUT with integrated antennas but without temporary antenna connectors will be measured using radiation measurements.

3.2.2.2 Conduction Measurement

Non-modulated Device

UUT is connected to an appropriate frequency meter (frequency counter or spectrum analyzer) and operates in an unmodulated mode.

Record the measured frequency.

- Modulated equipment:

UUT connects to the spectrum analyzer. On the spectrum analyzer, set the Max Hold mode, select the center frequency matching the UUT's frequency.

Record the peak value of the measured power envelope. Decrease the measurement span on the spectrum analyzer and move the Marker towards the positive frequency band until reaching a level of -10 dBc relative to the peak level. Represent the corresponding frequency as f1.

Shift the Marker towards the negative frequency band until reaching a level of -10 dBc relative to the peak level. Represent the corresponding frequency as f2.

The UUT frequency is determined by: (f1+f2)/2

3.2.2.3 Measurement of Radiation

Configure the radiation measurement according to Appendix A with the spectrum analyzer attached to the measuring antenna. The measurement procedure is specified in 3.2.2.2.

3.2.3 Occupied Channel Bandwidth

3.2.3.1 Measurement Conditions

The measurement is performed under normal measurement conditions with the measurement channel and bandwidth specified in 3.1.4.

The measurement is carried out when the device operates in its normal operating mode.

UUT is configured to operate at the RF output power level used during normal operation.

When transmitting simultaneously on multiple adjacent channels, the transmitted signals are considered as a composite signal with the occupied channel bandwidth equal to the sum of the individual component bandwidths. When transmitting simultaneously on multiple non-adjacent channels, each signal is determined separately.

UUT has an antenna connector and uses an external antenna or UUT has an integrated antenna but is temporarily connected to an antenna for the lead-through measurement. In cases where the lead-through measurement is used with smart antennas having multiple transmission chains, the measurement only needs to be performed on one active branch.

UUT with integrated antennas but without temporary antenna connectors will be measured using radiation measurements.

3.2.3.2 Lead-Through Measurement

Step 1: Connect UUT to the spectrum analyzer set up with the following parameters:

- Center Frequency: the frequency of the channel to be measured;

- Resolution Bandwidth: 100 kHz;

- Video Bandwidth: 300 kHz;

- Frequency Span: twice the nominal channel bandwidth (for example, 40 MHz for a 20 MHz channel);

- Sweep Time: > 1 s. For larger nominal bandwidths, the sweep time is increased to ensure it does not affect the RMS value of the signal;

- Detector Mode: RMS;

- Trace Mode: Max Hold.

Step 2: Wait until the sweep image stabilizes.

Step 3:

- Note that the power envelope must be sufficiently larger than the background noise of the spectrum analyzer to prevent noise from affecting the envelope on both sides of the center frequency;

- Use the 99% bandwidth determination feature of the spectrum analyzer to measure the occupied channel bandwidth of UUT and record this value.

Repeat the measurement from Step 1 to Step 3 for other transmitted signals when transmitting simultaneously on non-adjacent channels.

3.2.3.3 Radiation Measurement

The measurement configuration described in Appendix A and the corresponding procedures in Appendix B are implemented.

Perform the measurement according to the method described in 3.2.3.2.

3.2.4 RF Output Power, TPC, and Power Density

3.2.4.1 Measurement Conditions

The UUT has an integrated antenna but does not have a temporary antenna connector will be measured by radiation measurement.

The measurements in this section can be repeated to measure the corresponding indicators:

- Each different TPC range (or receiver output power level for devices not supporting TPC) and each antenna configuration declared by the manufacturer;

- Each transmission mode declared by the manufacturer.

In cases requiring separate function measurement, the device may be configured to transmit continuously or in cycles with an activation duty cycle not less than 10%.

- Unmodulated device

UUT with integrated antennas but without temporary antenna connectors will be measured using radiation measurements.

3.2.4.2 Maximum RF Output Power at Maximum Power Level "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H - Lead-Through Measurement

The measurement is performed under normal and limit measurement conditions.

UUT is configured to achieve the maximum power level within the power range when using TPC or reach the maximum level declared if TPC is not available.

Case 1: Devices capable of continuous transmission or devices capable of transmission in cycles.

In this case, the device operates on a single component band or has the capability to operate on multiple component bands but is designed to operate on a single band and can transmit continuously or in cycles.

Step 1: Skip this step for continuous transmission devices. For cyclic transmission devices:

- The output power of the transmitter must be coupled through a diode hybrid splitter or equivalent. The output of the diode hybrid splitter will be connected to the vertical axis channel of the oscilloscope;

- The use of the diode hybrid splitter and oscilloscope must display information about the cycle and ratio of the transmitted signal;

- The transmission ratio of the transmitter (Tx on / (Tx on + Tx off)) will be recorded in the measurement report.

Step 2:

- The RF output power is measured using a wideband RF power meter with a thermal coupler or equivalent over an integration period sufficiently longer than five times the activation cycle of the transmitter. The measured RF power is represented by A (dBm);

- In the case of lead-through measurement on a smart antenna system with multiple simultaneous transmission branches, the output power of each branch is measured separately to determine the total RF output power of the device being measured;

Step 3:

- The maximum RF output power (EIRP) at the maximum power level is determined from the measured power (dBm), monitoring cycle, antenna gain (dBi), and directional gain (dBi) if this technique is used as follows: "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H + 10 x log(1/ A ), dBm xIf multiple antennas are used, the highest antenna gain value will be used. G (dBi) and directional gain Y (dBi) if this technique is used as follows:

 

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H = A + G + Y + 10 x log(1/x), dBm

(4)

If multiple antennas are used, the value of the highest antenna gain will be applied.

||| The value "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H ||| shall be compared with the limit in Table 2.

Case 2||| : Equipment that does not have the capability to transmit continuously and can only transmit on a single component frequency band.

||| In this case, the equipment may use multiple component frequency bands but at any given time, the transmission signal is only performed within one frequency band. Additionally, the equipment may also transmit simultaneously on multiple component frequency bands but configured to transmit only on one component frequency band.

Step 1:

||| - Sampling the transmitted signal from the equipment using an appropriate fast sensor for the 6 GHz frequency range. Recording the samples to determine the RMS power of the signal.

||| - Setting as follows:

· Sampling rate: ≥ 106 samples/s;

· Measurement period: at least 10 bursts.

Step 2:

||| For equipment using a single transmission branch: connect the power sensor to the transmission port, sample the transmitted signal, and record the measurement results for use in subsequent steps.

||| For equipment using multiple transmission branches:

· Connect the power sensor to each transmission port to measure all ports;

· Control the power sensor sampling to be synchronized with less than 500 ns error;

· For each individual time-domain sample point, aggregate the power from all transmission ports and record the result for use in subsequent steps.

Step 3:

||| Identify the start and end points of each burst in the recorded samples;

· The start and end points are determined correspondingly when the power is at least 30 dB lower than the maximum power in the samples at step 2;

· In cases where there is not a sufficient difference between the samples, the 30 dB threshold value may be reduced to fit the situation;

Step 4:

||| Calculate the RMS power of the burst between the start and end times according to the following expression:

 

 

(5)

in the Field of Teachers and Educational Institution Managers k ||| where n is the number of samples.

||| Represent A (dBm) is the maximum value. "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:||| burst ||| - The RF output power (e.i.r.p.) at the maximum power level

Step 5:

is determined based on the output power "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H (dBm), antenna gain enhancement A (dBi) if this technique is used: G (dBi) and directional gain Y the above determination will be compared with the limit in Table 2 and recorded in the measurement report.

 

 

(6)

||| The value "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H Case 3

||| : Equipment that does not have the capability to transmit continuously but transmits simultaneously on component frequency bands:- The equipment transmits simultaneously on component frequency bands as it cannot be configured to transmit only on one component frequency band;

- Measure the highest power on each component frequency band, then measure the power variation and use the measurement results to determine the RF output power (e.i.r.p.) on each component frequency band.

Step 1: Measure the total peak power in the low component frequency band

- Connect the UUT to the spectrum analyzer and set up the measuring instrument as follows:

· Start Frequency: 5 100 MHz;

· Stop Frequency: 5 400 MHz;

· Resolution Bandwidth: 1 MHz;

· Video Bandwidth: 3 MHz;

· Detector Mode: Peak;

· Trace Mode: Max Hold;

· Sweep Time: Auto

- Ensure that the background noise of the spectrum analyzer is at least 30 dB lower than the peak power envelope. If this level cannot be guaranteed, reduce the power measurement channel bandwidth to near the nominal channel bandwidth (difference around 10%) to minimize the impact of background noise on the measurement results;

- After setting up the measurement parameters, use the power measurement feature to measure the total peak power of the transmitted signals in the frequency band from 5 150 MHz to 5 350 MHz;

- For equipment using multiple transmission branches, the aforementioned measurement procedure is applied to each active branch. The measurement results will be aggregated from all branches.

Step 2: Measure the total peak power in the high component frequency band

- Set the spectrum analyzer: Start Frequency to 5 420 MHz, Stop Frequency to 5 875 MHz;

- After setting up the measurement parameters, use the power measurement feature to measure the total peak power of the transmitted signals in the frequency band from 5 470 MHz to 5 825 MHz;

- After setting up the measurement parameters, use the power measurement feature to measure the total peak power of the transmitted signals in the frequency band from 5 150 MHz to 5 350 MHz;

Step 3: Determine the total peak power:

Step 2: Measure the total peak power in the high component frequency band

- Calculate the total peak power by adding the measurement results from step 1 and step 2;

- Some spectrum analyzers allow simultaneous measurement of peak power on both component frequency bands and automatically calculate the combined result.

Step 4: Measure the average output power

- Sample the transmitted signal of the equipment using a fast sensor suitable for the 6 GHz frequency band. The samples taken are the RMS values of the signal power;

- Set up the measurement configuration:

· Measurement time: sufficiently long to capture at least 10 bursts;

· Sampling rate: ≥ 106 samples/s;

- For the lead measurement for equipment using only one transmission branch: connect the power sensor to the device's transmission port, sample the transmitted signal, and record the results for use in subsequent steps;

- For the lead measurement for equipment using multiple transmission branches:

· Connect the power sensor to each transmission port to perform synchronous measurements on all transmission ports;

· Connect the power sensor to each transmit port to perform synchronous measurements on all transmit ports;

For each sampling point, determine the total power of all measurements on all ports and retain the result for use in subsequent steps;

||| Identify the start and end points of each burst in the recorded samples;

· The start and end points are determined correspondingly when the power is at least 30 dB lower than the maximum power in the samples at step 2;

· In cases where there is not a sufficient difference between the samples, the 30 dB threshold value may be reduced to fit the situation;

||| Calculate the RMS power of the burst between the start and end times according to the following expression:

 

 

(7)

in the Field of Teachers and Educational Institution Managers k ||| where n is the number of samples.

||| The value "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:||| burst The largest value is the average output power to be used in subsequent steps.

Step 5: Determine the power fluctuation ratio

- Using the combined peak power value from Step 3 and the combined average output power value from B4 to calculate the power fluctuation ratio (as the ratio between peak power and average output power).

Step 6:

is determined based on the output power "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H determined for each component band based on the output power variation at Step 5, the peak power on each component band at Steps 1, 2, antenna gain G (dBi) and directional gain Y (dBi) if this technique is used. In cases where multiple antennas are used, the total antenna gain of a branch (G send a text message G + Y) will be used to perform the calculation:

 

 

(8)

- The values "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H will be compared with the limit levels in Table 2.

3.2.4.3 Maximum RF output power at minimum power level "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ - Lead-Through Measurement

Measurement is conducted under normal test conditions and near-limit test conditions on equipment using TPC. The device to be tested must be configured to transmit at the lowest power level within the TPC range.

 

Case 1: Devices capable of continuous transmission or devices capable of transmission in cycles.

In this case, the device operates on a single component band or has the capability to operate on multiple component bands but is designed to operate on a single band and can transmit continuously or in cycles.

Step 1 and Step 2 are similar to Step 1 and Step 2 in 3.2.4.2, except that there is no need for repeated measurement for periodic measurement.

Step 3:

- The RF output power at the lowest power level "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ (e.i.r.p.) is determined from the measured power A ), dBm xIf multiple antennas are used, the highest antenna gain value will be used. G (dBi) and directional gain Y (dBi) if this technique is used as follows:

 

"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ = A + G + Y + 10 x log(1/x), dBm

(9)

If multiple antennas are used, the value of the highest antenna gain will be applied.

||| The value "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ will be compared with the limits in Table 3.

Case 2: Equipment that does not have continuous transmission capability and can only transmit on one component band at a time.

In this case, the equipment may use multiple component bands but at any given time, the signal is transmitted only on one band. Additionally, the equipment may also transmit simultaneously on multiple component bands but is configured to transmit only on one component band.

Step 1, Step 2, Step 3, Step 4 are similar to the corresponding steps in 3.2.4.2.

Step 5:

- The RF output power (e.i.r.p.) at the lowest power level "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:H (dBm), antenna gain enhancement A (dBi) if this technique is used: G (dBi) and directional gain Y the above determination will be compared with the limit in Table 2 and recorded in the measurement report.

 

 

(10)

- The book value of the security is determined according to the Accounting System of the State Bank and the guidance document of the State Bank on the accounting treatment of foreign securities investment operations. "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ as determined above will be compared with the limit levels in Table 3 and recorded in the test report.

||| : Equipment that does not have the capability to transmit continuously but transmits simultaneously on component frequency bands:- The equipment transmits simultaneously on component frequency bands as it cannot be configured to transmit only on one component frequency band;

- Measure the highest power on each component frequency band, then measure the power variation and use the measurement results to determine the RF output power (e.i.r.p.) on each component frequency band.

Step 1: Measure the total peak power in the low component frequency band

- Connect the UUT to the spectrum analyzer and set up the measuring instrument as follows:

· Start Frequency: 5 100 MHz;

· Stop Frequency: 5 400 MHz;

· Resolution Bandwidth: 1 MHz;

· Video Bandwidth: 3 MHz;

· Detector Mode: Peak;

· Trace Mode: Max Hold;

· Sweep Time: Auto

- Ensure that the background noise of the spectrum analyzer is at least 30 dB lower than the peak power envelope. If this level cannot be guaranteed, reduce the power measurement channel bandwidth to near the nominal channel bandwidth (difference around 10%) to minimize the impact of background noise on the measurement results;

- After setting up the measurement parameters, use the power measurement feature to measure the total peak power of the transmitted signals in the frequency band from 5 150 MHz to 5 350 MHz;

- For equipment using multiple transmission branches, the aforementioned measurement procedure is applied to each active branch. The measurement results will be aggregated from all branches.

Step 2: Measure the total peak power in the high component frequency band

- Set the spectrum analyzer: Start Frequency to 5 420 MHz, Stop Frequency to 5 875 MHz;

- After setting up the measurement parameters, use the power measurement feature to measure the total peak power of the transmitted signals in the frequency band from 5 470 MHz to 5 825 MHz;

- After setting up the measurement parameters, use the power measurement feature to measure the total peak power of the transmitted signals in the frequency band from 5 150 MHz to 5 350 MHz;

Step 3: Determine the total peak power:

Step 2: Measure the total peak power in the high component frequency band

- Calculate the total peak power by adding the measurement results from step 1 and step 2;

- Some spectrum analyzers allow simultaneous measurement of peak power on both component frequency bands and automatically calculate the combined result.

Step 4: Measure the average output power

- Sample the transmitted signal of the equipment using a fast sensor suitable for the 6 GHz frequency band. The samples taken are the RMS values of the signal power;

- Sample the transmitted signal of the device using an appropriate fast sensor at the 6 GHz band. The samples taken are the RMS values of the signal power;

· Measurement time: sufficiently long to capture at least 10 bursts;

· Sampling rate: ≥ 106 samples/s;

- For the lead measurement for equipment using only one transmission branch: connect the power sensor to the device's transmission port, sample the transmitted signal, and record the results for use in subsequent steps;

- For the lead measurement for equipment using multiple transmission branches:

· Connect the power sensor to each transmission port to perform synchronous measurements on all transmission ports;

· Connect the power sensor to each transmit port to perform synchronous measurements on all transmit ports;

For each sampling point, determine the total power of all measurements on all ports and retain the result for use in subsequent steps;

||| Identify the start and end points of each burst in the recorded samples;

· The start and end points are determined correspondingly when the power is at least 30 dB lower than the maximum power in the samples at step 2;

· In cases where there is not a sufficient difference between the samples, the 30 dB threshold value may be reduced to fit the situation;

||| Calculate the RMS power of the burst between the start and end times according to the following expression:

 

 

(11)

in the Field of Teachers and Educational Institution Managers k ||| where n is the number of samples.

||| The value "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:||| burst The largest value is the average output power to be used in subsequent steps.

 

Step 5: Determine the power fluctuation ratio

- Using the combined peak power value from Step 3 and the combined average output power value from Step 4 to calculate the power fluctuation ratio (as the ratio between peak power and average output power).

Step 6:

- The RF output power (e.i.r.p.) at the lowest power level "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ determined for each component band based on the output power variation at Step 5, the peak power on each component band at Steps 1, 2, antenna gain G (dBi) and directional gain Y (dBi) if this technique is used. In cases where multiple antennas are used, the total antenna gain of a branch (G send a text message G + Y) will be used to perform the calculation:

 

 

(12)

The values "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:nh cơ will be compared with the limit levels in Table 3.

3.2.4.4 Power density - trace measurement

Testing is performed under normal conditions. The UUT is configured to operate at the smallest defined channel bandwidth and has the highest output power in the TPC range if power control is used, or the declared maximum power if TPC is not used.

 

Case 1: Devices capable of continuous transmission or devices capable of transmission in cycles.

Step 1: Connect the UUT to the spectrum analyzer and set up the measuring instrument as follows:

- Center Frequency: the center frequency of the channel to be measured;

- Resolution Bandwidth: 1 MHz;

- Video Bandwidth: 3 MHz;

- Frequency Span: twice the defined channel bandwidth;

- Detector Mode: Peak;

- Trace Mode: Max Hold;

Step 2: After completing Step 1, find the peak power envelope and record the corresponding frequency;

Step 3: Change the parameters on the spectrum analyzer as follows:

- Center Frequency: the center frequency of the channel to be measured;

- Resolution Bandwidth: 1 MHz;

- Video Bandwidth: 3 MHz;

- Frequency Span: 3 MHz;

- Sweep Time: 1 minute

- Detector Mode: RMS;

- Trace Mode: Max Hold;

Step 4:

- After completing the measurement in Step 3, save the screen using the hold or view function on the spectrum analyzer;

- Determine the peak value point and place a marker corresponding to this point and record the value as the maximum average power density D in the 1 MHz bandwidth;

- If the spectrum analyzer has a power density measurement feature, use this feature to immediately determine the measurement result (graph) of the power spectral density D, dBm/MHz;

- In cases where the device uses smart antennas with simultaneous transmission from multiple antennas, the power spectral density on each antenna branch will be measured separately, then determine the total power spectral density (D) for the entire device to be tested.

Step 5: The maximum power density (e.i.r.p.) is determined based on the value D, cycle xIf multiple antennas are used, the highest antenna gain value will be used. G(dBi), directional gain (if applicable) Y dB according to the following expression. The calculated value will be recorded in the test report. If more than one transmission antenna branch is used, the highest gain among the transmission antennas will be used in the expression.

 

PD= D + G + Y + 10 x log(1/x), dBm/MHz

(13)

Case 2: Equipment that does not have continuous transmission capability and transmits in a fixed periodic manner.

Step 1:

· Start Frequency: 5 100 MHz;

· Start Frequency: the lowest frequency of the component band to be measured (5 150 MHz or 5 470 MHz)

· Stop Frequency: the highest frequency of the component band to be measured (5 350 MHz or 5 825 MHz);

· Resolution Bandwidth: 10 kHz;

· Video Bandwidth: 30 kHz;

· Sweep Points: >20,000 (low component band) or >25,000 (high component band);

· Detector Mode: RMS;

· Sweep Time: Auto

· Sweep Time: 30 seconds;

- For non-continuous signals, wait until the measuring instrument and measurement results stabilize. Save the measurement graph (data) to a file.

Step 2:

- For system measurement using an omnidirectional antenna in operation modes 2 or 3 (see 3.1.5.2), repeat the measurement on each transmit port. For each frequency domain sample point, determine the total measured power from all transmit ports. Record the results corresponding to the measurement points on the frequency domain.

Step 3: Determine the total power of all samples according to the following expression:

 

 

(14)

in the Field of Teachers and Educational Institution Managers k ||| where n is the number of samples.

Step 4:

- Normalize the different power measurement results (dBm) so that the total measured power equals the output RF power (e.i.r.p.) measured in 3.2.4.2:"5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:His the sample index.

 

 

(15)

 

 

(16)

in the Field of Teachers and Educational Institution Managers n Bước 5: Calculate the sum of the power samples

Samplecorr "5. The pre-tax weighted average cost of capital i (%) is determined according to the formula below:) from the starting measurement point (the lowest frequency) to the end of the wideband 1 MHz segments and record the result together with the corresponding sample index. This value is the power density (e.i.r.p.) of the first 1 MHz band.(nStep 6: Shift up one sample and perform the procedure similar to step 2;

- Repeat the steps until the last sample and record the power density measurement results for each 1 MHz segment;

Step 7:

- The highest value among the recorded results is the maximum power density (e.i.r.p.) of the device under test. This value must meet the requirements in Table 2.

3.2.4.5. Radiation Measurement

When performing UUT measurements with directional antennas (including smart antennas and steerable antennas), the device under test is configured to have the highest e.i.r.p. power level on the horizontal plane. This configuration will be saved for future use.

The measurements and corresponding methods are performed as with the lead-through measurements in 3.2.4.2, 3.2.4.3, 3.2.4.4. However, there are some differences to note when performing the measurements as follows:

- Power output measurement:

· When the device under test is in Case 1: ignore the value

used in step 3; G and Y · When the device under test is in Case 2: ignore the value

used in step 5; G and Y · When the device under test is in Case 3: ignore the value

used in step 6; G and Y - Power density measurement: when the device under test is in Case 1, ignore the value

used in step 5. G and Y To measure the maximum and minimum RF output power, the measuring instrument must be a spectrum analyzer or a receiver, not a broadband power sensor. In this case, if the resolution bandwidth (Resolution Bandwidth) of the measuring instrument is smaller than the channel bandwidth occupied by the signal being measured from the UUT, it must be clearly noted in the measurement report.

3.2.5. Unwanted Emission Outside the 5 GHz Band

3.2.5.1. Measurement Conditions

The measurements specified in 2.4.1 are carried out under normal measurement conditions when using the channels defined in 3.1.4.

The device under test is configured to operate in the condition causing the greatest unwanted emissions outside the 5 GHz band.

If supported, the UUT must be set to continuously transmit throughout the measurement period. If continuous transmission is not supported, the UUT is configured to transmit at the highest possible duty cycle.

Unwanted emission measurements are represented by one of the following quantities:

- Power on a dedicated load (lead-through measurement) and radiated power (e.r.p. or e.i.r.p. as in 2.4.1) when there is radiation from the casing or physical structure of the device;

- Radiated power (e.r.p. or e.i.r.p. as in 2.4.1) when there is radiation from the casing and antenna.

3.2.5.2. Lead-through Measurement - Pre-scan Procedure

The UUT is connected to a spectrum analyzer capable of measuring RF power. A pre-scan procedure is performed to determine the potential for unwanted emissions from the UUT.

- The sensitivity of the spectrum analyzer is checked and set to ensure that the noise floor is at least 12 dB lower than the level specified in Table 4.

Step 1:

- Identify unwanted emissions in the range from 30 MHz to 1,000 MHz;

Step 2:

- Set the parameters on the spectrum analyzer as follows:

· Resolution bandwidth: 100 kHz

· Video bandwidth: 300 kHz

· Detector mode: Peak

· Trace mode: Max Hold

· Sweep Points: ≥ 9,700 (if the spectrum analyzer does not support this setting, the frequency band can be segmented). If the spectrum analyzer has the capability to sweep twice the minimum required number of points, the frequency adjustment to find the maximum emission in step 1 of 3.2.5.3 can be skipped;

· Sweep Time: if not continuous transmission, the sweep time must be long enough so that for each 100 kHz frequency resolution band, the measurement time is at least twice the duration of consecutive UUT transmissions;

- Wait for the displayed results to stabilize. Identify all emissions within a 6 dB difference from the level specified in Table 4 to perform the measurement in 3.2.5.3.

- Identify unwanted emissions in the range from 1 GHz to 26 GHz;

Step 3:

· Resolution bandwidth: 1 MHz

· Resolution bandwidth: 100 kHz

· Video bandwidth: 3 MHz

· Sweep Points: ≥ 25,000 (if the spectrum analyzer does not support this setting, the frequency band can be segmented). If the spectrum analyzer has the capability to sweep twice the minimum required number of points, the frequency adjustment to find the maximum emission in step 1 of 3.2.5.3 can be skipped;

· Trace mode: Max Hold

· Sweep Points: ≥ 9,700 (if the spectrum analyzer does not support this setting, the frequency band can be segmented). If the spectrum analyzer has the capability to sweep twice the minimum required number of points, the frequency adjustment to find the maximum emission in step 1 of 3.2.5.3 can be skipped;

· Sweep Points: ≥ 25,000 (if the spectrum analyzer does not support this setting, the frequency range can be segmented). If the spectrum analyzer has the capability to sweep twice the minimum required number of points, frequency fine-tuning to find the maximum emission in step 1 of 3.2.5.3 can be omitted;

Sweep Time: if not continuously transmitted, the sweep time must be sufficient to ensure that within each 1 MHz resolution step across the frequency band, the measurement duration is at least twice the continuous transmission period of the UUT;

- Wait for the displayed results to stabilize. Determine all emissions within a 6 dB deviation range from the specified level in Table 4 for the measurement in 3.2.5.3.

3.2.5.3 Measurement Procedure - Post-scan Emission Measurement

The limits on unwanted emissions of the transmitter in 2.4.1 apply to average power levels.

The steps in this section are used to accurately identify individual emissions detected through the pre-scan procedure.

Depending on whether the signal is continuous or non-continuous, the following measurements are performed:

- Continuous Signal: the measuring instrument uses the RMS separation mode on spectrum analysis;

- Non-Continuous Signal: the measurement is only conducted when there is a transmission signal during the burst.

Step 1:

- Set the parameters on the spectrum analyzer as follows:

· Center Frequency: the emission frequency determined in the pre-scan procedure;

· Resolution Bandwidth: 100 kHz (< 1 GHz), 1 MHz (≥ 1 GHz);

· Video Bandwidth: 300 kHz (< 1 GHz), 3 MHz (≥ 1 GHz);

· Frequency Span: 0 Hz;

· Sweep Mode: Single Sweep;

· Sweep Time: sufficient to contain a burst transmission. Additional measurements may be required to determine the burst interval. If the device requires continuous transmission measurement, Sweep Time is set to 30 ms;

· Sweep Point: equal to the sweep time value in milliseconds (but not exceeding 30,000);

· Trigger: observed via image or manually executed;

· Detector: RMS;

· Trace Mode: Clear/Write;

- Adjust the center frequency of the spectrum analyzer to obtain the maximum emission during the burst transmission. This step can be skipped if the spectrum analyzer can scan with at least twice the number of points compared to the required points in the pre-scan procedure steps.

Step 2:

- Adjust the signal capture level to select the emission with the highest level;

- Set the window to coincide with the start and end of the burst transmission to measure the RMS power in the time domain. If the unwanted emission caused by continuous signals needs to be measured, the measurement window must be set to coincide with the start and end of each sweep;

- Select and record the measured RMS power value, then compare it with the limit in Table 4.

The measurement procedures in this section are carried out for each emission identified through the pre-scan procedure in 3.2.5.2.

In cases where the device uses a smart antenna with multiple transmission branches, the measurement is performed on each active transmission branch. The measurement results are used to compare against one of the two options below:

- Option 1: the measurement results on each transmission branch at intervals of 1 MHz are summed and compared with the limit in Table 4;

- Option 2: the measurement results on each transmission branch are compared with a lower limit of 10 x log(number of simultaneously active transmission branches) than the limit in Table 4.Tc Qu) (Tc Qu (where n is the number of simultaneously active transmit branches) compared to the limit in Table 4.

3.2.5.4 Radiation Measurement

The measurement configuration is defined in Appendix A by connecting the spectrum analyzer to the measurement antenna, then performing the measurement according to the procedure in 3.2.5.2 and 3.2.5.3.

3.2.6 Unwanted Emissions in the 5 GHz RLAN Band

The measurement criteria in 2.4.2 are performed under normal measurement conditions using the channels defined in 3.1.4.

The device under test (UUT) is configured to operate in a condition causing the greatest unwanted emissions in the 5 GHz RLAN band.

For UUTs without integrated antennas or with integrated antennas but with temporary antenna ports, direct measurement should be prioritized. Conversely, if the UUT has integrated antennas but no temporary antenna port, radiation measurement should be performed.

If the UUT uses a smart antenna system with multiple simultaneous transmission chains, the measurements are performed on one of the transmission chains.

3.2.6.1 Direct Measurement

Case 1: The UUT is capable of continuous transmission

The measurement is used when the UUT is configured for continuous transmission.

Step 1: Determine the reference average power level

- Set the parameters on the spectrum analyzer as follows:

· Video bandwidth: 3 MHz

· Video bandwidth: 30 kHz

· Trace mode: Max Hold

· Trace mode: Video Average

· Sweep Time: Coupled;

· Center Frequency: the center frequency of the channel being transmitted by the UUT;

· Span: 2 x the defined channel bandwidth.

- Use a marker to find the highest average power level in the measured power envelope. The determined level will be considered the reference level.

Step 2: Determine the relative average power level

- Adjust the frequency range of the spectrum analyzer so that the measurement can be performed in the frequency bands from 5150 MHz to 5350 MHz and 5470 MHz to 5825 MHz. Other parameters on the spectrum analyzer remain unchanged;

- Compare the measured relative power levels (the reference level determined in step 1) with the limits specified in 2.4.2.

Case 2The UUT does not have the capability to transmit continuously

Step 1: Determine the reference average power level

- Set the parameters on the spectrum analyzer as follows:

· Video bandwidth: 3 MHz

· Video bandwidth: 30 kHz

·           Detector mode: RMS

· Sweep Points: ≥ 9,700 (if the spectrum analyzer does not support this setting, the frequency band can be segmented). If the spectrum analyzer has the capability to sweep twice the minimum required number of points, the frequency adjustment to find the maximum emission in step 1 of 3.2.5.3 can be skipped;

·           Sweep Time: ≥ 1 minute;

· Center Frequency: the center frequency of the channel being transmitted by the UUT;

· Span: 2 x the defined channel bandwidth.

- Use a marker to find the highest average power level in the measured power envelope. The determined level will be considered the reference level.

Step 2: Determine the relative average power level

- Adjust the frequency range of the spectrum analyzer so that the measurement can be performed in the frequency bands from 5150 MHz to 5350 MHz and 5470 MHz to 5825 MHz. Other parameters on the spectrum analyzer remain unchanged;

- Compare the measured relative power levels (the reference level determined in step 1) with the limits specified in 2.4.2.

3.2.6.2.        Radiation measurement

The radiation measurement uses the measurement configuration in Appendix A and the spectrum analyzer connected to the measurement antenna. The measurement procedure is similar to the measurement procedure in 3.2.6.1.

3.2.7.      Receiver spurious emissions

3.2.7.1.        Measurement conditions

Receiver spurious emissions are measured under normal operating conditions of the equipment using the channels defined in 3.1.4.

For equipment that has multiple operating modes (see 3.1.5.2), measurements need not be performed with all modes.

Receiver spurious emissions may be measured and represented by at least one of the following quantities:

-      Power on dedicated load (direct measurement) and radiated power (e.r.p. or e.i.r.p. as in 2.4.1) when there is radiation from the device's housing or physical structure;

3.2.5.2. Lead-through Measurement - Pre-scan Procedure

Measurements in this section are carried out when the receiver is configured to operate in continuous reception mode or non-transmitting mode.

3.2.7.2.        Direct measurement - Pre-scan verification procedure

The pre-scan verification procedure is conducted to determine the potential for receiver spurious emissions of the UUT.

Step 1:

-      The sensitivity of the spectrum analyzer is checked and set to ensure that the background noise is at least 12 dB lower than the level specified in Table 5.

Step 2:

- Set the parameters on the spectrum analyzer as follows:

· Resolution bandwidth: 100 kHz

· Video bandwidth: 300 kHz

· Detector mode: Peak

· Trace mode: Max Hold

· Sweep Points: ≥ 9,700 (if the spectrum analyzer does not support this setting, the frequency band can be segmented). If the spectrum analyzer has the capability to sweep twice the minimum required number of points, the frequency adjustment to find the maximum emission in step 1 of 3.2.5.3 can be skipped;

·           Sweep Points: ≥ 9,700 (if the spectrum analyzer does not support this setting, the frequency band to be measured can be segmented). If the spectrum analyzer has the ability to sweep twice the minimum required number of points, the frequency adjustment in Step 1 of 3.2.7.3 can be skipped;

·           Sweep Time: Auto;

-      Wait until the displayed result stabilizes. Identify all emissions within a 6 dB range of the level specified in Table 5 to perform the measurement in 3.2.7.3.

Step 3:

· Resolution bandwidth: 1 MHz

· Resolution bandwidth: 100 kHz

· Video bandwidth: 3 MHz

· Sweep Points: ≥ 25,000 (if the spectrum analyzer does not support this setting, the frequency band can be segmented). If the spectrum analyzer has the capability to sweep twice the minimum required number of points, the frequency adjustment to find the maximum emission in step 1 of 3.2.5.3 can be skipped;

· Trace mode: Max Hold

· Sweep Points: ≥ 9,700 (if the spectrum analyzer does not support this setting, the frequency band can be segmented). If the spectrum analyzer has the capability to sweep twice the minimum required number of points, the frequency adjustment to find the maximum emission in step 1 of 3.2.5.3 can be skipped;

·           Sweep Points: ≥ 25,000 (if the spectrum analyzer does not support this setting, the frequency band to be measured can be segmented). If the spectrum analyzer has the ability to sweep twice the minimum required number of points, the frequency adjustment in Step 1 of 3.2.7.3 can be skipped;

·           Sweep Time: Auto;

-      Wait until the displayed result stabilizes. Identify all emissions within a 6 dB range of the level specified in Table 5 to perform the measurement in 3.2.7.3.

3.2.7.3.        Direct measurement - Post-scan emission measurement procedure

The limits for receiver spurious emissions in 2.5.2 apply to average power levels.

The steps in this section are used to accurately identify individual emissions detected through the pre-scan verification procedure. The spectrum analyzer must have the capability to measure power in the time domain.

Step 1:

- Set the parameters on the spectrum analyzer as follows:

·           Measurement Mode: Time Domain Power

·           Center Frequency: the spurious emission frequency determined in the pre-scan verification procedure;

· Resolution Bandwidth: 100 kHz (< 1 GHz), 1 MHz (≥ 1 GHz);

· Video Bandwidth: 300 kHz (< 1 GHz), 3 MHz (≥ 1 GHz);

· Frequency Span: 0 Hz;

· Sweep Mode: Single Sweep;

·           Sweep Time: 30 ms;

·           Sweep Point: ≥ 30,000;

· Trigger: observed via image or manually executed;

· Detector: RMS;

-      Adjust the center frequency of the spectrum analyzer to capture the largest emission in the burst emission. This step can be skipped if the spectrum analyzer can sweep more than twice the number of points required in the pre-scan verification procedure steps.

Step 2:

-      Set the window to match the start and end of the highest burst emission and record the measured power value in this time window;

-      If the spurious emission to be measured appears continuously, the measurement window needs to be set to coincide with the start and end of each scan.

- Select and record the measured RMS power value, then compare it with the limit in Table 4.

Step 3:

-      In the case where the device uses a smart antenna with multiple receiving branches, the measurement is performed on each active receiving branch;

-      Determine the total measured power in the measurement window across all receiving branches.

Step 4:

The value determined in Step 3 will be compared to the limit in Table 5.

3.2.7.4.        Radiated measurement

The radiated measurement uses the measurement configuration in Appendix A and the spectrum analyzer connected to the measurement antenna. The measurement procedure is similar to the measurement procedures in 3.2.7.2 and 3.2.7.3.

3.2.8.      Adaptive access mechanism

The measurements in this section are carried out under normal measurement conditions. The channels used for measurement comply with the requirements in 3.1.4. The equipment to be measured is configured to operate at the highest output power level.

3.2.8.1.        FBE Device - Additional Measurement Conditions

The manufacturer must declare the UUT as an initiating device and/or responding device.

The manufacturer must declare the fixed frame period (FFP) intervals used by the FBE device.

All measurements must be performed in the time domain with a resolution less than 1 ms.

The measuring equipment must be able to track the UUT throughout a process of at least 250 ms with the aforementioned time resolution. If data is recorded in separate segments, the fixed frame period (FFP) intervals will be separated from each segment. The combination of all FFP intervals will be analyzed as in 3.2.8.5.

3.2.8.2.        FBE Device - Initiating Direct Measurement

The measurement configuration is illustrated in Figure 5.

 

Traffic source

||| Unit under test

Divider/

Adder

Spectrum analyzer

Signal generator

Companion device

Divider/

Adder

 

Figure 5 - FBE measurement configuration - Direct measurement

Step 1:

-      The UUT is connected to related devices during the measurement process. The signal generator, spectrum analyzer, UUT, traffic source, and related devices are connected as shown in Figure 5, where the noise generator is turned off. The spectrum analyzer is used to monitor the UUT's transmitted signal under the influence of noise. The traffic source may be part of the UUT's structure.

- The received signal level (desired signal) at the UUT must be sufficient to ensure and maintain a reliable connection during measurement. The typical received signal level value in most cases is -50 dBm/MHz.

- Set the following parameters on the spectrum analyzer:

· RBW: ≥ channel bandwidth (or the highest value of the spectrum analysis if the above requirement is not met);

· VBW: ≥ RBW (or the highest value of the spectrum analysis if the above requirement is not met);

· Detector Mode: RMS;

· Center Frequency: operating channel frequency of the UUT;

· Span: 0 Hz;

· Sweep Time: > 2 x ||| COT;

· Trace Mode: Clear/Write;

· Trigger Mode: Video or RF/IF Power.

Step 2:

- Configure the traffic source so that the UUT's buffer ensures there is always data queued for transmission (called the ready-to-transmit condition) to the related device. If this configuration cannot be achieved, the UUT must be configured with the maximum time within the fixed frame period FFP. ||| COT - To avoid the impact of reverse traffic flow on the measurement results, the traffic source used must be unidirectional.

- To avoid the impact of reverse traffic flow on the measurement results, the traffic source used must be unidirectional.

3.2.8.3. FBE Device - Conducted Measurement - Procedure to Confirm the Ability to Detect Other RLAN Signals on the Operating Channel in Single-Channel Mode

Step 1: Establish Connection

- The UUT is configured to operate in single-channel mode (using only one operating channel).

Step 2: Connect Interference Signal

- One of the three interference signals described in B.7 is introduced into the UUT's operating channel. The interference signal bandwidth includes the entire operating channel. The interference signal level at the UUT input equals the level defined in 2.6.1. ED Threshold Level Step 3: Confirm Device Response to Interference Signal

- A spectrum analyzer is used to monitor the UUT's transmitted signal on the operating channel after introducing the interference signal. The spectrum analyzer needs to scan to detect when the interference signal is present.

- Confirm the following requirements according to the procedure in 3.2.8.6:

· The UUT does not transmit on the operating channel during the next fixed frame period FFP following the first Clear Channel Assessment (CCA) procedure after the interference signal is introduced. The UUT may transmit short control signaling (Short Control Signaling Transmission) on the operating channel as subsequent requirements;

· In addition to the short control signaling, the UUT must not transmit other signals when the interference signal is present;· The short control signaling must meet the requirements in 2.6.3. Confirming the response to the short control signaling may require changes to the parameters on the spectrum analyzer. on operational channels as follows;

· In addition to short control signals, UUT shall not emit other signals when there is interference;

· Short control signals must satisfy the requirements in 2.6.3. Confirmation of compliance with short control signals may require changes to the spectrum analyzer settings;

-      Để xác nhận UUT không phát tín hiệu thường (ngoài báo hiệu ngắn) khi có nhiễu, thời gian giám sát phải bằng 60 s hoặc lâu hơn nếu cần phân đoạn thực hiện đo để đáp ứng yêu cầu về độ phân giải;

-      Khi hoàn thành phép đo và loại bỏ tín hiệu nhiễu, UUT có thể được bắt đầu phát trở lại trên kênh vận hành nhưng không cần xác nhận thêm các yêu cầu khác.

Bước 4:

Thực hiện lại bước 2 và bước 3 đối với các tín hiệu nhiễu khác trong B.7.

3.2.8.4.    Thiết bị FBE - Phép đo dẫn - Thủ tục xác nhận khả năng phát hiện tín hiệu RLAN khác trong trường hợp sử dụng nhiều kênh vận hành

Bước 1: Thiết lập kết nối

-      UUT được cấu hình để hoạt động từ 2 đến 6 kênh vận hành 20 MHz liên tiếp. Số lượng kênh được sử dụng được ghi lại trong Báo cáo đo;

-      Xác nhận UUT đã bắt đầu phát trên các kênh vận hành

Bước 2: Chèn tín hiệu nhiễu

-      Nhiễu (xem B.1.1) được bật;

-      Tần số và băng thông của nhiễu phải đảm bảo để chứa tất cả các kênh vận hành được sử dụng. Ngoài ra, bài đo có thể thực hiện bằng các lần lượt đưa nhiễu với tần số và băng thông đủ để chứa duy nhất từng kênh vận hành;

-      Mức tín hiệu nhiễu tại đầu vào UUT phải bằng mức ED Threshold Level (TL) định nghĩa trong 2.6.1.

Bước 3: Xác nhận đáp ứng của thiết bị với tín hiệu nhiễu

-      Phân tích phổ được sử dụng để giám sát tín hiệu phát của UUT trên kênh vận hành sau khi có tín hiệu nhiễu đưa vào. Phân tích phổ cần quét để phát hiện khi có tín hiệu nhiễu;

-      Xác nhận các yêu cầu sau theo thủ tục trong 3.2.8.6:

·           UUT không phát trên tất cả kênh vận hành thiết lập ở bước 1 có nhiễu trong khoảng thời gian chu kỳ khung cố định FFP tiếp theo thủ tục CCA đầu tiên sau khi tín hiệu nhiễu được phát hiện. UUT được phép phát tín hiệu điều khiển ngắn trên kênh vận hành như các yêu cầu tiếp theo;

·           Ngoài tín hiệu điều khiển ngắn, UUT không được phát tín hiệu khác khi có tín hiệu nhiễu;

·           Tín hiệu điều khiển ngắn phải thỏa mãn yêu cầu trong 2.6.3. Việc xác nhận đáp ứng đối với tín hiệu điều khiển ngắn có thể yêu cầu thay đổi thông số trên phân tích phổ;

-      Để xác nhận UUT không phát tín hiệu thường (ngoài báo hiệu ngắn) khi có nhiễu, thời gian giám sát phải bằng 60 s hoặc lâu hơn nếu cần phân đoạn thực hiện đo để đáp ứng yêu cầu về độ phân giải;

-      Khi hoàn thành phép đo và loại bỏ tín hiệu nhiễu, UUT có thể được bắt đầu phát trở lại trên kênh vận hành nhưng không cần xác nhận thêm các yêu cầu khác.

3.2.8.5.        Thiết bị FBE - Phép đo dẫn - Cơ chế truy nhập kênh

Mục này quy định thủ tục đo kiểm để xác nhận phù hợp đối với tham số COT và khoảng thời gian rỗi (Idle Period) được sử dụng trong cơ chế truy nhập kênh.

Bước 1: tương tự bước 1 trong 3.2.8.2.

Bước 2: tương tự bước 2 trong 3.2.8.2.

Bước 3: Ghi tham số phát.

-      Ghi thời điểm bắt đầu và khoảng thời gian phát, thời điểm bắt đầu và thời gian nghỉ giữa các lần phát trên kênh vận hành;

-      Biểu diễn tx là thời điểm UUT bắt đầu, dx là khoảng thời gian kênh vận hành được sử dụng. Biểu diễn iy là thời điểm bắt đầu, gylà khoảng thời gian kênh vận hành không được sử dụng Hình 6 biểu diễn các thông số này.

Bước 4: Đo khoảng thời gian không sử dụng (Un-Occupied Period) COT

-      Khoảng thời gian COT được định nghĩa bằng  với tc<th. nếu trong khoảng thời gian , tất các các khoảng thời gian gy kênh vận hành không có tín hiệu phát đều không lớn hơn 16 ms. Như được định nghĩa trong 2.6.1, trong mỗi COT có thể có một hoặc nhiều hơn lần UUT phát;

-      Sử dụng các giá trị ghi được ở bước 3, có thể xác định được các giá trị của các khoảng thời gian COT và các khoảng thời gian không sử dụng. Khoảng thời gian không sử dụng là khoảng thời gian giữa các lần phát khác nhau của UUT với giá trị không lớn hơn 18 ms. Các khoảng thời gian lớn hơn giá trị này được coi như nằm trong COT.  

Bước 5: Xác định chu kỳ khung cố định FFP

-      Dựa trên các kết quả đo ở bước 4 và khai báo chu kỳ khung cố định FFP của UUT, xác định thời điểm bắt đầu và kết thúc của từng FFP;

-      Khoảng thời gian không sử dụng ngay trước thời điểm bắt đầu của chu kỳ khung cố định FFP được gọi là khoảng thời gian rỗi của khoảng thời gian FFP trước đó như được định nghĩa trong 2.6.1.

 

 

Ie      ge >16ms Kênh chiếm dụng ogồm nhiều đường truyền  gh >16ms

                          Thời gian kênh chiếm dụng oy là (th+d- te)

 

Ie  t0            t0+d0             te      te+de tf        tf +dtg     tg+dg   th               th+dh                        t

Ie  ie          ie+ge      iif +gf          ig    ig+gg    ig       ig+gg             ih                          ih + g

 

Hình 6 -Tiến trình trên UUT

Bước 6: Xác nhận thỏa mãn yêu cầu

-      Sử dụng kết quả trong bước 5 để đánh giá sự phù hợp của các tham số xác định được với yêu cầu về COT lớn nhất và khoảng thời gian rỗi nhỏ nhất trong từng chu kỳ khung cố định FFP được sử dụng.

3.2.8.6.        Thiết bị FBE - Phép đo dẫn - Thủ tục đo việc sử dụng kênh/tần số

Mục này đưa ra thủ tục đo chung để xác định có tín hiệu phát trên kênh vận hành đang đo hay không. Thủ tục này chỉ được sử dụng như một phần của thủ tục ở các mục đã nói ở trên.

Bước 1:

-      Đặt thông số máy phân tích phổ như sau:

·           Centre Frequency: Tần số trung tâm của kênh đang được kiểm tra;

·           Frequency Span: 0 Hz

·           RBW: khoảng 50 % băng thông kênh chiếm dụng (nếu không hỗ trợ đến mức này, sử dụng RBW cao nhất của máy);

·           VBW: ≥ RBW (nếu phân tích phổ không hỗ trợ, lựa chọn VBW lớn nhất có thể được thiết lập);

·           Detector Mode: RMS;

·           Sweep Time: > 2 x COT;

·           Sweep Points: ít nhất một điểm trong 1 ms;

·           Trace Mode: Clear/Write;

·           Trigger: Video hoặc RF/IF Power.

Bước 2:

-      Lưu dữ liệu đo vào file để thực hiện phân tích bằng máy tính bằng phần mềm thích hợp.

Bước 3:

-      Xác định các điểm dữ liệu cần phân tích bằng cách sử dụng ngưỡng phát hiện;

-      Đếm số điểm dữ liệu liên tiếp được xác định là kết quả của một lần truyền trên kênh đang được đánh giá và nhân số này với chênh lệch thời gian giữa hai điểm dữ liệu liên tiếp. Lặp lại việc này trên toàn bộ cửa sổ đo;

-      Khi đo các khoảng thời gian rỗi hoặc khoảng lặng, đếm số điểm dữ liệu liên tiếp từ một khoảng dừng phát trên kênh được đánh giá và nhân số điểm này với khoảng thời gian giữa hai điểm dữ liệu liên tiếp. Lặp lại việc này trên toàn bộ cửa sổ đo.

3.2.8.7.        Thiết bị FBE - Phép đo bức xạ

Công suất đầu ra của bộ tạo tín hiệu nhiễu phải thích hợp để công suất đầu vào ăng ten của UUT bằng mức ED Threshold Level trong 2.6.1.

Khi thực hiện đo kiểm bằng phương pháp bức xạ trên UUT có ăng ten định hướng (bao gồm ăng ten thông minh và ăng ten có khả năng điều hướng), đường kết nối giữa UUT với thiết bị đi kèm và tín hiệu radar được tạo ra phải được sắp xếp trùng với hướng bức xạ lớn nhất của ăng ten được UUT sử dụng.

Cấu hình đo trong Phụ lục A và thủ tục đo liên quan trong Phụ lục B sẽ được sử dụng trong quá trình đo UUT. Thủ tục đo bức xạ cũng tương tự như đối với đo dẫn.

3.2.8.8.        Thiết bị LBE - Điều kiện đo bổ sung

UUT có khả năng hoạt động ở chế độ thiết bị giám sát và thiết bị được giám sát (Supervising và Supervised) phải được đo ở cả hai chế độ.

Nhà sản xuất phải khai báo các thông tin sau:

-      Khả năng UUT sử dụng Chú thích 1 của Bảng 7hoặc Chú thích 1 của Bảng 8;

-      Khả năng sử dụng Chú thích 2 của Bảng 7nếu UUT là thiết bị giám sát và thiết bị được giám sát;

-      Dạng thiết bị của UUT là thiết bị khởi tạo và/hoặc thiết bị đáp ứng;

-      Mức chất lượng cao nhất theo lý thuyết của UUT;

-      Các Lớp ưu tiên (Priority Class) được UUT sử dụng.

Tất cả phép đo cần được thực hiện với độ phân giải thời gian không vượt quá 1 ms.

Thiết bị đo phải có khả năng giám sát, theo dõi UUT trong ít nhất 10 000 khoảng thời gian COT với độ phân giải theo yêu cầu nói trên. Dữ liệu lưu lại có thể được phân đoạn. Khi đó, các khoảng thời gian COT sẽ được tách ra từ các phân đoạn dữ liệu được lưu. Việc phân tích, đánh giá COT được thực hiện theo thủ tục 3.2.8.11.

Lớp ưu tiên sử dụng trong phép đo được lựa chọn như sau:

-      Nếu có Lớp ưu tiên 2 (và có thể lớp ưu tiên khác), UUT phải được đo để đánh giá so với các yêu cầu tương ứng Lớp ưu tiên 2 như được quy định trong Bảng 7, Bảng 8;

-      Nếu không sử dụng Lớp ưu tiên 2 nhưng có Lớp ưu tiên 1 (hoặc các lớp ưu tiên khác), UUT phải được đo để đánh giá so với các yêu cầu tương ứng Lớp ưu tiên 1 như được quy định trong Bảng 1, Bảng 7, Bảng 8;

-      Nếu không sử dụng Lớp ưu tiên 1, 2 nhưng có Lớp ưu tiên 3 (hoặc 4), UUT phải được đo để đánh giá so với các yêu cầu tương ứng Lớp ưu tiên 3 như được quy định trong Bảng 1, Bảng 7, Bảng 8;

-      Nếu chỉ sử dụng Lớp ưu tiên 4, UUT phải được đo để đánh giá so với các yêu cầu tương ứng Lớp ưu tiên 4 như được quy định trong Bảng 1, Bảng 7, Bảng 8;

3.2.8.9.        Thiết bị LBE - Khởi tạo phép đo dẫn

Hình 7 biểu diễn ví dụ sơ đồ đo thiết bị bằng phép đo dẫn.

 

Bộ chia/

cộng

UUT

Nguồn lưu lượng

Bộ chia/

cộng

Thiết bị đồng hành

Máy phát tín hiệu

Máy phân tích phổ

 

Hình 7 - Sơ đồ đo thiết bị LBE bằng phép đo dẫn

 

Việc đánh giá khả năng thích nghi của thiết bị được thực hiện với các thủ tục dưới đây.

Bước 1:

-      UUT nối với thiết bị liên quan trong quá trình đo. Máy tạo tín hiệu, máy phân tích phổ, UUT, nguồn lưu lượng và các thiết bị liên quan được kết nối như trong Hình 7, trong đó bộ tạo nhiễu được tắt. Máy phân tích phổ được sử dụng để giám sát tín hiệu phát của UUT dưới ảnh hưởng của nhiễu. Nguồn lưu lượng có thể là một phần trong cấu trúc của UUT;

-      Mức tín hiệu thu (tín hiệu mong muốn) tại UUT phải đủ để đảm bảo và duy trì kết nối tin cậy trong quá trình đo. Giá trị mức tín hiệu thu điển hình trong phần lớn các trường hợp là -50 dBm/MHz.

-      Cài đặt các thông số sau trên phân tích phổ:

·           RBW: ≥ băng thông kênh chiếm dụng (hoặc giá trị cao nhất của phân tích phổ nếu không đảm bảo yêu cầu trên);

·           VBW: ≥ 3 x RBW (hoặc giá trị cao nhất của phân tích phổ nếu không đảm bảo yêu cầu trên);

·           Detector Mode: RMS;

·           Centre Frequency: tần số kênh vận hành của UUT;

·           Span: 0 Hz;

·           Sweep Time: > 2 x COT;

·           Trace Mode: Clear/Write;

·           Trigger Mode: Video hoặc RF/IF Power.

Bước 2:

-      Cấu hình nguồn lưu lượng sao cho bộ nhớ đệm của UUT đảm bảo luôn có dữ liệu được xếp hàng để phát (gọi là điều kiện phát đệm sẵn sàng) đến thiết bị liên quan. Nếu không thể cấu hình theo yêu cầu này, UUT phải được cấu hình để có thời gian COT lớn nhất trong khoảng thời gian chu kỳ khung cố định FFP;

-       Để tránh ảnh hưởng của hiện tượng đảo chiều lưu lượng đến kết quả đo, nguồn lưu lượng được sử dụng là nguồn có chiều duy nhất.

3.2.8.10.     Thiết bị LBE - Phép đo dẫn - Thủ tục xác nhận khả năng phát hiện tín hiệu RLAN khác trên kênh vận hành ở chế độ đơn kênh

Bước 1: Thiết lập kết nối

-      UUT được cấu hình để hoạt động ở chế độ đơn kênh (sử dụng duy nhất 1 kênh vận hành);

Bước 2: Kết nối tín hiệu gây nhiễu

-      Một trong 3 tín hiệu gây nhiễu như mô tả trong B.7 được đưa vào kênh vận hành của UUT. Băng thông của tín hiệu nhiễu chứa cả kênh vận hành. Mức tín hiệu nhiễu tại đầu vào UUT bằng mức ED Threshold Level(TL) định nghĩa trong 2.6.2.

Bước 3: Xác nhận đáp ứng của thiết bị với tín hiệu nhiễu

-      Phân tích phổ được sử dụng để giám sát tín hiệu phát của UUT trên kênh vận hành sau khi có tín hiệu nhiễu đưa vào. Phân tích phổ cần quét để phát hiện khi có tín hiệu nhiễu;

-      Xác nhận các yêu cầu sau theo thủ tục trong 3.2.8.17:

·           UUT dừng phát trên kênh vận hành trong khoảng thời gian bằng giá trị lớn nhất của COT tương ứng với mức Lớp ưu tiên đang được sử dụng khi đo (xem Bảng 7, Bảng 8). UUT được phép phát tín hiệu điều khiển ngắn trên kênh vận hành như các yêu cầu tiếp theo;

·           Ngoài tín hiệu điều khiển ngắn, UUT không được phát tín hiệu khác khi có tín hiệu nhiễu;

·           Tín hiệu điều khiển ngắn phải thỏa mãn yêu cầu trong 2.6.3. Việc xác nhận đáp ứng đối với tín hiệu điều khiển ngắn có thể yêu cầu thay đổi thông số trên phân tích phổ;

-      Để xác nhận UUT không phát tín hiệu thường (ngoài báo hiệu ngắn) khi có nhiễu, thời gian giám sát phải bằng 60 s hoặc lâu hơn nếu cần phân đoạn thực hiện đo để đáp ứng yêu cầu về độ phân giải;

-      Khi hoàn thành phép đo và loại bỏ tín hiệu nhiễu, UUT có thể được bắt đầu phát trở lại trên kênh vận hành nhưng không cần xác nhận thêm các yêu cầu khác.

Bước 4:

Thực hiện lại bước 2 và bước 3 đối với các tín hiệu nhiễu khác trong B.7.

3.2.8.11.     Thiết bị LBE - Phép đo dẫn - Thủ tục xác nhận khả năng phát hiện tín hiệu RLAN khác trong trường hợp sử dụng nhiều kênh vận hành theo Tùy chọn 1

Bước 1: Thiết lập kết nối

-      UUT được cấu hình để hoạt động từ 2 đến 6 kênh vận hành 20 MHz liên tiếp. Số lượng kênh được sử dụng được ghi lại trong Báo cáo đo;

-      Xác nhận UUT đã bắt đầu phát trên các kênh vận hành

Bước 2: Chèn tín hiệu nhiễu

-      Nhiễu (xem B.1.1) được bật;

-      Tần số và băng thông của nhiễu phải đảm bảo để chứa tất cả các kênh vận hành được sử dụng. Ngoài ra, bài đo có thể thực hiện bằng các lần lượt đưa nhiễu với tần số và băng thông đủ để chứa duy nhất từng kênh vận hành;

-      Mức tín hiệu nhiễu tại đầu vào UUT phải bằng mức ED Threshold Level (TL) định nghĩa trong 2.6.2.

Bước 3: Xác nhận đáp ứng của thiết bị với tín hiệu nhiễu

-      Phân tích phổ được sử dụng để giám sát tín hiệu phát của UUT trên kênh vận hành sau khi có tín hiệu nhiễu đưa vào. Phân tích phổ cần quét để phát hiện khi có tín hiệu nhiễu;

-      Xác nhận các yêu cầu sau theo thủ tục trong 3.2.8.17:

·           UUT không phát trên tất cả kênh vận hành thiết lập ở bước 1 có nhiễu trong khoảng thời gian bằng giá trị lớn nhất của COT tương ứng với mức Lớp ưu tiên đang được sử dụng khi đo (xem Bảng 7, Bảng 8). UUT được phép phát tín hiệu điều khiển ngắn trên kênh vận hành như các yêu cầu tiếp theo;

·           Ngoài tín hiệu điều khiển ngắn, UUT không được phát tín hiệu khác khi có tín hiệu nhiễu;

·           Tín hiệu điều khiển ngắn phải thỏa mãn yêu cầu trong 2.6.3. Việc xác nhận đáp ứng đối với tín hiệu điều khiển ngắn có thể yêu cầu thay đổi thông số trên phân tích phổ;

-      Để xác nhận UUT không phát tín hiệu thường (ngoài báo hiệu ngắn) khi có nhiễu, thời gian giám sát phải bằng 60 s hoặc lâu hơn nếu cần phân đoạn thực hiện đo để đáp ứng yêu cầu về độ phân giải;

-      Khi hoàn thành phép đo và loại bỏ tín hiệu nhiễu, UUT có thể được bắt đầu phát trở lại trên kênh vận hành nhưng không cần xác nhận thêm các yêu cầu khác.

3.2.8.12.     Thiết bị LBE - Phép đo dẫn - Thủ tục xác nhận khả năng phát hiện tín hiệu RLAN khác trong trường hợp sử dụng nhiều kênh vận hành theo Tùy chọn 2

Bước 1: Thiết lập kết nối

-      UUT được cấu hình để hoạt động trênkênh vận hành là kênh ghép 40 MHz. Một trong hai kênh 20 MHz cấu thành kênh ghép được gọi là kênh vận hành chính (xem 2.6.2);

-      Xác nhận UUT đã bắt đầu phát trên các kênh vận hành.

Bước 2: Chèn tín hiệu nhiễu

-      Nhiễu (xem B.1.1) được bật;

-      Tần số và băng thông của nhiễu phải đảm bảo để chỉ chứa kênh vận hành 20 MHz phụ mà không chứa kênh vận hành 20 MHz chính;

-      Mức tín hiệu nhiễu tại đầu vào UUT phải bằng mức ED Threshold Level (TL) định nghĩa trong 2.6.2.

Bước 3: Xác nhận đáp ứng của thiết bị với tín hiệu nhiễu

-      Phân tích phổ được sử dụng để giám sát tín hiệu phát của UUT trên kênh vận hành sau khi có tín hiệu nhiễu đưa vào. Phân tích phổ cần quét để phát hiện khi có tín hiệu nhiễu;

-      Xác nhận các yêu cầu sau theo thủ tục trong 3.2.8.17:

·           UUT dừng phát trên kênh vận hành 20 MHz phụ có nhiễu trong khoảng thời gian bằng giá trị lớn nhất của COT tương ứng với mức Lớp ưu tiên đang được sử dụng khi đo (xem Bảng 7, Bảng 8). UUT được phép phát tín hiệu điều khiển ngắn trên kênh vận hành phụ như các yêu cầu tiếp theo;

·           Ngoài tín hiệu điều khiển ngắn, UUT không được phát tín hiệu khác trên kênh vận hành 20 MHz phụ khi có tín hiệu nhiễu;

·           Tín hiệu điều khiển ngắn phải thỏa mãn yêu cầu trong 2.6.3. Việc xác nhận đáp ứng đối với tín hiệu điều khiển ngắn có thể yêu cầu thay đổi thông số trên phân tích phổ;

-      Để xác nhận UUT không phát tín hiệu thường (ngoài báo hiệu ngắn) trên kênh vận hành 20 MHz phụ khi có nhiễu, thời gian giám sát phải bằng 60 s hoặc lâu hơn nếu cần phân đoạn thực hiện đo để đáp ứng yêu cầu về độ phân giải;

-      Khi hoàn thành phép đo và loại bỏ tín hiệu nhiễu, UUT có thể được bắt đầu phát trở lại trên kênh vận hành 20 MHz phụ nhưng không cần xác nhận thêm các yêu cầu khác.

3.2.8.13.     Thiết bị LBE - Phép đo dẫn - Cơ chế truy nhập kênh (Tùy chọn A)

Mục này quy định thủ tục đo kiểm để xác nhận cơ chế truy nhập kênh được UUT sử dụng.

Bước 1: tương tự bước 1 trong 3.2.8.9.

Bước 2:

-      Tương tự bước 2 trong 3.2.8.9;

-      Nếu UUT sử dụng theo Chú thích 1 trong Bảng 7, cần lưu ý:

·           Cấu hình nguồn lưu lượng thứ hai để lớn hơn lưu lượng lý thuyết của các thiết bị liên quan. Nguồn lưu lượng thứ hai sẽ được đưa vào bộ đệm của các thiết bị liên quan để thiết bị này luôn có dữ liệu ở hàng đợi (bộ đệm đầy) để đưa đến UUT;

·           Trong bài đo, thiết bị giám sát sẽ cấp phép một hoặc nhiều lần đối với từng thông số COT. Với mỗi COT, sẽ chỉ có duy nhất 1 khoảng lặng với độ dài ít nhất 100 ms được sử dụng.

Bước 3: Ghi tham số phát.

-      Ghi thời điểm bắt đầu và khoảng thời gian phát, thời điểm bắt đầu và thời gian nghỉ giữa các lần phát trên kênh vận hành;

-      Biểu diễn tx là thời điểm UUT bắt đầu, dx là khoảng thời gian kênh vận hành được sử dụng. Biểu diễn iy là thời điểm bắt đầu, gy là khoảng thời gian kênh vận hành không được sử dụng.

-      Hình 8 biểu diễn các thông số này.

 

 

Ie      ge >25 ms Kênh chiếm dụng ogồm nhiều đường truyền  gh >25 ms

                          Thời gian kênh chiếm dụng oy là (th+d- te)

 

 

Ie  t0            t0+d0              te       te+de tf        tf +dtg        tg+dg   th               th+dh                          t

Ie  ie          ie+ge      iif +gf           ig    ig+gg    ig       ig+gg             ih                           ih + g

 

 

Hình 8 -  Các khoảng thời gian

Bước 4: Đo khoảng thời gian rỗi và COT

-      Khoảng thời gian COT được định nghĩa bằng  với tc < th. nếu trong khoảng thời gian , tất các các khoảng thời gian gy kênh vận hành không có tín hiệu phát đều không lớn hơn 25 ms. Như được định nghĩa trong 2.6.2, trong mỗi COT có thể có một hoặc nhiều hơn lần UUT phát;

-      Sử dụng các giá trị ghi được ở bước 3, có thể xác định được các giá trị của các khoảng thời gian COT và các khoảng thời gian rỗi. Khoảng thời gian rỗi là khoảng thời gian giữa các lần phát khác nhau của UUT với giá trị lớn hơn 27 ms;

-      So với giá trị của khoảng thời gian rỗi (25 ms), giá trị 27 ms sử dụng trong phép đo này để tính đến sai số phép đo.   

Bước 5: Phân loại khoảng thời gian rỗi

-      Gọi k là số tự nhiên;

-      Gán tất cả các khoảng khoảng thời gian rỗi đến một trong số k + 1 nhóm chứa. Giá trị của k phụ thuộc mức Lớp ưu tiên được phép đo sử dụng. Mỗi nhóm chứa được biểu diễn bởi Bn, 0≤ n k:

·           Nếu Lớp ưu tiên bằng 1, k = 16 và các nhóm chứa được ký hiệu B0, …, B16;

·           Nếu Lớp ưu tiên bằng 2:

+          Nếu UUT sử dụng Chú thích 2 trong Bảng 7, k = 32 và các nhóm chứa được ký hiệu B0, …, B32;

+          Nếu UUT không sử dụng Chú thích 2 trong Bảng 7, k = 16 và các nhóm chứa được ký hiệu B0, …, B16;

·           Nếu Lớp ưu tiên bằng 3, k = 8 và các nhóm chứa được ký hiệu B0, …, B8;

·           Nếu Lớp ưu tiên bằng 4, k = 4 và các nhóm chứa được ký hiệu B0, …, B4;

-      Nếu Lớp ưu tiên bằng 1, nhóm chứa Bn được xác định như sau:

 

-      Nếu Lớp ưu tiên bằng 2, nhóm chứa Bn được xác định như sau:

·           Nếu UUT là thiết bị giám sát sử dụng Chú thích 2 trong Bảng 7:

 

·           Nếu UUT là thiết bị được giám sát hoặc UUT là thiết bị giám sát không sử dụng CHÚ THÍCH  2 trong Bảng 7:

 

-      Nếu Lớp ưu tiên là 3, nhóm chứa Bn được xác định như sau:

·           Nếu UUT là thiết bị được giám sát:

 

·           Nếu UUT là thiết bị giám sát:

 

-      Nếu Lớp ưu tiên là 4, nhóm chứa Bn được xác định như sau:

·           Nếu UUT là thiết bị được giám sát:

 

·           Nếu UUT là thiết bị giám sát:

 

Bước 6: Tính xác suất khoảng thời gian rỗi

-      Đặt H(Bn) là số lượng khoảng thời gian rỗi trong nhóm chứa Bn;

-      Đặt E là số lượng khoảng thời gian rỗi quan sát được. Khi đó:

 

-      Tính xác suất quan sát được như sau:

·           Đặt p(n) là xác suất khoảng thời gian rỗi có độ dài nhỏ hơn giới hạn trên của nhóm chứa Bn: p(n) = p(Idle Period< Giới hạn trên của Bn);

·           Với mỗi giá trị n, 0≤ n k:

 

-      Đánh giá UUT phù hợp với yêu cầu về xác suất lớn nhất như sau:

·           Nếu Lớp ưu tiên là 1, từng xác suất p(n) của khoảng thời gian rỗi trong từng nhóm chứa [B0, …, Bn] không được lớn hơn xác suất cực đại sau:

 

·           Nếu Lớp ưu tiên là 2, từng xác suất p(n) của khoảng thời gian rỗi trong từng nhóm chứa [B0, …, Bn] không được lớn hơn xác suất cực đại sau:

+          Nếu UUT sử dụng Chú thích 2 của Bảng 7:

 

+          Nếu UUT không sử dụng Chú thích 2 của Bảng 7:

 

+          Nếu UUT sử dụng Chú thích 1 của Bảng 7:

 

·           Nếu Lớp ưu tiên là 3, từng xác suất p(n) của khoảng thời gian rỗi trong từng nhóm chứa [B0, …, Bn] không được lớn hơn xác suất cực đại sau:

 

·           Nếu Lớp ưu tiên là 4, từng xác suất p(n) của khoảng thời gian rỗi trong từng nhóm chứa [B0, …, Bn] không được lớn hơn xác suất cực đại sau:

 

3.2.8.14.     Thiết bị LBE - Phép đo dẫn - Cơ chế truy nhập kênh (tùy chọn B)

Trong tùy chọn B, thay vì thực hiện đo trong 3.2.8.13, nhà sản xuất được phép khai báo sự phù hợp với các yêu cầu trong 2.6.2.

3.2.8.15.     Thiết bị LBE - Phép đo dẫn - COT lớn nhất (tùy chọn A)

Các bước dưới đây được sử dụng để đo kiểm xác nhận giá trị COT lớn nhất được UUT sử dụng.

Một kênh chiếm dụng bao gồm các thông tin phát từ UUT và có thể gồm cả thông tin phát từ các thiết bị liên quan. COT được xác định qua bước 4 trong 3.2.8.13. Các giá trị của COT phải được ghi trong Báo cáo đo.

Cấu hình ở bước 2 của 3.2.8.9sẽ cho phép UUT ở chế độ hoạt động có COT lớn nhất.

UUT phải thỏa mãn yêu cầu về giới hạn lớn nhất của COT dưới các điều kiện sau:

-      Nếu Lớp ưu tiên sử dụng là 1, các giá trị COT không lớn hơn 6 ms;

-      Nếu Lớp ưu tiên sử dụng là 2, các giá trị của COT không được lớn hơn các mức sau:

·           6 ms nếu UUT sử dụng Chú thích 1 trong Bảng 7;

·           10 ms nếu UUT sử dụng Chú thích 2 trong Bảng 7;

·           6 ms nếu UUT không sử dụng Chú thích 2 trong Bảng 7;

-      Nếu Lớp ưu tiên sử dụng là 3, các giá trị COT không lớn hơn 4 ms;

-      Nếu Lớp ưu tiên sử dụng là 4, các giá trị COT không lớn hơn 2 ms;

3.2.8.16.     Thiết bị LBE - Phép đo dẫn - COT lớn nhất (Tùy chọn B)

Trong tùy chọn B, thay vì thực hiện đo trong 3.2.8.15, nhà sản xuất được phép khai báo sự phù hợp với các yêu cầu trong 2.6.2.

3.2.8.17.     Thiết bị LBE - Phép đo dẫn - Thủ tục đo việc sử dụng kênh/tần số

Mục này đưa ra thủ tục đo chung để xác định có tín hiệu phát trên kênh vận hành đang đo hay không. Thủ tục này chỉ được sử dụng như một phần của thủ tục ở các mục đã nói ở trên.

Bước 1:

-      Đặt thông số máy phân tích phổ như sau:

·           Centre Frequency: Tần số trung tâm của kênh đang được kiểm tra;

·           Frequency Span: 0 Hz

·           RBW: khoảng 50 % băng thông kênh chiếm dụng (nếu không hỗ trợ đến mức này, sử dụng RBW cao nhất của máy);

·           VBW: ≥ RBW (nếu phân tích phổ không hỗ trợ, lựa chọn VBW lớn nhất có thể được thiết lập);

·           Detector Mode: RMS;

·           Sweep Time: > 2 x COT;

·           Sweep Points: ít nhất một điểm trong 1 ms;

·           Trace Mode: Clear/Write;

·           Trigger: Video hoặc RF/IF Power.

Bước 2:

-      Lưu dữ liệu đo vào file để thực hiện phân tích bằng máy tính bằng phần mềm thích hợp.

Bước 3:

-      Xác định các điểm dữ liệu cần phân tích bằng cách sử dụng ngưỡng phát hiện;

-      Đếm số điểm dữ liệu liên tiếp được xác định là kết quả của một lần truyền trên kênh đang được đánh giá và nhân số này với chênh lệch thời gian giữa hai điểm dữ liệu liên tiếp. Lặp lại việc này trên toàn bộ cửa sổ đo;

-      Khi đo các khoảng khoảng thời gian rỗi hoặc khoảng lặng, đếm số điểm dữ liệu liên tiếp từ một khoảng dừng phát trên kênh được đánh giá và nhân số điểm này với khoảng thời gian giữa hai điểm dữ liệu liên tiếp. Lặp lại việc này trên toàn bộ cửa sổ đo.

3.2.8.18.     Thiết bị LBE - Phép đo bức xạ

Công suất đầu ra của bộ tạo tín hiệu nhiễu phải thích hợp để công suất đầu vào ăng ten của UUT bằng mức ED Threshold Level(TL)  trong 2.6.2.

Khi thực hiện đo kiểm bằng phương pháp bức xạ trên UUT có ăng ten định hướng (bao gồm ăng ten thông minh và ăng ten có khả năng điều hướng), đường kết nối giữa UUT với thiết bị đi kèm và tín hiệu radar được tạo ra phải được sắp xếp trùng với hướng bức xạ lớn nhất của ăng ten được UUT sử dụng.

Cấu hình đo trong Phụ lục A và thủ tục đo liên quan trong Phụ lục B sẽ được sử dụng trong quá trình đo UUT. Thủ tục đo bức xạ cũng tương tự như đối với đo dẫn.

3.2.9.      Đặc tính chặn máy thu

3.2.9.1.        Điều kiện đo

Các phép đo được thực hiện trong điều kiện đo thường.

Kênh đo kiểm được sử dụng như trong 3.1.4.

UUT hoạt động ở chế độ vận hành bình thường.

Với thiết bị cần đo UUT có khả năng thay đổi tần số tự động (cấp phát kênh thích nghi), tính năng này phải được ngăn không sử dụng khi đo.

Nếu thiết bị có thể cấu hình để hoạt động với nhiều băng thông kênh chiếm dụng khác nhau, nhiều tốc độ dữ liệu khác nhau, phép đo yêu cầu sử dụng băng thông kênh chiếm dụng nhỏ nhất, tốc độ dữ liệu thấp nhất. Thiết bị phải đáp ứng yêu cầu về chất lượng trong 2.7và khai báo của nhà sản xuất trong 3.2.1. Các yêu cầu này phải được ghi trong Báo cáo đo.

3.2.9.2.        Phép đo dẫn

Với hệ thống sử dụng nhiều nhánh thu, chỉ một nhánh được lựa chọn để đo. Tất cả các nhánh khác đều bị ngăn.

Hình 9 trình bày sơ đồ đo được sử dụng với chỉ tiêu đặc tính chặn của máy thu. Các thiết bị liên quan có thể cần sử dụng phòng cách li hoặc không gian đặc biệt để chống lại các ảnh hưởng gây sai lệch kết quả đo.

 

 

Tùy chọn

Thay đổi với bước suy hao ≤ 1dB

Thiết bị giám sát thực hiện

Máy phân tích phổ

Bộ chía/ cộng

Máy tạo tín hiệu chặn

Khối báo hiệu hoặc thiết bị đồng hành

Phòng che chắn hoặc được che chắn

 

 

Hình 9 - Cấu hình đo đặc tính chặn máy thu

 

Đo kiểm tra đặc tính chặn máy thu được thực hiện như sau.

 

Bước 1:

-      UUT được đặt ở tần số hoạt động đầu tiên để đo.

Bước 2:

-      Bộ tạo tín hiệu chặn được đặt ở tần số đầu tiên như trong Bảng 9.

Bước 3:

-      Khi bộ tạo tín hiệu chặn được tắt, thiết lập kết nối giữa UUT và thiết bị liên quan theo sơ đồ đo trên Hinh 8. Điều chỉnh bộ suy hao theo từng bước 1 dB cho đến khi chất lượng yêu cầu vẫn được đảm bảo. Mức tín hiệu mong muốn tại đầu vào UUT là Pmin;

-      Tăng mức tối thiểu (Pmin) lên 6 dB để đưa đến đầu vào máy thu của UUT.

Bước 4:

-      Mức tín hiệu chặn tại đầu vào UUT được thiết lập bằng mức tương ứng trong Bảng 9. Ghi lại kết quả chất lượng đo và đánh giá UUT có đáp ứng được yêu cầu chất lượng trong 2.7hay không;

-      Nếu chất lượng vẫn được đảm bảo, tăng tiếp mức tín hiệu chặn cho đến khi chất lượng đạt mức thấp hơn mức tối thiểu. Mức tín hiệu chặn lớn nhất khi chất lượng không thấp hơn mức yêu cầu tối thiểu sẽ được ghi trong Báo cáo đo;

Bước 5:

-      Lặp lại bước 4 đối với từng tổ hợp tần số và mức trong Bảng 9.

Bước 6:

-      Lặp lại từ bước 2 đến bước 5 với UUT trên các tần số hoạt động khác để đánh giá chỉ tiêu đặc tính chặn của máy thu.

3.2.9.3.        Phép đo bức xạ

Khi thực hiện đo bức xạ cho thiết bị sử dụng ăng ten dành riêng, các phép đo được thực hiện riêng cho từng ăng ten được sử dụng.

Phép đo sử dụng sơ đồ đo ở Phụ lục A và thủ tục đo trong Phụ lục B kết hợp thủ tục tương tự như phép đo trong 3.2.9.2.

Mức tín hiệu gây chặn máy thu tại UUT được coi như mức trước ăng ten của UUT. UUT được sắp xếp và định vị sao cho hướng búp sóng chính của ăng ten trùng hướng bức xạ của tín hiệu chặn. Vị trí và hướng đặt UUT được ghi trong Báo cáo đo.

 

4.      QUY ĐỊNH VỀ QUẢN LÝ

Các thiết bị mạng nội bộ vô tuyến băng tần 5 GHz thuộc phạm vi điều chỉnh tại 1.1phải tuân thủ Quy chuẩn này.

5.      TRÁCH NHIỆM CỦA TỔCHỨC, CÁ NHÂN

Các tổ chức, cá nhân liên quan có trách nhiệm thực hiện chứng nhận và công bố hợp quy các thiết bị mạng nội bộ vô tuyến băng tần 5 GHz theo quy định về chứng nhận và công bố hợp quy đối với sản phẩm hàng hóa chuyên ngành công nghệ thông tin và truyền thông và chịu sự kiểm tra của cơ quan quản lý nhà nước theo các quy định hiện hành.

6.      TỔ CHỨC THỰC HIỆN

 

6.1. Cục Viễn thông, Cục Tần số vô tuyến điện và các Sở Thông tin và Truyền thông có trách nhiệm tổ chức hướng dẫn, triển khai quản lý các thiết bị mạng nội bộ vô tuyến băng tần 5 GHz theo Quy chuẩn này.

6.2. Quy chuẩn này được áp dụng thay thế cho Quy chuẩn kỹ thuật quốc gia QCVN 65:2013/BTTTT, “Quy chuẩn kỹ thuật quốc gia về thiết bị truy nhập vô tuyến băng tần 5 GHz”.

6.3. Trong trường hợp các quy định nêu tại Quy chuẩn này có sự thay đổi, bổ sung hoặc được thay thế, việc thực hiện theo quy định tại văn bản mới.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phụ lục A

(Quy định)

Hệ thống đo kiểm và bố trí đo bức xạ

A.1. Tổng quan

Phụ lục này giới thiệu 3 hệ thống đo kiểm (test sites) phổ biến nhất và bộ ghép đo được sử dụng trong phép đo bức xạ theo quy định của quy chuẩn này.

·      Hệ thống đo kiểm ngoài trời (OATS)

·      Phòng bán hấp thụ (SAR)

·      Phòng hấp thụ hoàn toàn (FAR)

·      Bộ ghép đo cho phép đo tương đối

·      Tín hiệu nhiễu được sử dụng các bài kiểm tra khả năng thích ứng

·Tín hiệu nhiễu được sử dụng cho các bài kiểm tra khả năng thích ứng

·Signal noise used for adaptability tests

·Giao thoa tín hiệu được sử dụng để thử nghiệm Adaptivity

·Interference signal used for Adaptivity . testing

·Can't load full results

·Try again

·Retrying...

·Retrying...

A.2. Vị trí đo bức xạ

A.2.1. Hệ thống đo kiểm ngoài trời (OATS)

Hệ thống đo kiểm ngoài trời gồm có một bàn xoay ở một đầu và một ăng ten có thể thay đổi được chiều cao so với đầu kia, cả hai được đặt phía trên một mặt đáy, trong trường hợp lý tưởng mặt đáy này là dẫn điện tốt và mở rộng vô hạn. Thực tế, có thể tạo được một mặt đáy dẫn điện tốt, nhưng không thể tạo ra được mặt đáy vô hạn. Hình A.1 mô tả một Hệ thống đo kiểm ngoài trời điển hình.

 

Ăng ten thay thế (Ăng ten phụ)

 

 

 

 

Độ dài đo

Mâm quay

Cột ăng ten quay

Ăng ten đo

Mặt đáy

 

 

Hình A.1- Hệ thống đo kiểm ngoài trời điển hình

 

Mặt phẳng đất tạo ra đường phản xạ. Khi đó ăng ten thu sẽ thu được tín hiệu từ đường truyền trực tiếp và đường phản xạ. Việc kết hợp các đường tín hiệu bị ảnh hưởng bởi độ cao đặt ăng ten do pha đường truyền phản xạ bị thay đổi.

Bàn xoay ăng ten cho phép thay đổi độ cao so với bề mặt đất từ 1 đến 4 m sao cho vị trí đo ăng ten đặt tối ưu, đảm bảo thông tin giữa các ăng ten trong hệ thống đo.

Bàn xoay ăng ten phải có khả năng xoay tối đa 3600 trong mặt phẳng ngang khi được sử dụng để đo UUT đặt ở vị trí cao hơn bề mặt đất 1,5 m.

Khoảng cách giữa các điểm đặt ăng ten sẽ được trình bày trong A.2. Thông tin khoảng cách sẽ được ghi trong Báo cáo kết quả đo.

A.2.2.  Phòng bán hấp thụ (phòng câm/phòng không phản xạ)

Phòng có kết cấu đặc biệt với các vật liệu bao bọc phía trong có khả năng hấp thụ sóng vô tuyến, triệt tiêu hiện tượng phản xạ. Bên trong phòng câm, thiết bị đo bao gồm hệ thống ăng ten ở một phía và bàn xoay ở một phía, có thể dùng để gắn thiết bị cần đo như minh họa trong Hình A.2.

Vật liệu và cấu tạo đặc biệt của phòng câm làm giảm thiểu nhiễu nền và ảnh hưởng của các yếu tố khác đến kết quả đo.

Khoảng cách đặt thiết bị đo và kích thước phòng câm phải tuân thủ yêu cầu trong A.2.

 

 

Ăng ten đo

Text Box: 1 m đến 4 m

Mâm quay

  Mặt đáy

Độ dài đo

Vật liệu hấp thụ sóng vô tuyến

Mâm quay

 

Hình A.2- Phòng không phản xạ điển hình

A.2.3. Phòng hấp thụ hoàn toàn (FAR)

Hộp kín, thường được che chắn, những bức tường, sàn nhà và trần nhà bên trong được che phủ bởi vật liệu hấp thụ sóng vô tuyến. Phòng thường gồm có cột ăng ten ở một đầu và bàn xoay ở đầu kia. Như mô tả trong Hình A.3.

 

 

 

Giá đỡ ăng ten

Giá đỡ ăng ten

Khoảng cách đo kiểm

Mâm quay

Vật liệu hấp thụ sóng vô tuyến

Ăng ten đo kiểm

 

Hình A.3 - Phòng hấp thụ điển hình

Vật liệu che chắn phòng và vật liệu hấp thụ sóng vô tuyến tạo nên môi trường được kiểm soát cho những mục đích đo kiểm. Loại phòng đo này cố gắng mô phỏng điều kiện không gian tự do.

Vật liệu che chắn cung cấp không gian đo kiểm với việc giảm các mức của can nhiễu từ những tín hiệu xung quanh và những tác động bên ngoài khác, trong khi vật liệu hấp thụ sóng vô tuyến giảm thiểu những phản xạ không mong muốn từ các bức tường và trần nhà là những thứ có thế ảnh hưởng đến các phép đo.Vật liệu che chắn phải đủ để ngăn cản nhiễu. Vật liệu che chắn phải đảm bảo loại bỏ nhiễu từ môi trường bên ngoài, che chắn bất kỳ tín hiệu được đo

Bàn xoay có thể quay 3600 trong mặt phẳng ngang và nó được sử dụng để đỡ mẫu đo kiểm (EUT) ở độ cao thích hợp (ví dụ 1 m) phía trên mặt vật liệu hấp thụ.

Khoảng cách đo và kích thước buồng cách ly tối thiểu có thể được tìm thấy trong A.2.4. Khoảng cách sử dụng trong đo kiểm thực tế phải được ghi lại cùng với kết quả đo.

A.2.4.  Khoảng cách đo

Khoảng cách để thực hiện đo UUT được lựa chọn sao cho UUT ở vị trí khu vực trường xa của ăng ten máy đo. Khoảng cách nhỏ nhất giữa thiết bị cần đo (UUT) và ăng ten đo là rm >> D2/ λ,  trong đó:

            : bước sóng, m;

            rm: khoảng cách nhỏ nhất giữa UUT và ăng ten thu, m;

            D: Kích thước lớn nhất của khẩu độ (độ mở) vật lý của ăng ten lớn nhất được cài đặt để đo, tính bằng m..

 là khoảng cách giữa ranh giới bên ngoài của phát xạ trường gần (vùng Fresnel) và ranh giới bên trong của của phát xạ trường xa (vùng Fraunhofer), tính bằng m và cũng được gọi là khoảng cách Rayleigh.

Với các phép đo không thể đảm bảo khoảng cách yêu cầu, cần phải ghi những yếu tố này trong Báo cáo đo.

A.3.  Ăng ten

A.3.1. Ăng ten đo

Ăng ten đo được sử dụng để đo sóng từ UUT và từ các ăng ten phụ. Nếu thiết bị cần đo phần thu, ăng ten đo được sử dụng để phát tín hiệu.

Ăng ten đo được gắn vào hệ thống giá đỡ và có thể sử dụng với phân cực ngang hoặc phân cực thẳng đứng. Ngoài ra, với bài đo ngoài trời, độ cao ăng ten phải đủ lớn, khoảng từ 1 đến 4 m.

Tùy thuộc dải tần cần đo, ăng ten cần được lựa chọn để đáp ứng đầy đủ yêu cầu về thu/phát trong dải tần đó.

A.3.2.  Ăng ten phụ

Ăng ten phụ được sử dụng để thay cho UUT trong một số phép đo bổ sung.

Ăng ten phụ được chọn để đáp ứng đầy đủ yêu cầu về thu/phát trong dải tần cần đo.

Điểm đặt ăng ten phụ trùng với vị trí tâm của UUT nếu UUT dùng ăng ten tích hợp hoặc vị trí kết nối ăng ten ngoài vào UUT nếu UUT dùng ăng ten rời.

Khoảng cách của điểm thấp nhất của ăng ten phụ đến mặt đất không nhỏ hơn 30 cm. Trước khi sử dụng, ăng ten phụ phải được căn chuẩn so với ăng ten tham chiếu. Ăng ten tham chiếu ở dải tần dưới 1 GHz là ăng ten lưỡng cực nửa bước sóng và ăng ten tham chiếu ở dải tần trên 1 GHz là ăng ten bức xạ đẳng hướng.

A.4. Bộ ghép đo

A.4.1. Giới thiệu

Các phép đo dẫn có thể được áp dụng cho thiết bị cung cấp đầu kết nối ăng ten tạm thời, ví dụ tới máy phân tích phổ.

Trong trường hợp ăng ten tích hợp không có đầu kết nối ăng ten thì bộ ghép đo được sử dụng để thực hiện các phép đo tương đối tại điều kiện nhiệt độ tới hạn.

A.4.2. Mô tả bộ ghép đo

Bộ ghép đo sẽ cung cấp phương tiện đấu nối tới đầu ra của tần số vô tuyến.

Trở kháng danh định của kết nối bên ngoài tới bộ ghép đo phải là 50 Ω tại các tần số hoạt động của thiết bị.

Đặc điểm hoạt động của bộ ghép đo dưới các điều kiện bình thường và tới hạn phải là:

a)     Suy hao ghép nối phải được giới hạn để đảm bảo một dải hoạt động đầy đủ về thiết lập;

b)     Sự thay đổi suy hao ghép nối với tần số sẽ không gây ra lỗi quá ± 2 dB;

c)     Thiết bị ghép nối không bao gồm bất kỳ phần tử không tuyến tính.

A.4.3. Sử dụng bộ ghép đo cho các phép đo tương đối.

Bước 1 đến bước 4 dưới đây mô tả thủ tục thực hiện các phép đo tương đối cho các yêu cầu này trong trường hợp đo kiểm cần phải được lặp lại tại các nhiệt độ khác nhau:

Bước 1:

Thực hiện đo kiểm dưới điều kiện bình thường trong một vị trí đo đối với đo bức xạ như được mô tả trong phụ lục A.2. Kết quả là giá trị tuyệt đối được ghi lại.

Bước 2:

Đặt thiết bị với bộ ghép đo trong phòng nhiệt độ. Thực hiện đo kiểm tương tự tại điều kiện bình thường trong môi trường này và bình thường hóa các thiết bị đo để có được những giá trị tương tự như trong bước 1.

Bước 3:

Cần thận các khớp nối của bộ ghép đo vẫn không thay đổi trong suốt quá trình đo kiểm.

Bước 4:

Phép đo được lặp lại cho các điều kiện nhiệt độ tới hạn. Do việc bình thường thực hiện ở bước 2, các giá trị thu được là kết quả đo cho yêu cầu này.

A.5. Hướng dẫn khi đo bức xạ

Mục này mô tả chi tiết những thủ tục, cách bố trí thiết bị đo và việc kiểm tra phải được thực hiện trước bất kỳ phép đo bức xạ. Những thủ tục này là phổ biến cho các loại Hệ thống đo kiểm được mô tả trong phụ lục này.

Các UUT được đặt ra hay gắn trên một giá đỡ không dẫn điện.

A.5.1. Bộ nguồn cho UUT chỉ dùng pin

Trong trường hợp UUT chỉ dùng pin việc ưu tiên là để thực hiện đo kiểm bằng cách sử dụng pin của UUT.

Việc đo kiểm phải có các dây dẫn nguồn được nối tới những đầu cấp nguồn của UUT (và được kiểm tra bằng vôn kế hiện số) và được cách ly về điện với phần còn lại của thiết bị, có thể bằng cách dán băng keo lên các điểm tiếp xúc của nó.

Đối với thiết bị được cấp nguồn bằng pin, dây dẫn điện phải được kết nối với các đầu nối nguồn cung cấp của UUT (và được theo dõi bằng vôn kế kỹ thuật số) nhưng pin vẫn ở trạng thái hiện diện, được cách ly về điện với phần còn lại của thiết bị, có thể bằng cách dán băng keo lên các điểm tiếp xúc của nó.

For battery powered equipment, the power lead should be connected to the UUT's supply terminals (and monitored with a digital voltmeter) but the battery remains present, isolated. electrically with the rest of the device, possibly by taping its contacts.

Đối với thiết bị chạy bằng pin, dẫn điện phải được kết nối với thiết bị đầu cuối cung của UUT (và giám sát bằng một vôn kế kỹ thuật số) nhưng pin nên vẫn còn hiện tại, cô lập điện từ phần còn lại của thiết bị, có thể bằng cách đặt băng qua địa chỉ liên lạc của nó.

For battery powered equipment, the conduction should be connected to the supply terminal of the UUT (and monitored with a digital voltmeter) but the battery should remain current, isolating power from the rest of the battery. device, possibly by putting the tape across its contacts.

Can't load full results

Try again

Retrying...

Retrying...

Sự có mặt những cáp tải điện này có thể ảnh hưởng đến phép đo. Vì lý do này, chúng cần phải được làm "trong suốt" như là tránh xa phép đo liên quan (ví dụ dây dẫn có thể xoắn với nhau, nạp tải với các hạt ferrite …).

A.5.2. Bố trí vị trí

Cáp tới ăng ten đo kiểm và ăng ten thay thế phải được bố trí phù hợp để giảm thiểu tác động tới phép đo.

A.6. Ghép nối các tín hiệu

Sự hiện diện của các dây dẫn đo (không kết hợp với UUT để hoạt động bình thường) trong trường bức xạ có thể gây ra nhiễu cho trường này dẫn đến làm tăng độ không đảm bảo đo. Những nhiễu này có thể được giảm thiểu bằng cách sử dụng các phương pháp ghép nối phù hợp, cung cấp cách ly tín hiệu và tối thiểu trường nhiễu (ví dụ ghép quang học).

A.7. Tín hiệu nhiễu được sử dụng các bài kiểm tra khả năng thích ứng

A.7.1.  Nhiễu trắng Gauss (AWGN - Additive White Gaussian Noise)

Nhiễu AWGN được sử dụng là nhiễu liên tục (tần suất 100 %) có băng thông 20 MHz.

-      Khi đo khả năng phát hiện tín hiệu RLAN ở chế độ vận hành đa kênh theo Tùy chọn 1, AWGN sẽ xuất hiện trên tất cả các kênh được sử dụng. Tuy nhiên, nếu thực hiện đo tuần tự trên các kênh, AWGN sẽ chỉ xuất hiện trên kênh vận hành được đo;

-      Khi đo khả năng phát hiện tín hiệu RLAN ở chế độ vận hành đa kênh theo Tùy chọn 2, nhiễu AWGN chỉ xuất hiện ở kênh vận hành phụ.

A.7.2.  Tín hiệu đo OFDM

Tín hiệu đo OFDM bao gồm chuỗi các symbol OFDM liên tục được định nghĩa trong mục 17 của tài liệu IEEE 802.11™-2016. Như vậy, tín hiệu đo OFDM không chứa thành phần mào đầu OFDM PHY như trong 17.3.3 của tài liệu IEEE 802.11™-2016.

-      Khi đo khả năng phát hiện tín hiệu RLAN ở chế độ vận hành đa kênh theo Tùy chọn 1, tín hiệu đo OFDM sẽ xuất hiện trên tất cả các kênh được sử dụng. Tuy nhiên, nếu thực hiện đo tuần tự trên các kênh, tín hiệu đo OFDM sẽ chỉ xuất hiện trên kênh vận hành được đo;

-      Khi đo khả năng phát hiện tín hiệu RLAN ở chế độ vận hành đa kênh theo Tùy chọn 2, tín hiệu đo chỉ xuất hiện ở kênh vận hành phụ.

A.7.3.  Tín hiệu đo LTE

Tín hiệu đo LTE là tín hiệu liên tục có băng thông 20 MHz được định nghĩa trong 6.1.1.1 của tài liệu ETSI TS 136 141.

-      Khi đo khả năng phát hiện tín hiệu RLAN ở chế độ vận hành đa kênh theo Tùy chọn 1, tín hiệu đo LTE sẽ xuất hiện trên tất cả các kênh được sử dụng. Tuy nhiên, nếu thực hiện đo tuần tự trên các kênh, tín hiệu đo LTE sẽ chỉ xuất hiện trên kênh vận hành được đo;

-      Khi đo khả năng phát hiện tín hiệu RLAN ở chế độ vận hành đa kênh theo Tùy chọn 2, tín hiệu đo chỉ xuất hiện ở kênh vận hành phụ.

A.7.4.  Thủ tục đánh giá tín hiệu đo

Tín hiệu đo được kiểm tra theo thủ tục dưới đây.

Nối bộ tạo tín hiệu nhiễu với máy phân tích phổ. Đặt các thông số sau trên phân tích phổ:

-      Centre Frequency: Tần số trung tâm danh định của tín hiệu nhiễu;

-      Span: 2 × băng thông danh định của tín hiệu nhiễu;

-      Resolution BW: xấp xỉ 1 % băng thông danh định của tín hiệu nhiễu;

-      Video BW: 3 × Resolution BW

-      Sweep Points: 2 × Span / Resolution BW. Nếu phân tích phổ không hỗ trợ đến số điểm quét yêu cầu, có thể thực hiện phân đoạn băng thông và đo từng đoạn;

-      Detector: Peak

-      Trace Mode: Averaging

-      Number of sweeps: Thích hợp để kết quả đo ổn định;

-      Sweep time: Auto

Băng thông 99 % (băng thông chứa đến 9 9% công suất) của tín hiệu nhiễu phải nằm trong khoảng từ 80 % đến 100 % băng thông kênh danh định của UUT. Để đảm bảo độ ổn định (phẳng) của nhiễu, băng thông 4 dB (băng thông gồm các điểm chênh lệch không quá 4 dB so với mức đỉnh) của tín hiệu nhiễu (bỏ qua biến động DC tại tần số trung tâm) phải nằm trong ít nhất 80 % băng thông 99 % của tín hiệu nhiễu.

Khi đo khả năng phát hiện tín hiệu RLAN ở chế độ vận hành đa kênh theo Tùy chọn 1, yêu cầu trên áp dụng đối với tín hiệu nhiễu tương ứng tất cả các kênh được sử dụng. Tuy nhiên, nếu thực hiện đo tuần tự trên các kênh, yêu cầu trên chỉ áp dụng với tín hiệu nhiễu tương ứng kênh vận hành được đo.

Khi đo khả năng phát hiện tín hiệu RLAN ở chế độ vận hành đa kênh theo Tùy chọn 2, yêu cầu trên chỉ áp dụng cho tín hiệu nhiễu tương ứng kênh vận hành phụ.

Mật độ phổ công suất của tín hiệu nhiễu được kiểm tra bằng cách thiết lập thông số phân tích phổ như sau:

-      Centre Frequency: Tần số trung tâm danh định của tín hiệu nhiễu;

-      Span: Băng thông danh định của tín hiệu nhiễu;

-      Resolution BW: 1 MHz

-      Video BW: 3 × Resolution BW

-      Filter: Channel

-      Detector: RMS

-      Trace Mode: Clear Write

-      Number of sweeps: Single

-      Sweep time: 1 s (tốc độ quét có thể giảm sao cho không ảnh hưởng đến giá trị RMS của tín hiệu cần đo).

Giá trị đỉnh đo được ở trên là mật độ phổ công suất của tín hiệu nhiễu.

Khi kết hợp nhiều tín hiệu nhiễu để kiểm tra khả năng hoạt động đa kênh, các phép đo kiểm tra tín hiệu đo nói trên được thực hiện trên từng băng thông kênh danh định trong các kênh được sử dụng.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phụ lục B                                                                                                                                        (Quy định)

Các thủ tục đo đối với phép đo bức xạ

B.1. Tổng quan

Phụ lục này đưa các thủ tục chung đối với các phép đo bức xạ bằng cách sử dụng các hệ thống đo kiểm và bố trí đo được mô tả trong Phụ lục A.

Tốt nhất, các phép đo bức xạ phải được thực hiện trong phòng FAR, như mô tả trong B.3. Đo bức xạ trong OATS hoặc SAR được mô tả trong B.2.

B.2. Đo bức xạ trong OATS hoặc SAR

B.2.1.  Đo ngoài trời OATS

Đo bức xạ được thực hiện bằng cách sử dụng ăng ten đo và ăng ten thay thế trong không gian được trình bày trong Phụ lục A. Cấu hình và hiệu chuẩn thiết bị đo được thực hiện theo thủ tục sau.

UUT và ăng ten được chỉnh hướng sao cho công suất phát xạ thu được từ UUT là lớn nhất. Vị trí đặt và hướng được ghi trong Báo cáo đo.

a)        Ăng ten đo (thiết bị 2 trong hình B.1) phải được định hướng ban đầu là phân cực đứng trừ khi có các chỉ định khác và UUT (thiết bị 1 trong hình C1) được đặt trên giá đỡ ở vị trí chuẩn của nó và được bật lên;

b)        Thiết bị đo (thiết bị 3 trong hình B.1) phải được kết nối tới ăng ten đo (thiết bị 2 trong hình B.1) như trình bày trong hình B.1;

c)         UUT được xoay 3600 quanh trục thẳng đứng cho đến khi thu được mức tín hiệu lớn nhất;

d)        Ăng ten đo lại được điều chỉnh nâng lên hoặc hạ xuống trong khoảng độ cao quy định cho tới khi thu được mức tín hiệu lớn nhất. Ghi lại giá trị này;

e)        Phép đo này được lặp lại đối với phân cực ngang.

 

 

 

1 - Thiết bị cần đo

2 - Ăng ten đo

3 - Máy phân tích phổ hoặc máy thu đo

 

Hình B.1 -  Sơ đồ đo bức xạ

B.2.2.  Đo trong phòng câm

Đo trong phòng câm được thiết lập và căn chỉnh tương tự như với đo ngoài trời trong B.2.1 nhưng bỏ qua bước căn chỉnh độ cao ăng ten đo.

B.2.3.  Đo thay thế

Đề xác định giá trị đo kiểm tuyệt đối, phương pháp đo thay thế như được mô tả trong các bước dưới đấy phải được thực hiện:

1)        Thay thế UUT với ăng ten thay thế như được mô tả là thiết bị 1 trong hình B.1. Ăng ten đo và ăng ten thay thế là phân cực đứng;

2)        Kết nối máy tạo tín hiệu với ăng ten thay thế và điều chỉnh đến tần số đo kiểm tra;

3)        Nếu OATS hoặc SAR được sử dụng, ăng ten đo được nâng lên hoặc hạ xuống để đảm bảo tín hiệu thu được là lớn nhất;

4)        Sau đó công suất của máy tạo tín hiệu được điều chỉnh cho tới khi cùng mức thu được như đã ghi từ UUT;

5)        Công suất bức xạ bằng công suất cung cấp bởi máy tạo tín hiệu cộng với tăng ích của ăng ten thay thế trừ đi suy hao cáp (theo dB);

6)        Phép đo được lặp lại đối với phân cực ngang.

Với các phòng đo hay không gian đo gắn cố định ăng ten đo và cho phép điều chỉnh vị trí UUT, có thể sử dụng các giá trị hiệu chuẩn lắp đặt của phòng đo hay không gian đo để thay thế cho các bước thực hiện nói trên.

B.3.  Hướng dẫn đối với đo khả năng thích nghi

B.3.1. Cấu hình đo

Hình B.2 biểu diễn cấu hình được sử dụng trong phép đo cơ chế truy nhập của UUT. Để tránh ảnh hưởng của tín hiệu khác và môi trường đến kết quả phép đo, việc thực hiện đo được thực hiện trong phòng câm.

 

Thiết bị đồng hành

Máy phát        tín hiệu

 

 

Hình B.2 -  Cấu hình đo truy nhập thích nghi

 

B.3.2.  Hiệu chuẩn cấu hình đo

Trước khi thực hiện đo, cần thực hiện hiệu chuẩn cấu hình đo.

Hình B.B.3 biểu diễn sơ đồ hiệu chuẩn cấu hình đo trong Hình B.B.2 bằng cách sử dụng ăng ten thay thế và phân tích phổ. Việc hiệu chuẩn được thực hiện để đảm bảo mức tín hiệu nhiễu tại đầu vào ăng ten thay thế tương ứng với mức sẽ được sử dụng trong phép đo dẫn khi sử dụng ăng ten tăng ích 0 dBi để đưa đến UUT.

Với phòng đo có ăng ten cố định và cho phép thay đổi được vị trí UUT, có thể sử dụng các giá trị hiệu chuẩn do phòng đo cung cấp.

 

Ăng ten

thay thế

Máy phát        tín hiệu

Ăng ten loa

Khoảng cách đo

Máy phân tích phổ

 

 

Hình B.3 -  Cấu hình hiệu chuẩn phép đo bức xạ cơ chế truy nhập thích nghi

B.3.3.  Phương pháp đo

Thủ tục đo bao gồm các bước sau:

- Thay thế ăng ten thay thế với UUT, thực hiện một lần hiệu chuẩn.

- UUT phải được định vị để có công suất e.i.r.p. lớn nhất hướng về phía ăng ten loa.

CHÚ THÍCH : vị trí thiết lập được ghi trong Báo cáo đo.

B.4.  Hướng dẫn đo kiểm đặc tính chặn của máy thu

B.4.1.  Cấu hình đo

Hình B.4 minh họa cấu hình đo để việc bố trí được sử dụng để thực hiện đo bức xạ khả năng chặn máy thu. Để đảm bảo kết quả đo chính xác, không bị tác động của môi trường bên ngoài, bài đo được thực hiện trong phòng SAR, FAR.

 

 

Hình B.4 -  Cấu hình đo đặc tính chặn máy thu bằng phương pháp đo bức xạ

B.4.2.  Hiệu chuẩn cấu hình đo

Trước khi thực hiện đo, cần thực hiện hiệu chuẩn cấu hình đo. Hình B.5 biểu diễn sơ đồ hiệu chuẩn cấu hình đo trong Hình B.4 bằng cách sử dụng ăng ten thay thế và phân tích phổ. Việc hiệu chuẩn được thực hiện để đảm bảo mức tín hiệu nhiễu tại đầu vào ăng ten thay thế tương ứng với mức sẽ được sử dụng trong phép đo dẫn khi sử dụng ăng ten tăng ích 0 dBi để đưa đến UUT.

Với phòng đo có ăng ten cố định và cho phép thay đổi được vị trí UUT, có thể sử dụng các giá trị hiệu chuẩn do phòng đo cung cấp.

 

 

Máy tạo        tín hiệu chặn

Ăng ten

thay thế

Khoảng cách đo

Ăng ten loa

Máy phân tích phổ

 

Hình B.5 -  Cấu hình hiệu chuẩn đo đặc tính chặn máy thu

B.4.3.  Phương pháp đo

Thủ tục đo bao gồm các bước sau:

·      Thay thế ăng ten thay thế với UUT, thực hiện một lần hiệu chuẩn.

·      UUT phải được định vị để có công suất e.i.r.p. lớn nhất hướng về phía ăng ten loa.

 

CHÚ THÍCH : vị trí thiết lập được ghi trong Báo cáo đo.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phụ lục C

(Quy định)

Mã HS thiết bị truy nhập vô tuyến băng tần 5 GHz 

 

TT

Tên sản phẩm, hàng hóa theo QCVN

Mã số HS

Mô tả sản phẩm, hàng hóa

01

Thiết bị truy nhập vô tuyến băng tần 5 GHz có công suất bức xạ đẳng hướng tương đương từ 60 mW trở lên

8517.62.51

Thiết bị thu-phát sóng WiFi sử dụng trong mạng nội bộ không dây ở băng tần 5 GHz (Modem WiFi, bộ phát WiFi) có công suất bức xạ đẳng hướng tương đương từ 60 mW trở lên, có hoặc không tích hợp một hoặc nhiều chức năng sau:

- Thu phát vô tuyến sử dụng kỹ thuật điều chế trải phổ trong băng tần 2,4 GHz;

- Đầu cuối thông tin di động GSM;

- Đầu cuối thông tin di động W-CDMA FDD;

- Đầu cuối thông tin di động E-UTRA FDD (4G/LTE);

- Đầu cuối thông tin di động thế hệ thứ năm (5G);

- Thu phát vô tuyến cự ly ngắn khác.

8525.80.40

Flycam (camera truyền hình, camera kỹ thuật số và camera ghi hình ảnh được gắn trên thiết bị bay) sử dụng công nghệ điều khiển từ xa, truyền hình ảnh bằng sóng vô tuyến điều chế trải phổ trong băng tần 5 GHz và có công suất bức xạ đẳng hướng tương đương từ 60 mW trở lên.

8802.20.90

UAV/Drone (phương tiện bay được điều khiển từ xa, có thể tích hợp thiết bị camera truyền hình, camera kỹ thuật số và camera ghi hình ảnh) sử dụng công nghệ điều khiển từ xa, truyền hình ảnh bằng sóng vô tuyến điều chế trải phổ trong băng tần 5 GHz và có công suất bức xạ đẳng hướng tương đương từ 60 mW trở lên.

 

 

 

 

Thư mục tài liệu tham khảo

 

[1] Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).

[2] FCC PART 15.247: Code of Federal Regulations (USA), Title 47 Telecommunications, Chapter 1 Federal Communications Commission, Part 15 Radio Frequency Devices, Subpart C – Intentional Radiators, §15.247 Operation within the bands 902 – 928 MHz, 2400 – 2483.5 MHz, and 5725 – 5850 MHz.

[3] FCC PART 15.407: Code of Federal Regulations (USA), Title 47 Telecommunications, Chapter 1 Federal Communications Commission, Part 15 Radio Frequency Devices, Subpart E - Unlicensed National Information Infrastructure Devices, §15.407 General technical requirements.

[4] CISPR 16-1: "Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus".

[5] ECC/DEC(04)08: "ECC Decision of 12 November 2004 on the harmonised use of the 5 GHz frequency bands for the implementation of Wireless Access Systems including Radio Local Area Networks (WAS/RLANs)".

[6] ETSI EN 301 489: "Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services".

[7] ITU-R M.1652: Dynamic frequency selection (DFS) in wireless access systems including radio local area networks for the purpose of protecting the radiodetermination service in the 5 GHz band.

[8] ETSI EN 301 893 V2.1.1 (2017-05): 5 GHz RLAN;Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU.

 